Andrei Vasile Nastuta

Prof. Dr. Andrei Vasile Nastuta

Grigore T. Popa University of Medicine and Pharmacy, Iaşi, Romania
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2011 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
Andrei Vasile NastutaAndrei Vasile Nastuta
Andrei Vasile Nastuta
Ionut TOPALAIonut TOPALA
Ionut TOPALA
CGConstantin Grigoras
Constantin Grigoras
Valentin PohoataValentin Pohoata
Valentin Pohoata
GPGheorghe Popa
Gheorghe Popa
New experiments using atmospheric pressure plasma have found large application in treatment of living cells or tissues, wound healing, cancerous cell apoptosis, blood coagulation on wounds, bone tissue modification, sterilization and decontamination. In this study an atmospheric pressure plasma jet generated using a cylindrical dielectric-barrier discharge was applied for treatment of burned wounds on Wistar rats' skin. The low temperature plasma jet works in helium and is driven by high voltage pulses. Oxygen and nitrogen based impurities are identified in the jet by emission spectroscopy. This paper analyses the natural epithelization of the rats' skin wounds and two methods of assisted epithelization, a classical one using polyurethane wound dressing and a new one using daily atmospheric pressure plasma treatment of wounds. Systemic and local medical data, such as haematological, biochemical and histological parameters, were monitored during entire period of study. Increased oxidative stress was observed for plasma treated wound. This result can be related to the presence in the plasma volume of active species, such as O and OH radicals. Both methods, wound dressing and plasma-assisted epithelization, provided positive medical results related to the recovery process of burned wounds. The dynamics of the skin regeneration process was modified: the epidermis re-epitelization was accelerated, while the recovery of superficial dermis was slowed down.

16 May 2012 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
TGTorsten Gerling
Torsten Gerling
Andrei Vasile NastutaAndrei Vasile Nastuta
Andrei Vasile Nastuta
RBR Bussiahn
R Bussiahn
EKE Kindel
E Kindel
KWK-D Weltmann
K-D Weltmann

10 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Andrei Vasile NastutaAndrei Vasile Nastuta
Andrei Vasile Nastuta
TGTorsten Gerling
Torsten Gerling
Application desired functionality as well as operation expenses of cold atmospheric pressure plasma (CAP) devices scale with properties like gas selection. The present contribution provides a comparative investigation for a CAP system operated in argon or helium at different operation voltages and distance to the surface. Comparison of power dissipation, electrical field strength and optical emission spectroscopy from vacuum ultraviolet over visible up to near infrared ((V)UV-VIS-NIR) spectral range is carried out. This study is extended to safety relevant investigation of patient leakage current, induced surface temperature and species density for ozone (O3) and nitrogen oxides (NOx). It is found that in identical operation conditions (applied voltage, distance to surface and gas flow rate) the dissipated plasma power is about equal (up to 10 W), but the electrical field strength differs, having peak values of 320 kV/m for Ar and up to 300 kV/m for He. However, only for Ar CAP could we measure O3 up to 2 ppm and NOx up to 7 ppm. The surface temperature and leakage values of both systems showed different slopes, with the biggest surprise being a constant leakage current over distance for argon. These findings may open a new direction in the plasma source development for Plasma Medicine.

9 May 2013 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Andrei Vasile NastutaAndrei Vasile Nastuta
Andrei Vasile Nastuta
Valentin PohoataValentin Pohoata
Valentin Pohoata
Ionut TOPALAIonut TOPALA
Ionut TOPALA
The atmospheric pressure plasma jet is studied as potential plasma source for medical applications in direct contact with living tissues. Plasma bullets are generated in the region of the high voltage electrode and propagate towards the tissue surface. The presence of a localized plasma structure on tissues, played here by a human fingertip, is experimentally revealed. It was found that this plasma structure is sustained by a current flowing through the tissue, with the magnitude dependent on the distance from the discharge tube. The characteristic time span of the plasma at the interface is up to 20 μs and the diameter up to 5 mm. These parameters were studied using the two independent techniques: ultra-fast imaging and photomultiplier measurements. Generation of supplementary reactive species at the interface, the NO molecules, was proved by optical emission spectroscopy.

3 January 2023 in Foods
Verified
Journal Article
Open access
PDF file
IBIon Burducea
Ion Burducea
CICristina Ionescu
Cristina Ionescu
PMPaul Mereuta
Paul Mereuta
SSStefan-Robert Sirbu
Stefan-Robert Sirbu
DIDecebal-Alexandru Iancu
Decebal-Alexandru Iancu
Andrei Vasile NastutaAndrei Vasile Nastuta
Andrei Vasile Nastuta
The use of cold plasma in the treatment of seeds before sowing presents a promising technique for sustainable agriculture. The objective of this study is to evaluate the effect of cold plasma treatment on the morphology of wheat seeds (Triticum aestivum L. ‘Dacic’ and ‘Otilia’), their germination, biochemical composition, and the nutritional quality of wheat grass. Wheat seeds were morphologically and elementally characterized by atomic force microscopy (AFM), scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray computer tomography (CT), and particle-induced X-ray emission (PIXE). Helium was used as a working gas for plasma generation and the analysis of the species produced showed the presence of NOγ, OH, N2 and N2+ and O. Evaluation of germination and plant growth for 10 days (wheat grass stage) highlighted a specific trend for each cultivar. The biochemical analysis of wheat grass highlighted an increase in the chlorophyll content in the plasma-treated variants, an increase in the flavonoid and polyphenol content in ‘Dacic’-treated variant, while the soluble protein content, antioxidant activity, and color were not affected. The analysis of the nutritional quality of wheat grass by the FT-NIR analytical technique highlighted an increase in the ash content in the plasma-treated wheat cultivars, while the humidity, proteins, neutral detergent fiber (NDF), acid detergent fiber (ADF), and energy values were not affected.

1 February 2011 in Applied Surface Science
Verified
Journal Article
Closed access
DCDorel Crişan
Dorel Crişan
NDNicolae Drăgan
Nicolae Drăgan
MRMălina Răileanu
Mălina Răileanu
MCMaria Crişan
Maria Crişan
AIAdelina Ianculescu
Adelina Ianculescu
DMDiana Mardare
Diana Mardare