Abdelmajid Saoud

Dr. Abdelmajid Saoud

mechanical Engineering, National school of engineering of gabes, Gabès, Tunisia

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2023 in Applied Thermal Engineering
Verified
Journal Article
Open access
ASAbdelmajid Saoud
Abdelmajid Saoud
JBJoan Carles Bruno
Joan Carles Bruno
YBYasmina Boukhchanaa
Yasmina Boukhchanaa
AFAli Fellah
Ali Fellah

6 June 2024 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
ASAbdelmajid Saoud
Abdelmajid Saoud
YBYasmina Boukhchana
Yasmina Boukhchana
AFAli Fellah
Ali Fellah

25 April 2024 in Thermal Science and Engineering Progress
Verified
Journal Article
Closed access
ASAbdelmajid Saoud
Abdelmajid Saoud
YBYasmina Boukhchana
Yasmina Boukhchana
JBJoan Carles Bruno
Joan Carles Bruno
AFAli Fellah
Ali Fellah

28 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAbdelmajid Saoud
Abdelmajid Saoud
Joan Carles BrunoJoan Carles Bruno
Joan Carles Bruno
This study investigates an integrated solar-driven single-effect H2O–LiBr absorption chiller powered by low-grade thermal energy. A detailed thermodynamic model, comprising a solar collector, a thermal storage tank, and an absorption cycle, was developed using the Engineering Equation Solver (EES) software V10.561. A comprehensive parametric analysis and multi-objective optimization were then conducted to enhance both the energy and exergy performance of the system. The Response Surface Methodology (RSM), based on the Box–Behnken Design, was employed to develop regression models validated through analysis of variance (ANOVA). The generator temperature (78–86 °C), evaporator temperature (2.5–6.5 °C), and absorber/condenser temperature (30–40 °C) were selected as key variables. According to the results, the single-objective analyses revealed maximum values of COP = 0.8065, cooling capacity = 20.72 kW, and exergy efficiency = 39.29%. Subsequently, the multi-objective RSM optimization produced a balanced global optimum with COP = 0.797, cooling capacity = 20.68 kW, and exergy efficiency = 36.93%, achieved under optimal operating conditions of 78 °C generator temperature, 6.5 °C evaporator temperature, and 30 °C absorber/condenser temperature. The obtained results confirm the significance of the proposed low-grade solar absorption chiller, demonstrating comparable or superior performance to recent studies (e.g., COP ≈ 0.75–0.80 and ≈35–37%). This agreement validates the RSM-based optimization approach and confirms the system’s suitability for sustainable cooling applications in low-temperature solar environments.

4 May 2024
Verified
Book Chapter
Closed access
PDF file
ASAbdelmajid Saoud
Abdelmajid Saoud
YBYasmina Boukhchana
Yasmina Boukhchana
AFAli Fellah
Ali Fellah

18 July 2024
Verified
Book Chapter
Closed access
PDF file
ASAbdelmajid Saoud
Abdelmajid Saoud
YBYasmina Boukhchana
Yasmina Boukhchana
AFAli Fellah
Ali Fellah