Hydrogen is considered to be a hazardous substance. Hydrogen sensors can be used to detect the concentration of hydrogen and provide an ideal monitoring means for the safe use of hydrogen energy. Hydrogen sensors need to be highly reliable, so fault identification and diagnosis for gas sensors are of vital practical significance. However, traditional machine learning methods for fault diagnosis are based on features extracted by experts, prior knowledge requirements and the sensitivity of system changes. In this study, a new convolutional neural network (CNN) using the random forest (RF) classifier is proposed for hydrogen sensor fault diagnosis. First, the 1-D time-domain data of fault signals are converted into 2-D gray matrix images; this process does not require noise suppression and no signal information is lost. Secondly, the features of the gray matrix images are automatically extracted by using a CNN, which does not rely on expert experience. Dropout and zero-padding are used to optimize the structure of the CNN and reduce overfitting. Random forest, which is robust and has strong generalization ability, is introduced for the classification of gas sensor signal modes, in order to obtain the final diagnostic results. Finally, we design and implement a prototype hydrogen sensor array for experimental verification. The accuracy of fault diagnosis in hydrogen sensors is 100% under noisy environment with the proposed method, which is superior of CNN without RF and other methods. The results show that the proposed CNN with RF method provides a good solution for hydrogen sensor fault diagnosis.
The fault safety monitoring of hydrogen sensors is very important for their practical application. The precondition of traditional machine learning methods for sensor fault diagnosis is that enough fault data with the same distribution and feature space under the same working environment must exist. Widely used fault diagnosis methods are not suitable for real working environments because they are easily complicated by environmental conditions such as temperature, humidity, shock, and vibration. Under the influence of such complex conditions, the acquisition of sensor fault data is limited. In order to improve fault diagnosis accuracy under complex environmental conditions, a novel method of transfer learning (TL) with LeNet-5 is proposed in this paper. Firstly, LeNet-5 is applied to learn the features of the data-rich datasets of gas sensor faults in a normal environment and to adjust the parameters accordingly. The parameters of the LeNet-5 are transferred from the task in the normal environment to a task in a complex environment by using the TL method. Then, the migrated LeNet-5 is used for the fault diagnosis of gas sensors with a small amount of fault data in a complex environment. Finally, a prototype hydrogen sensor array is designed and implemented for experimental verification. The gas sensor fault diagnosis accuracy of the traditional LeNet-5 was 88.48 ± 1.04%, while the fault diagnosis accuracy of TL with LeNet-5 was 92.49 ± 1.28%. The experimental results show that the method adopted presents an excellent solution for the fault diagnosis of a hydrogen sensor using a small quantity of fault data obtained under complex environmental conditions.
1 September 2021 in Review of Scientific Instruments
The fault diagnosis of hydrogen sensors is of great significance. However, it is difficult to collect data samples for some modes of hydrogen sensor signals, so the data samples may be unbalanced, which can seriously affect the fault diagnosis results. In this paper, we present a novel convolutional neural network (CNN)-based deep convolutional generative adversarial network (DCG) method (DCG–CNN) for gas sensor fault diagnosis. First, we transform the 1D fault signals of the gas sensor into 2D gray images for end-to-end conversion with no signal data information loss. Second, we use the DCG to enrich the 2D gray images of small fault data samples, which results in balanced sensor fault datasets. Third, we use the CNN method to improve the accuracy of fault diagnosis. In order to understand the internal mechanism of the CNN, we further visualize the learned feature maps of fault data samples in each layer of the CNN and try to analyze the reasons for the method’s high performance. The fault diagnosis accuracy of the DCG–CNN is shown to be higher than that of other traditional methods.
Aiming at the problem of poor solution selection ratio when the AlN film and porous silicon sacrificial layer are released in the ultra-thin cantilever structure and at the problem of large surface roughness after AlN graphing, the wet corrosion process parameters were optimized, and the influence of different corrosive fluids and corrosion times on the surface roughness of AlN and the influence on the etching rate of AlN were studied, and different process parameters were selected for experiments. According to the experimental results, a suitable microstructure processing method was selected to effectively reduce the surface roughness of AlN and improve the integrity of the AlN film and the reliability and yield of the cantilever structure when the sacrificial layer is released. The microstructure fabrication of AlN films in ultra-thin cantilever structures enables the fabrication of ultra-micro-force sensors, accelerometers, acoustic sensors, and other devices.