Ju Wang

Dr. Ju Wang

Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
VSVinothini Selvaraju
Vinothini Selvaraju
NSNicolai Spicher
Nicolai Spicher
Ju WangJu Wang
Ju Wang
NGNagarajan Ganapathy
Nagarajan Ganapathy
Joana WarneckeJoana Warnecke
Joana Warnecke
Thomas DesernoThomas Deserno
Thomas Deserno
In recent years, noncontact measurements of vital signs using cameras received a great amount of interest. However, some questions are unanswered: (i) Which vital sign is monitored using what type of camera? (ii) What is the performance and which factors affect it? (iii) Which health issues are addressed by camera-based techniques? Following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) statement, we conduct a systematic review of continuous camera-based vital sign monitoring using Scopus, PubMed, and the Association for Computing Machinery (ACM) databases. We consider articles that were published between January 2018 and April 2021 in the English language. We include five vital signs: heart rate (HR), respiratory rate (RR), blood pressure (BP), body skin temperature (BST), and oxygen saturation (SpO2). In total, we retrieve 905 articles and screened them regarding title, abstract, and full text. One hundred and four articles remained: 60, 20, 6, 2, and 1 of the articles focus on HR, RR, BP, BST, and SpO2, respectively, and 15 on multiple vital signs. HR and RR can be measured using red, green, and blue (RGB) and near-infrared (NIR) as well as far-infrared (FIR) cameras. So far, BP and SpO2 are monitored with RGB cameras only, whereas BST is derived from FIR cameras only. Under ideal conditions, the root mean squared error is around 2.60 bpm, 2.22 cpm, 6.91 mm Hg, 4.88 mm Hg, and 0.86 °C for HR, RR, systolic BP, diastolic BP, and BST, respectively. The estimated error for SpO2 is less than 1%, but it increases with movements of the subject and the camera-subject distance. Camera-based remote monitoring mainly explores intensive care, post-anaesthesia care, and sleep monitoring, but also explores special diseases such as heart failure. The monitored targets are newborn and pediatric patients, geriatric patients, athletes (e.g., exercising, cycling), and vehicle drivers. Camera-based techniques monitor HR, RR, and BST in static conditions within acceptable ranges for certain applications. The research gaps are large and heterogeneous populations, real-time scenarios, moving subjects, and accuracy of BP and SpO2 monitoring.

28 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Ju WangJu Wang
Ju Wang
NSNicolai Spicher
Nicolai Spicher
Joana WarneckeJoana Warnecke
Joana Warnecke
Mostafa HaghiMostafa Haghi
Mostafa Haghi
JSJonas Schwartze
Jonas Schwartze
Thomas DesernoThomas Deserno
Thomas Deserno
With the advances in sensor technology, big data, and artificial intelligence, unobtrusive in-home health monitoring has been a research focus for decades. Following up our research on smart vehicles, within the framework of unobtrusive health monitoring in private spaces, this work attempts to provide a guide to current sensor technology for unobtrusive in-home monitoring by a literature review of the state of the art and to answer, in particular, the questions: (1) What types of sensors can be used for unobtrusive in-home health data acquisition? (2) Where should the sensors be placed? (3) What data can be monitored in a smart home? (4) How can the obtained data support the monitoring functions? We conducted a retrospective literature review and summarized the state-of-the-art research on leveraging sensor technology for unobtrusive in-home health monitoring. For structured analysis, we developed a four-category terminology (location, unobtrusive sensor, data, and monitoring functions). We acquired 912 unique articles from four relevant databases (ACM Digital Lib, IEEE Xplore, PubMed, and Scopus) and screened them for relevance, resulting in n=55 papers analyzed in a structured manner using the terminology. The results delivered 25 types of sensors (motion sensor, contact sensor, pressure sensor, electrical current sensor, etc.) that can be deployed within rooms, static facilities, or electric appliances in an ambient way. While behavioral data (e.g., presence (n=38), time spent on activities (n=18)) can be acquired effortlessly, physiological parameters (e.g., heart rate, respiratory rate) are measurable on a limited scale (n=5). Behavioral data contribute to functional monitoring. Emergency monitoring can be built up on behavioral and environmental data. Acquired physiological parameters allow reasonable monitoring of physiological functions to a limited extent. Environmental data and behavioral data also detect safety and security abnormalities. Social interaction monitoring relies mainly on direct monitoring of tools of communication (smartphone; computer). In summary, convincing proof of a clear effect of these monitoring functions on clinical outcome with a large sample size and long-term monitoring is still lacking.

