Abdulhameed Abdal

Dr. Abdulhameed Abdal

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
HHHongjie Hu
Hongjie Hu
YMYuxiang Ma
Yuxiang Ma
XGXiaoxiang Gao
Xiaoxiang Gao
DSDawei Song
Dawei Song
MLMohan Li
Mohan Li
Sheng XuSheng Xu
Sheng Xu

12 September 2024 in Advanced Science
Verified
Journal Article
Open access
TSTamoghna Saha
Tamoghna Saha
MKMuhammad Inam Khan
Muhammad Inam Khan
SSSamar Singh Sandhu
Samar Singh Sandhu
LYLu Yin
Lu Yin
SESara Earney
Sara Earney
Joseph WangJoseph Wang
Joseph Wang
The demand for glucose monitoring devices has witnessed continuous growth from the rising diabetic population. The traditional approach of blood glucose (BG) sensor strip testing generates only intermittent glucose readings. Interstitial fluid‐based devices measure glucose dynamically, but their sensing approaches remain either minimally invasive or prone to skin irritation. Here, a sweat glucose monitoring system is presented, which completely operates under rest with no sweat stimulation and can generate real‐time BG dynamics. Osmotically driven hydrogels, capillary action with paper microfluidics, and self‐powered enzymatic biochemical sensor are used for simultaneous sweat extraction, transport, and glucose monitoring, respectively. The osmotic forces facilitate greater flux inflow and minimize sweat rate fluctuations compared to natural perspiration‐based sampling. The epidermal platform is tested on fingertip and forearm under varying physiological conditions. Personalized calibration models are developed and validated to obtain real‐time BG information from sweat. The estimated BG concentration showed a good correlation with measured BG concentration, with all values lying in the A+B region of consensus error grid (MARD = 10.56% (fingertip) and 13.17% (forearm)). Overall, the successful execution of such osmotically driven continuous BG monitoring system from passive sweat can be a useful addition to the next‐generation continuous sweat glucose monitors.

20 December 2023 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
TRTarek Rafeedi
Tarek Rafeedi
Abdulhameed AbdalAbdulhameed Abdal
Abdulhameed Abdal
BPBeril Polat
Beril Polat
KHKatherine A. Hutcheson
Katherine A. Hutcheson
ESEileen H. Shinn
Eileen H. Shinn
DLDarren J. Lipomi
Darren J. Lipomi
Swallowing is an ensemble of voluntary and autonomic processes key to maintaining our body’s homeostatic balance. Abnormal swallowing (dysphagia) can cause dehydration, malnutrition, aspiration pneumonia, weight loss, anxiety, or even mortality—especially in older adults—by airway obstruction. To prevent or mitigate these outcomes, it is imperative to regularly assess swallowing ability in those who are at risk of developing dysphagia and those already diagnosed with it. However, current diagnostic tools such as endoscopy, manometry, and videofluoroscopy require access to clinical experts to interpret the results. These results are often sampled from a limited examination timeframe of swallowing activity in a controlled environment. Additionally, there is some risk of periprocedural complications associated with these methods. In contrast, the field of epidermal sensors is finding non-invasive and minimally obtrusive ways to examine swallowing function and dysfunction. In this review, we summarize the current state of wearable devices that are aimed at monitoring swallowing function and detecting its abnormalities. We pay particular attention to the materials and design parameters that enable their operation. We examine a compilation of both proof-of-concept studies (which focus mainly on the engineering of the device) and studies whose aims are biomedical (which may involve larger cohorts of subjects, including patients). Furthermore, we briefly discuss the methods of signal acquisition and device assessment in relevant wearable sensors. Finally, we examine the need to increase adherence and engagement of patients with such devices and discuss enhancements to the design of such epidermal sensors that may encourage greater enthusiasm for at-home and long-term monitoring.

12 June 2024 in Science Robotics
Verified
Journal Article
Closed access
RBRachel Blau
Rachel Blau
Abdulhameed AbdalAbdulhameed Abdal
Abdulhameed Abdal
NRNicholas Root
Nicholas Root
ACAlexander X. Chen
Alexander X. Chen
TRTarek Rafeedi
Tarek Rafeedi
DLDarren J. Lipomi
Darren J. Lipomi
Electrotactile stimulus is a form of sensory substitution in which an electrical signal is perceived as a mechanical sensation. The electrotactile effect could, in principle, recapitulate a range of tactile experience by selective activation of nerve endings. However, the method has been plagued by inconsistency, galvanic reactions, pain and desensitization, and unwanted stimulation of nontactile nerves. Here, we describe how a soft conductive block copolymer, a stretchable layout, and concentric electrodes, along with psychophysical thresholding, can circumvent these shortcomings. These purpose-designed materials, device layouts, and calibration techniques make it possible to generate accurate and reproducible sensations across a cohort of 10 human participants and to do so at ultralow currents (≥6 microamperes) without pain or desensitization. This material, form factor, and psychophysical approach could be useful for haptic devices and as a tool for activation of the peripheral nervous system.

16 July 2024 in Advanced Healthcare Materials
Verified
Journal Article
Open access
RBRachel Blau
Rachel Blau
SRSamantha M. Russman
Samantha M. Russman
YQYi Qie
Yi Qie
WSWade Shipley
Wade Shipley
ALAllison Lim
Allison Lim
DLDarren J. Lipomi
Darren J. Lipomi
Durable and conductive interfaces that enable chronic and high‐resolution recording of neural activity are essential for understanding and treating neurodegenerative disorders. These chronic implants require long‐term stability and small contact areas. Consequently, they are often coated with a blend of conductive polymers and are crosslinked to enhance durability despite the potentially deleterious effect of crosslinking on the mechanical and electrical properties. Here the grafting of the poly(3,4 ethylenedioxythiophene) scaffold, poly(styrenesulfonate)‐b‐poly(poly(ethylene glycol) methyl ether methacrylate block copolymer brush to gold, in a controlled and tunable manner, by surface‐initiated atom‐transfer radical polymerization (SI‐ATRP) is described. This “block‐brush” provides high volumetric capacitance (120 F cm─3), strong adhesion to the metal (4 h ultrasonication), improved surface hydrophilicity, and stability against 10 000 charge–discharge voltage sweeps on a multiarray neural electrode. In addition, the block‐brush film showed 33% improved stability against current pulsing. This approach can open numerous avenues for exploring specialized polymer brushes for bioelectronics research and application.

4 June 2024 in ACS Materials Letters
Verified
Journal Article
Closed access
SESamuel J. Edmunds
Samuel J. Edmunds
AUArmando D. Urbina
Armando D. Urbina
HFHannah E. Fishman
Hannah E. Fishman
YQYi Qie
Yi Qie
RMRafael A. Montalvo
Rafael A. Montalvo
DLDarren J. Lipomi
Darren J. Lipomi