The launcher mirrors will allow the injection of microwave power from the gyrotrons in the plasma of the Divertor Tokamak Test facility, under construction in Italy. The active cooling of the elliptical M1 (curved and not-steerable) and M2 (flat and steerable) mirrors, both subject to a significant heat load, is investigated in this article. Several cooling solutions are analyzed: a spiral cooling for M1, both in a massive and in a lightened configuration, and also a radial-azimuthal cooling for M2, both in a massive and in a lightened configuration. Figures of merit are computed for the different configurations.
The design and manufacturing of different full-size mock-ups of the resonance cavity of gyrotrons, relevant for fusion applications, were performed according to two different cooling strategies. The first one relies on mini-channels, which are very promising in the direction of increasing the heat transfer in the heavily loaded cavity, but which could face an excessively large pressure drop, while the second one adopts the solution of Raschig rings, already successfully used in European operating gyrotrons. The mock-ups, manufactured with conventional techniques, were hydraulically characterized at the Thales premises, using water at room temperature. The measured pressure drop data were used to validate the corresponding numerical computational fluid dynamics (CFD) models, developed with the commercial software STAR-CCM+ (Siemens PLM Software, Plano TX, U.S.A.) and resulting in excellent agreement with the test results. When the validated models were used to compare the two optimized cooling configurations, it resulted that, for the same water flow, the mini-channel strategy gave a pressure drop was two-fold greater than that of the Raschig rings strategy, allowing a maximum flow rate of 1 × 10−3 m3/s to meet a maximum allowable pressure drop of 0.5 MPa.
10 December 2022 in Nuclear Engineering and Technology
The performance of MW-class gyrotrons, candidate technology for the plasma external heating in magnetic-confined fusion machines, crucially depends on the heat sink capability and thermomechanical stability of the resonator cavity. Because of the high and nonlinear heat flux and consequent high temperature reached on the cavity inner surface, high thermomechanical stresses are typically observed, and large displacements jeopardize the operation. An efficient cooling, typically with subcooled water in forced flow, beside reducing the displacement and stress of the cavity, allows to select operative modes with high beam/wave interaction efficiency. An optimized solution for the cavity cooling is addressed here, which should minimize the frequency shift of the radio frequency wave by controlling the displacements on the inner wall of the cavity while respecting the yield strength limit. The optimization study is based on a biogeography-based optimization (BBO) algorithm, which targets the optimal profile of the heat transfer coefficient (HTC) to the coolant, capable to guarantee that the maximum stress in the resonator is lower than its yield strength while minimizing the inner wall displacements. The optimum analytical HTC is translated into an engineering design and its thermal-hydraulic as well as mechanical performance (hot spot temperature, pressure drop, and displacements/stresses) is compared to the current existing cooling solution, showing potential advantages.
5 May 2022 in International Journal of Heat and Fluid Flow