Maria Luisa Ricci

Dr. Maria Luisa Ricci

Department of Infectious Diseases, National Reference Laboratory for Legionella, Rome, Italy

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in The Lancet
Verified
Journal Article
Closed access
Maria Luisa RicciMaria Luisa Ricci
Maria Luisa Ricci
SFStefano Fontana
Stefano Fontana
FPFederica Pinci
Federica Pinci
EFEmanuela Fiumana
Emanuela Fiumana
MPMaria Federica Pedna
Maria Federica Pedna
Maria ScaturroMaria Scaturro
Maria Scaturro

18 February 2011 in Journal of Applied Microbiology
Verified
Journal Article
Open access
PDF file
JLJ.V. Lee
J.V. Lee
SLS. Lai
S. Lai
MEM. Exner
M. Exner
JLJ. Lenz
J. Lenz
VGV. Gaia
V. Gaia
SSS. Surman-Lee
S. Surman-Lee
To perform an international trial to derive alert and action levels for the use of quantitative PCR (qPCR) in the monitoring of Legionella to determine the effectiveness of control measures against legionellae. Laboratories (7) participated from six countries. Legionellae were determined by culture and qPCR methods with comparable detection limits. Systems were monitored over ≥10 weeks. For cooling towers (232 samples), there was a significant difference between the log mean difference between qPCR (GU l(-1) ) and culture (CFU l(-1) ) for Legionella pneumophila (0·71) and for Legionella spp. (2·03). In hot and cold water (506 samples), the differences were less, 0·62 for Leg. pneumophila and 1·05 for Legionella spp. Results for individual systems depended on the nature of the system and its treatment. In cooling towers, Legionella spp. GU l(-1) always exceeded CFU l(-1) , and usually Legionella spp. were detected by qPCR when absent by culture. The pattern of results by qPCR for Leg. pneumophila followed the culture trend. In hot and cold water, culture and qPCR gave similar results, particularly for Leg. pneumophila. There were some marked exceptions with temperatures ≥50°C, or in the presence of supplementary biocides. Action and alert levels for qPCR were derived that gave results comparable to the application of the European Guidelines based on culture. Algorithms are proposed for the use of qPCR for routine monitoring. Action and alert levels for qPCR can be adjusted to ensure public health is protected with the benefit that remedial actions can be validated earlier with only a small increase in the frequency of action being required. This study confirms it is possible to derive guidelines on the use of qPCR for monitoring the control of legionellae with consequent improvement to response and public health protection.

1 October 2005 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
Maria ScaturroMaria Scaturro
Maria Scaturro
MLM. Losardo
M. Losardo
GPG. De Ponte
G. De Ponte
Maria Luisa RicciMaria Luisa Ricci
Maria Luisa Ricci
In the summer of 2003 a community-acquired outbreak of Legionella pneumophila occurred in Rome, Italy. Three molecular typing methods, pulse-field gel electrophoresis, amplified fragment length polymorphism analysis, and sequence-based typing (SBT), were used to establish the clonal correlation among the isolates of the epidemic cluster. By comparison of the methods, SBT was the most rapid and the easiest to perform and provided unambiguous results.

14 June 2022 in Pathogens
Verified
Journal Article
Open access
PDF file
Francesca MondelloFrancesca Mondello
Francesca Mondello
SFStefano Fontana
Stefano Fontana
Maria ScaturroMaria Scaturro
Maria Scaturro
AGAntonietta Girolamo
Antonietta Girolamo
Marisa ColoneMarisa Colone
Marisa Colone
Maria Luisa RicciMaria Luisa Ricci
Maria Luisa Ricci
Legionella pneumophila (Lp), responsible for a severe pneumonia called Legionnaires’ disease, represents an important health burden in Europe. Prevention and control of Lp contamination in warm water systems is still a great challenge often due to the failure in disinfection procedures. The aim of this study was to evaluate the in vitro activity of Terpinen-4-ol (T-4-ol) as potential agent for Lp control, in comparison with the essential oil of Melaleuca alternifolia (tea tree) (TTO. Minimum Inhibitory Concentration (MIC) and Minimum Bactericidal Concentration (MBC) of T-4-ol were determined by broth micro-dilution and a micro-atmosphere diffusion method to investigate the anti-Lp effects of T-4-ol and TTO vapors. Scanning Electron Microscopy (SEM) was adopted to highlight the morphological changes and Lp damage following T-4-ol and TTO treatments. The greatest antimicrobial activity against Lp was shown by T-4-ol with a MIC range of 0.06–0.125% v/v and MBC range of 0.25–0.5% v/v. The TTO and T-4-ol MIC and MBC decreased with increasing temperature (36 °C to 45 ± 1 °C), and temperature also significantly influenced the efficacy of TTO and T-4-ol vapors. The time-killing assay showed an exponential trend of T-4-ol bactericidal activity at 0.5% v/v against Lp. SEM observations revealed a concentration- and temperature- dependent effect of T-4-ol and TTO on cell surface morphology with alterations. These findings suggest that T-4-ol is active against Lp and further studies may address the potential effectiveness of T-4-ol for control of water systems.

21 May 2020 in Eurosurveillance
Verified
Journal Article
Open access
MFMarino Faccini
Marino Faccini
ARAntonio Giampiero Russo
Antonio Giampiero Russo
MBMaira Bonini
Maira Bonini
STSara Tunesi
Sara Tunesi
RMRossella Murtas
Rossella Murtas
Maria Luisa RicciMaria Luisa Ricci
Maria Luisa Ricci
In July 2018, a large outbreak of Legionnaires' disease (LD) caused by Legionella pneumophila serogroup 1 (Lp1) occurred in Bresso, Italy. Fifty-two cases were diagnosed, including five deaths. We performed an epidemiological investigation and prepared a map of the places cases visited during the incubation period. All sites identified as potential sources were investigated and sampled. Association between heavy rain-fall and LD cases was evaluated in a case-crossover study. We also performed a case-control study and an aerosol dispersion investigation model. Lp1 was isolated from 22 of 598 analysed water samples; four clinical isolates were typed using monoclonal antibodies and sequence-based typing. Four Lp1 human strains were ST23, of which two were Philadelphia and two were France-Allentown subgroup. Lim ST23 France-Allentown was isolated only from a public fountain. In the case-crossover study, extreme precipitation 5-6 days before symptom onset was associated with increased LD risk. The aerosol dispersion model showed that the fountain matched the case distribution best. The case-control study demonstrated a significant eightfold increase in risk for cases residing near the public fountain. The three studies and the matching of clinical and environmental Lp1 strains identified the fountain as the source responsible for the epidemic.

1 May 2009 in Journal of Microbiological Methods
Verified
Journal Article
Closed access
Francesca MondelloFrancesca Mondello
Francesca Mondello
AGAntonietta Girolamo
Antonietta Girolamo
Maria ScaturroMaria Scaturro
Maria Scaturro
Maria Luisa RicciMaria Luisa Ricci
Maria Luisa Ricci