18 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Mostafa HaghiMostafa Haghi
Mostafa Haghi
SDSaeed Danyali
Saeed Danyali
Sina AyassehSina Ayasseh
Sina Ayasseh
Ju WangJu Wang
Ju Wang
RARahmat Aazami
Rahmat Aazami
Thomas DesernoThomas Deserno
Thomas Deserno
The World Health Organization (WHO) recognizes the environmental, behavioral, physiological, and psychological domains that impact adversely human health, well-being, and quality of life (QoL) in general. The environmental domain has significant interaction with the others. With respect to proactive and personalized medicine and the Internet of medical things (IoMT), wearables are most important for continuous health monitoring. In this work, we analyze wearables in healthcare from a perspective of innovation by categorizing them according to the four domains. Furthermore, we consider the mode of wearability, costs, and prolonged monitoring. We identify features and investigate the wearable devices in the terms of sampling rate, resolution, data usage (propagation), and data transmission. We also investigate applications of wearable devices. Web of Science, Scopus, PubMed, IEEE Xplore, and ACM Library delivered wearables that we require to monitor at least one environmental parameter, e.g., a pollutant. According to the number of domains, from which the wearables record data, we identify groups: G1, environmental parameters only; G2, environmental and behavioral parameters; G3, environmental, behavioral, and physiological parameters; and G4 parameters from all domains. In total, we included 53 devices of which 35, 9, 9, and 0 belong to G1, G2, G3, and G4, respectively. Furthermore, 32, 11, 7, and 5 wearables are applied in general health and well-being monitoring, specific diagnostics, disease management, and non-medical. We further propose customized and quantified output for future wearables from both, the perspectives of users, as well as physicians. Our study shows a shift of wearable devices towards disease management and particular applications. It also indicates the significant role of wearables in proactive healthcare, having capability of creating big data and linking to external healthcare systems for real-time monitoring and care delivery at the point of perception.

25 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Ju WangJu Wang
Ju Wang
Joana WarneckeJoana Warnecke
Joana Warnecke
Mostafa HaghiMostafa Haghi
Mostafa Haghi
Thomas DesernoThomas Deserno
Thomas Deserno
Unobtrusive in-vehicle health monitoring has the potential to use the driving time to perform regular medical check-ups. This work intends to provide a guide to currently proposed sensor systems for in-vehicle monitoring and to answer, in particular, the questions: (1) Which sensors are suitable for in-vehicle data collection? (2) Where should the sensors be placed? (3) Which biosignals or vital signs can be monitored in the vehicle? (4) Which purposes can be supported with the health data? We reviewed retrospective literature systematically and summarized the up-to-date research on leveraging sensor technology for unobtrusive in-vehicle health monitoring. PubMed, IEEE Xplore, and Scopus delivered 959 articles. We firstly screened titles and abstracts for relevance. Thereafter, we assessed the entire articles. Finally, 46 papers were included and analyzed. A guide is provided to the currently proposed sensor systems. Through this guide, potential sensor information can be derived from the biomedical data needed for respective purposes. The suggested locations for the corresponding sensors are also linked. Fifteen types of sensors were found. Driver-centered locations, such as steering wheel, car seat, and windscreen, are frequently used for mounting unobtrusive sensors, through which some typical biosignals like heart rate and respiration rate are measured. To date, most research focuses on sensor technology development, and most application-driven research aims at driving safety. Health-oriented research on the medical use of sensor-derived physiological parameters is still of interest.

22 August 2014 in Informatics for Health and Social Care
Verified
Journal Article
Closed access
MMMichael Marschollek
Michael Marschollek
MBMarcus Becker
Marcus Becker
JBJürgen M. Bauer
Jürgen M. Bauer
PBPetra Bente
Petra Bente
LDLena Dasenbrock
Lena Dasenbrock
RHReinhold Haux
Reinhold Haux
Demographic change will lead to a diminishing care workforce faced with rising numbers of older persons in need of care, suggesting meaningful use of health-enabling technologies, and home monitoring in particular, to contribute to supporting both the carers and the persons in need. We present and discuss the GAL-NATARS study design along with first results regarding technical feasibility of long-term home monitoring and acceptance of different sensor modalities. Fourteen geriatric participants with mobility-impairing fractures were recruited in three geriatric clinics. Following inpatient geriatric rehabilitation, their homes were equipped with ambient sensor components for three months. Additionally, a wearable accelerometer was employed. Technical feasibility was assessed by system and component downtimes, technology acceptance by face-to-face interviews. The overall system downtime was 6%, effected by two single events, but not by software failures. Technology acceptance was rated very high by all participants at the end of the monitoring periods, and no interference with their social lives was reported. Home-monitoring technologies were well-accepted by our participants. The information content of the data still needs to be evaluated with regard to clinical outcome parameters as well as the effect on the quality of life before recommending large-scale implementations.

2 January 2019 in Applied Clinical Informatics
Verified
Journal Article
Closed access
PDF file
Ju WangJu Wang
Ju Wang
HLHongyuan Liang
Hongyuan Liang
HKHong Kang
Hong Kang
YGYang Gong
Yang Gong
Background While health information technology (health IT) is able to prevent medication errors in many ways, it may also potentially introduce new paths to errors. To understand the impact of health IT induced medication errors, this study aims to conduct a retrospective analysis of medication safety reports. Methods From the U.S. Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience database, we identified reports in which health IT is a contributing factor to medication errors. We applied two conceptual frameworks, Sittig and Singh's sociotechnical model and Coiera's information value chain, to examine the identified reports. Results We identified 152 unique reports on health IT induced medication errors as the final report set for review. The majority (65.13%) of the reports involved multiple contributing factors according to the sociotechnical model. Three dimensions, that is, clinical content, human–computer interface, and people, were involved in more reports than the others. The transition of the effects of health IT on medication practice was summarized using information value chain. Health IT related contributing factors may lead to receiving wrong information, missing information, receiving partial information and delayed information, and receiving wrong information and missing information tend to cause the commission errors in decision-making. Conclusion The two frameworks provide an opportunity to understand a comprehensive context of safety event and the impact of health IT induced errors on medication safety. The sociotechnical model helps identify the aspects causing medication safety issues. The information value chain helps uncover the effect of the health IT induced medication errors on health care process and patient outcomes.