André Carvalho

Dr. André Carvalho

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2010 in AIAA Journal
Verified
Journal Article
Closed access
RPRicardo M. Paiva
Ricardo M. Paiva
ACAndré Carvalho
André Carvalho
CCCurran Crawford
Curran Crawford
Afzal SulemanAfzal Suleman
Afzal Suleman

13 June 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FRFilipe M. Reis
Filipe M. Reis
Paulo AntunesPaulo Antunes
Paulo Antunes
NMNuno Manuel Mendes Maia
Nuno Manuel Mendes Maia
ACAndré Carvalho
André Carvalho
PAPaulo Andre
Paulo Andre
Structural health monitoring (SHM) is a key factor for the correct operation in large dimension structures. In this paper, we propose and demonstrate the application of a distributed optical sensor, suitable for SHM, based on the evaluation of the speckle pattern at the output of a polymer optical fibers, aiming to evaluate the damage imposed to airborne metallic and composite structures. We propose also several algorithms to analyze the speckle data and access the imposed mechanical perturbation. The maximum sampling frequency of this method is limited by the image acquisition devices, yielding to a value of 15 Hz in our case.

1 October 2016 in Theoretical and Applied Fracture Mechanics
Verified
Journal Article
Closed access
ACAndré Carvalho
André Carvalho
Diogo MontalvaoDiogo Montalvao
Diogo Montalvao
MFManuel Freitas
Manuel Freitas
LRLuis Reis
Luis Reis
MFManuel Fonte
Manuel Fonte

1 January 2016 in Procedia Structural Integrity
Verified
Journal Article
Open access
ACAndré Carvalho
André Carvalho
MFManuel Freitas
Manuel Freitas
LRLuis Reis
Luis Reis
Diogo MontalvaoDiogo Montalvao
Diogo Montalvao
MFManuel Fonte
Manuel Fonte
Endodontic rotary file instruments used to treat root canals in dentistry suffered breakthrough transformations in recent years when stainless steel was replaced by Nickel-Titanium (NiTi). NiTi alloys used in Endodontics possess superelastic properties at body temperature (37C) that bring many advantages on the overall performance of the root-canal treatment. They can follow curved root canals more easily than stainless steel instruments and have been reported to be more effective in the removal of the inflamed pulp tissue and protection of the tooth structure. However, these instruments eventually fracture under cyclic bending loading due to fatigue, without any visible signals of degradation to the practitioner. This problem brought new challenges on how new instruments should be tested, as NiTi alloys are highly non-linear and present a large hysteresis cycle in the Elastic domain. Current existing standards are only available for Stainless Steel testing. Thus, many authors have attempted to design systems that can test NiTi endodontic files under fatigue loads. However, no approach has been universally adopted by the community yet, as in most cases they are based on empirical set ups. Following a more systematic approach, this work presents the results of rotary fatigue tests for several NiTi wires from different manufacturers (Memry™ and Euroflex™). The formulation is presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure, as well numerical FEM simulation to verify the analytical model predictions

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
ACAndré Carvalho
André Carvalho
Manuel FreitasManuel Freitas
Manuel Freitas
LRLuis Reis
Luis Reis
Diogo MontalvaoDiogo Montalvao
Diogo Montalvao
MFManuel Fonte
Manuel Fonte
Endodontic rotary file instruments used to treat root canals in dentistry suffered breakthrough transformations in recent years when stainless steel was replaced by Nickel-Titanium (NiTi). NiTi alloys used in Endodontics possess superelastic properties at body temperature (37C) that bring many advantages on the overall performance of the root-canal treatment. They can follow curved root canals more easily than stainless steel instruments and have been reported to be more effective in the removal of the inflamed pulp tissue and protection of the tooth structure. However, these instruments eventually fracture under cyclic bending loading due to fatigue, without any visible signals of degradation to the practitioner. This problem brought new challenges on how new instruments should be tested, as NiTi alloys are highly non-linear and present a large hysteresis cycle in the Elastic domain. Current existing standards are only available for Stainless Steel testing. Thus, many authors have attempted to design systems that can test NiTi endodontic files under fatigue loads. However, no approach has been universally adopted by the community yet, as in most cases they are based on empirical set ups. Following a more systematic approach, this work presents the results of rotary fatigue tests for several NiTi wires from different manufacturers (MemryTM and EuroflexTM). The tests were done on a versatile fully automatic rotary bending testing machine. The formulation is also presented, where the material strength reduction can be quantified from the determination of the strain and the number of cycles until failure

27 July 2012 in Multibody System Dynamics
Verified
Journal Article
Closed access
PDF file
ACAndré Carvalho
André Carvalho
Afzal SulemanAfzal Suleman
Afzal Suleman