By using the 8-node-quadrangular isoparametric element to discretize the speckle image, a 8-node-quadrangular mesh-based digital image correlation method is proposed. The model of 8-node-quadrangular mesh digital image correlation and its solving scheme based on the Newton–Raphson iteration have been constructed. The method is realized and then verified with speckle images produced by numerical simulations and real experiments. The results show that the 8-node-quadrangular mesh digital image correlation has a similar accuracy on a simple deformation measurement (translation, rotation and constant strain deformation) compared with mesh digital image correlation using the simple 4-node-quadrangular element. But for a heterogeneous deformation field measurement, the 8-node-quadrangular mesh digital image correlation has a higher accuracy because the 8-node isoparametric element used has the second-order interpolation accuracy, which is higher than that in 4-node-quadrangular mesh digital image correlation and in the conventional subset-based digital image correlation. Moreover, the 8-node-quadrangular mesh digital image correlation has the advantage for the measurement of a specimen with circular edges; the 8-node-quadrangular mesh digital image correlation can measure the displacement of all points close, even on, the curve edges because the 8-node-quadrangular isoparametric element is able to be mapped onto an element with second-order curved edges.
The systematic error for photomechanic methods caused by self-heating induced image expansion when using a digital camera was systematically studied, and a new physical model to explain the mechanism has been proposed and verified. The experimental results showed that the thermal expansion of the camera outer case and lens mount, instead of mechanical components within the camera, were the main reason for image expansion. The corresponding systematic error for both image analysis and fringe analysis based photomechanic methods were analyzed and measured, then error compensation techniques were proposed and verified.
16 February 2018 in Measurement Science and Technology
Compared to other approaches to improving digital image correlation (DIC) measurement accuracy, improving image quality is becoming increasingly effective. Image noise level, which is the main indicator of image quality, is very sensitive to the configurations of an imaging system and affects DIC measurement accuracy. However, the mechanism by which the imaging configurations affect accuracy is unclear. In this study, the influence of imaging configuration on DIC measurement accuracy was investigated using the common factor of noise. Firstly, the type and levels of noise introduced into actual images by different imaging system configurations were investigated. Next, the effect of noise on DIC measurement accuracy was determined using simulated images. Finally, the effects of imaging configuration on DIC measurement accuracy were experimentally investigated using actual measurements. The results show that both camera-related and lens-related configurations affect DIC measurement accuracy. In particular, lengthening the exposure time and reducing the f -number of the lens achieve similar improvement in DIC measurement accuracy, and a prime lens with high light transmittance is recommended for full-field optical measurements. In contrast, the imaging gain does not affect the accuracy of DIC measurements.
Moiré technique is often used to measure surface morphology and deformation fields. CCD moiré is a special kind of moiré and is produced when a digital camera is used to capture periodic grid structures, like gratings. Different from the ordinary moiré setups with two gratings, however, CCD moiré requires only one grating. But the formation mechanism is not fully understood and also, a high-quality CCD moiré pattern is hard to achieve. In this paper, the formation mechanism of a CCD moiré pattern, based on the imaging principle of a digital camera, is analyzed and a way of simulating the pattern is proposed. A universal period formula is also proposed and the validity of the simulation and formula is verified by experiments. The proposed model is shown to be an efficient guide for obtaining high-quality CCD moiré patterns.
26 February 2018 in Science China Physics, Mechanics & Astronomy