Bringing a diagnostic point of care test (POCT) to a healthcare market can be a painful experience as it requires the manufacturer to meet considerable technical, financial, managerial, and regulatory challenges. In this opinion article we propose a framework for developing the evidence needed to support product development, marketing, and adoption. We discuss each step in the evidence development pathway from the invention phase to the implementation of a new POCT in the healthcare system. We highlight the importance of articulating the value propositions and documenting the care pathway. We provide guidance on how to conduct care pathway analysis as little has been published on this. We summarize the clinical, economic and qualitative studies to be considered for developing evidence, and provide useful links to relevant software, on-line applications, websites, and give practical advice. We also provide advice on patient and public involvement and engagement (PPIE), and on product management. Our aim is to help device manufacturers to understand the concepts and terminology used in evaluation of in vitro diagnostics (IVDs) so that they can communicate effectively with evaluation methodologists, statisticians, and health economists. Manufacturers of medical tests and devices can use the proposed framework to plan their evidence development strategy in alignment with device development, applications for regulatory approval, and publication.
18 April 2019 in Diagnostic and Prognostic Research
Carbapenemase-producing Enterobacteriaceae (CPE), bacteria which are resistant to the carbapenem class of antibiotics, present an urgent public health risk. The objective of this study was to assess the potential costs and consequences of implementing a testing strategy involving a polymerase chain reaction (PCR)-based diagnostic test for CPE amongst high risk patients upon admission to UK hospitals, to replace the current culture-based testing strategy. A decision-analytic model was developed to estimate the expected medical care costs associated with a PCR testing strategy for CPE compared with the current culture testing strategy, and to consider the consequences, in terms of the diagnostic accuracy and associated cost implications, of each approach. The modelled population were patients admitted to hospital at high risk of colonisation with CPE, with model pathways for current practice based on those described in the Public Health England (PHE) toolkit for CPE testing. Costs were estimated from a UK National Health Service (NHS) perspective, with outcomes presented in terms of percentage of samples identified as true positive, false positive, true negative and false negative following each method of testing. Results indicated that the PCR testing strategy led to an estimated cost saving of £462 per patient for a 5-day hospital stay. For all sensitivity analyses conducted, PCR testing resulted in an expected cost saving. Potential cost savings approached £850 per patient for the sensitivity analysis assuming a 15-day hospital stay, indicating that PCR testing results in greater cost savings as length of stay increases. Fewer false positive, and more true negative, cases were identified with the PCR testing strategy in all analyses conducted. This economic analysis gives an insight into the potential cost savings that could be made by the UK NHS through the introduction of a PCR-based diagnostic testing strategy to replace current recommended culture-based methods for the detection of CPE. Savings are due primarily to a faster time to result with PCR, meaning that CPE-free patients are not isolated unnecessarily. Therefore, a PCR-based diagnostic may aid appropriate use of isolation resource.
12 September 2017 in Journal of Clinical Pathology
Aims: Understanding the molecular mechanisms of underlying disease has led to a movement away from the one-drug-fits-all paradigm towards treatment tailored to the genetic profile of the patient. The Biocartis Idylla platform is a novel fully automated, real-time PCR–basedin vitrodiagnostic system. The Idylla NRAS-BRAF mutation test has been developed for the qualitative detection of mutations inNRASandBRAFoncogenes, facilitating genetic profiling of patients with cancer. The aim of this study was to carry out a formal clinical performance evaluation.Methods: Two-hundred and forty-two formalin-fixed paraffin-embedded (FFPE) human malignant colorectal cancer (CRC) tissue samples were identified in departmental archives and tested with both the Idylla NRAS-BRAF mutation test and the Agena Bioscience MassARRAY test.Results: The overall concordance between the Idylla NRAS-BRAF mutation test and the MassARRAY comparator reference test result was 241/242 (99.59%, lower bound of one-sided 95% CI=98.1%) forNRASand 242/242 (lower bound of 95% one-sided 95% CI=98.89%) forBRAF. The Idylla NRAS-BRAF test detected oneNRASmutation that had not been reported by the MassARRAY comparator reference test. Reanalysis of this sample by droplet digital PCR confirmed that the mutation was present, but at an allelic frequency below the stated sensitivity level of the MassARRAY system.Conclusion: These results confirm that the Idylla NRAS-BRAF mutation test has high concordance with a widely usedNRAS-BRAFtest, and is therefore suitable for use as anin vitrodiagnostic device for this application.
