Background. Rapid and reliable tests are essential for the diagnostic laboratory confirmation of urinary tract infections (UTIs). Until now, UTI has been confirmed by the microbiology culture of urine, requiring at least 48-hour turnaround time (TAT), with a standardized microscopic method being widely favored. Automated urine flow cytometry, however, has recently been used to improve the rapid TAT by analyzing the urine sediment. This study therefore aimed to compare the diagnostic value of the Shih-Yung conventional microscopic and urine flow cytometry methods in the detection of leukocyte and bacterial parameters of patients with UTIs in an outpatient clinic. Methods. A cross-sectional study was conducted on a total of 100 patients. Seventy urine samples were positive for leukocytes and nitrite chemistry, and 30 were negative for both. The measurements of urine leukocytes and bacteria were compared between Sysmex UF-5000 urine flow cytometry and the Shih-Yung method. The diagnostic value was obtained from ROC analysis of urine flow cytometry and the culture. Results. A leukocyte cutoff value of 87.2/μL had a sensitivity and specificity of 98.33% and 95%, respectively, and 98.33% sensitivity and 75% specificity at a bacterial cutoff of 582.22/μL. Interestingly, our study identified strong and consistent agreement of leukocyte and bacterial parameters between urine flow cytometry and Shih-Yung (k = 0.959, and k = 0.939, , respectively). Furthermore, through analyzing the dominance angle of the scattergram, a strong agreement was obtained with the culture result (k = 0.880, ). Conclusions. The Shih-Yung method showed consistent agreement with urine flow cytometry for the detection of leukocytes and bacteria. The use of certain cutoffs for bacterial and leukocyte parameters in urine flow cytometry demonstrated very good performance in detecting acquired symptomatic UTIs.
Introduction: Dysmorphic RBC (DysRBC) as a marker of glomerular abnormalities is expected to have added value in screening for glomerular abnormalities along with other examinations, including renal tubular epithelial cells (RTECs) and pathological casts (PathCasts) that indicate tubular abnormalities in lupus nephritis (LN). Therefore, this study intended to assess the diagnostic performance of urinary cell and cast characteristics, including DysRBC, RTECs, and PathCast, as measured by the urine flow cytometry in lupus nephritic children. Methods: Urine samples from 317 patients (50.47% female and 49.53% male) were collected. The diagnostic value was evaluated using receiver operating characteristic (ROC) analysis. Results: The ROC analysis demonstrated that all parameters exhibited acceptable discriminatory performance, including %DysRBC (AUC = 0.954, p < 0.001), RTEC (AUC = 0.580, p = 0.001), and PathCast (AUC = 0.664, p = 0.001). Conclusions: DysRBC, RTECs, and PathCast may have added value in the diagnosis of LN in children, notably with excellent diagnostic value in distinguishing LN in %DysRBC. This promising result warrants evaluation with a large-scale site study.
Background. Blood gas analysis (BGA) is a decision-critical test with low biological variation, and it is increasingly performed outside the central laboratory. We synthesised the evidence on pre-analytical and analytical factors that affect its accuracy. Methods. Six databases were searched from inception to July 2026 for studies of a defined pre-analytical or analytical factor affecting blood gas parameters. The effect measure was the within-specimen paired change from immediate analysis. No stratum held more than two comparable studies, so the synthesis follows SWiM and reports no pooled magnitude. Changes were compared with published analytical specifications and with exploratory pragmatic limits. Results. Fourteen studies were included, four with extractable change data. Among pre-analytical factors, 60 min of undisturbed room-temperature storage in plastic syringes lowered pH in both contributing studies (−0.020, −0.021) and raised pCO2 in both (+2.10, +1.43 mmHg), without a consistent pO2 change. Lactate rose in all three studies with extractable lactate data (+0.55 to +1.37 mmol/L). Within patients, chilling raised pO2 by +18.0 and +4.5 mmHg, a four-fold difference confounded with temperature, baseline pO2 and study. Delay combined with mechanical stress raised pO2 by +33.7 mmHg, and air bubbles, plastic syringe walls and haemolysis also biased pO2, with haemolysis further biasing pH and electrolytes. Among analytical factors, within-run imprecision met desirable specifications, whereas the only point-of-care versus central-laboratory comparison (pO2 bias −10.1 mmHg) could not separate method bias from a median 56 min delay. Three of 14 threshold classifications changed with the limit applied, and only the 4 °C pO2 artefact exceeded every limit. Conclusions. In this limited evidence base, delay and temperature affected oxygenation and metabolic analytes in opposite directions. When pO2 is required, prompt analysis at room temperature with air expelled appears preferable. When lactate, glucose or acid–base status is the priority and delay is unavoidable, chilling may limit metabolic drift. The analytical interchangeability of point-of-care and laboratory analysers cannot be judged from the available data.