Abdallah M. Almomani

Dr. Abdallah M. Almomani

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2017 in Polymers
Verified
Journal Article
Open access
PDF file
AAAbdallah M. Almomani
Abdallah M. Almomani
WHWangyujue Hong
Wangyujue Hong
WHWei Hong
Wei Hong
Reza MontazamiReza Montazami
Reza Montazami
Ionic polymer-metal composite (IPMC) actuators have considerable potential for a wide range of applications. Although IPMC actuators are widely studied for their electromechanical properties, most studies have been conducted at the ambient conditions. The electromechanical performance of IPMC actuators at higher temperature is still far from understood. In this study, the effect of temperature on the electromechanical behavior (the rate of deformation and curvature) and electrochemical behavior (current flow) of ionic liquid doped IPMC actuators are examined and reported. Both electromechanical and electrochemical studies were conducted in air at temperatures ranging from 25 °C to 90 °C. Electromechanically, the actuators showed lower cationic curvature with increasing temperature up to 70 °C and a slower rate of deformation with increasing temperature up to 50 °C. A faster rate of deformation was recorded at temperatures higher than 50 °C, with a maximum rate at 60 °C. The anionic response showed a lower rate of deformation and a higher anionic curvature with increasing temperatures up to 50 °C with an abrupt increase in the rate of deformation and decrease of curvature at 60 °C. In both cationic and anionic responses, actuators started to lose functionality and show unpredictable performance for temperatures greater than 60 °C, with considerable fluctuations at 70 °C. Electrochemically, the current flow across the actuators was increased gradually with increasing temperature up to 80 °C during the charging and discharging cycles. A sudden increase in current flow was recorded at 90 °C indicating a shorted circuit and actuator failure.

1 November 2014 in Organic Electronics
Verified
Journal Article
Closed access
WHWangyujue Hong
Wangyujue Hong
AAAbdallah M. Almomani
Abdallah M. Almomani
Reza MontazamiReza Montazami
Reza Montazami

13 September 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBMuath Bani-hani
Muath Bani-hani
AAAbdallah M. Almomani
Abdallah M. Almomani
KAKhaled F. Aljanaideh
Khaled F. Aljanaideh
Sallam KouritemSallam Kouritem
Sallam Kouritem
Earthquake-induced structural vibration is converted into an instant voltage signal via piezoelectric material for sensing purposes where it can be detected and read by a self-powered/self-sensing capabilities sensor located in remote and inaccessible areas. The motivating sensor is expected to wirelessly transmit vital information for monitoring purposes. A typical earthquake’s acceleration frequency components range as low from 1Hz to 17 Hz. Therefore, the motivating sensor is designed to resonate at its fundamental mode shapes to generate a readable voltage signal and power enough to meet the minimum power consumption needs of a typical acceleration sensor. The proposed sensor consists of a stack of 17 individual uniform simply supported composite-piezoelectric beams with a proof mass in the mid-span of each beam. The proof mass is utilized to enhance the voltage signal and to lower the device natural frequencies. Genetic Algorithm (GA) based optimization method is employed to optimize the 1 st natural frequency of the nth beam of the proposed sensing device to match it with one of a typical earthquake ground excitation frequencies at an increment of 1Hz. The fundamental mode is the most sensitive mode to the proof mass. Furthermore, the difference between the higher natural frequencies decreases when increasing the size of the proof mass. The analytical and the decoupled electro-mechanical equations are presented by employing the assumptions of Euler–Bernoulli’s thin beam hypothesis. The analytical results are then numerically verified by FEM by employing COMSOL multi-physics software to model and numerically simulate the proposed device/sensor.

1 January 2017 in Measurement
Verified
Journal Article
Closed access
WHWangyujue Hong
Wangyujue Hong
AAAbdallah M. Almomani
Abdallah M. Almomani
RMReza Montazami
Reza Montazami

21 June 2017 in Materials
Verified
Journal Article
Open access
PDF file
WHWangyujue Hong
Wangyujue Hong
AAAbdallah M. Almomani
Abdallah M. Almomani
YCYuanfen Chen
Yuanfen Chen
RJReihaneh Jamshidi
Reihaneh Jamshidi
Reza MontazamiReza Montazami
Reza Montazami
The most rational approach to fabricate soft robotics is the implementation of soft actuators. Conventional soft electromechanical actuators exhibit linear or circular deformation, based on their design. This study presents the use of conjugated polymers, Poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) to locally vary ion permeability of the ionic electroactive polymer actuators and manipulate ion motion through means of structural design to realize intrinsic angular deformation. Such angular deformations are closer to biomimetic systems and have potential applications in bio-robotics. Electrochemical studies reveal that the mechanism of actuation is mainly associated with the charging of electric double layer (EDL) capacitors by ion accumulation and the PEDOT:PSS layer’s expansion by ion interchange and penetration. Dependence of actuator deformation on structural design is studied experimentally and conclusions are verified by analytical and finite element method modeling. The results suggest that the ion-material interactions are considerably dominated by the design of the drop-cast PEDOT:PSS on Nafion.

1 June 2018 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
AAAbdallah M. Almomani
Abdallah M. Almomani
LGLuis Granadillo
Luis Granadillo
WHWei Hong
Wei Hong
Reza MontazamiReza Montazami
Reza Montazami
Ionomeric membranes are essential constituents of many ionic devices including fuel cells, lithium-ion polymer batteries, and ionomeric polymer transducers. Understanding the dynamics of ionic conductivity of ionomeric membranes is significant in better understanding and optimizing ionic devices. In this work, effects of temperature and Van der Waals volume of Nafion counterions on ionic conductivity of Nafion ionomeric membrane are studied. Ionic conductivity of lithium (Li+), potassium (K+), and 1-Ethyl-3-methylimidazolium (EMI+) ion-exchanged Nafion membranes at temperatures varying from 30-70 ºC was investigated and a direct correlation between ionic conductivity and both temperature and Van der Waals volume of counter ions was observed. Ionic conductivity as a function of temperature (for all three counterions) exhibited two distinct slopes below and above ~50 ºC which is an indication of changes in activation energy, and confirms previously claims of ionic decomposition of EMI-Tf ionic liquid around ~50 ºC.