1 August 2018 in Diagnostic and Prognostic Research
Influenza is an acute viral infection of the respiratory tract. A rapid confirmatory diagnosis of influenza is important, since it is highly transmissible and outbreaks of influenza within the hospital setting increase morbidity and mortality. The objective of this study was to evaluate the cost implications, from the perspective of the UK NHS, of using on-label nasal swabs with the Alere™ i Influenza A & B test in a near patient setting. A cost consequence model was developed. The time horizon of the model was from hospital admission on suspicion of influenza until the end of treatment (following a diagnosis of influenza or discharge from hospital). Data on the prevalence of influenza and the sensitivity and specificity of the Alere™ i Influenza A & B test came from two prospective observational diagnostic accuracy studies. Costs were obtained from published resources. Uncertainties in the model data were investigated using deterministic, one-way sensitivity analyses. Using the Alere™ i Influenza A & B point of care test with nasal swabs (on label) in NHS medical assessment units and emergency departments could save approximately £242,730 per 1000 adults presenting with influenza-like symptoms. The main cause for this was reduced times to availability of the result compared with the laboratory RT-PCR test. Other key drivers of savings were the cost of isolation, the prevalence of influenza, the specificity of the test, and the availability of isolation resources. The Alere™ i Influenza A & B point of care test would have greatest impact in hospitals that have extensive delays in the time to receive a result. Sensitivity analyses identified the model parameters which would have greatest effect on the result and confirmed that assumptions were conservative, i.e. did not change key results.
Objective: To assess the value added to the National Early Warning Score (NEWS) by mid-regional pro-adrenomedullin (MR-proADM) blood level in predicting deterioration in mild to moderately ill people.Design: Prospective observational study.Setting: The Medical Admissions Suite of the Royal Victoria Infirmary, Newcastle.Participants: 300 adults with NEWS between 2 and 5 on admission. Exclusion criteria included receiving palliative care, or admitted for social reasons or self-harming. Patients were enrolled between September and December 2015, and followed up for 30 days after discharge.Outcome measure: The primary outcome measure was the proportion of patients who, within 72 hours, had anacuity increase, defined as any combination of an increase of at least 2 in the NEWS; transfer to a higher-dependency bed or monitored area; death; or for those discharged from hospital, readmission for medical reasons.Results: NEWS and MR-proADM together predictedacuity increasemore accurately than NEWS alone, increasing the area under the curve (AUC) to 0.61 (95% CI 0.54 to 0.69) from 0.55 (95% CI 0.48 to 0.62). When the confounding effects of presence of chronic obstructive pulmonary disease or heart failure and interaction with MR-proADM were included, the prognostic accuracy further increased the AUC to 0.69 (95% CI 0.63 to 0.76).Conclusions: MR-proADM is potentially a clinically useful biomarker for deterioration in patients admitted to hospital with a mild to moderately severe acute illness, that is, with NEWS between 2 and 5. As a growing number of National Health Service hospitals are routinely recording the NEWS on their clinical information systems, further research should assess the practicality and use of developing a decision aid based on admission NEWS, MR-proADM level, and possibly other clinical data and other biomarkers that could further improve prognostic accuracy.
Summary: The Receiver Operating Characteristic (ROC) curve and the Area Under the Curve (AUC) of the ROC curve are widely used in discovery to compare the performance of diagnostic and prognostic assays. The ROC curve has the advantage that it is independent of disease prevalence. However, in this note, we remind scientists and clinicians that the performance of an assay upon translation to the clinic is critically dependent upon that very same prevalence. Without an understanding of prevalence in the test population, even robust bioassays with excellent ROC characteristics may perform poorly in the clinic. While the exact prevalence in the target population is not always known, simple plots of candidate assay performance as a function of prevalence rate give a better understanding of the likely real‐world performance and a greater understanding of the likely impact of variation in that prevalence on translation to the clinic.