Abdullah Al Noman

Dr. Abdullah Al Noman

Department of Electronic and Computer Engineering, University of Limerick, Limerick, Ireland
orcid
Postdoctoral Research Fellow

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2020 in Optics Express
Verified
Journal Article
Closed access
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
JDJitendra Narayan Dash
Jitendra Narayan Dash
Xin CHENGXin CHENG
Xin CHENG
CLChern Yang Leong
Chern Yang Leong
HTHwa-Yaw Tam
Hwa-Yaw Tam
Changyuan YUChangyuan YU
Changyuan YU
A simple, reliable, and quick reactive Fabry-Pérot (FP) structure-based fiber optic pH sensor is presented. The pH-sensitive hydrogel and single-mode fiber (SMF) are placed inside a fused silica capillary to form the FP cavity. The gel thickness is characterized by the spin coating method with respect to different spin speeds. The proposed sensor shows a pH sensitivity of 0.30 nm/pH along with a fast response time of 15 s to 20 s for different pH solvents in the acidic range. Also, the temperature sensitivity of the FPI sensor is found to be -0.56 nm/°C.

1 November 2018 in Optik
Verified
Journal Article
Closed access
MJM.A.M. Johari
M.A.M. Johari
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
MKMuhammad Abdul Khudus
Muhammad Abdul Khudus
MJM.H. Jali
M.H. Jali
HYH.H.M. Yusof
H.H.M. Yusof
MYM. Yasin
M. Yasin

1 December 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
AJAshadi Md Johari
Ashadi Md Johari
MKMuhammad Abdul Khudus
Muhammad Abdul Khudus
MJMohd Hafiz Bin Jali
Mohd Hafiz Bin Jali
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
SHSulaiman Wadi Harun
Sulaiman Wadi Harun

6 October 2022 in Optics Express
Verified
Journal Article
Closed access
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
JDJitendra Narayan Dash
Jitendra Narayan Dash
Xin CHENGXin CHENG
Xin CHENG
HTHwa-Yam Tam
Hwa-Yam Tam
Changyuan YUChangyuan YU
Changyuan YU
A biocompatible, reliable and quick responsive fiber-optic sensor based on Mach-Zehnder interferometer (MZI) is demonstrated for nitrate analytes tracing. The sensor was constructed by collapsing the air holes of a short length photonic crystal fiber (PCF) with the single-mode fibers (SMFs) on both ways. The proposed sensor has been coated with a graphene-PVA (polyvinyl alcohol) membrane using the thermal coating technique to make the sensor attractive to the nitrate ions in the aqueous solution. The maximum response is found to be 0.15 pm/ppm on the nitrate measurement scale of 0 ppm to 100 ppm with an average reaction time of ∼10 s. Also, a short length of FBG (fiber Bragg grating) is implanted with SMF to improve the sensing accuracy of the presented sensor.

1 May 2019 in Optik
Verified
Journal Article
Closed access
AJAshadi Md Johari
Ashadi Md Johari
MKMuhammad Abdul Khudus
Muhammad Abdul Khudus
MJMohd Hafiz Bin Jali
Mohd Hafiz Bin Jali
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
S. W. HarunS. W. Harun
S. W. Harun

1 February 2022 in Optics Express
Verified
Journal Article
Closed access
Abdullah Al NomanAbdullah Al Noman
Abdullah Al Noman
JDJitendra Narayan Dash
Jitendra Narayan Dash
Xin CHENGXin CHENG
Xin CHENG
HTHwa-Yaw Tam
Hwa-Yaw Tam
Changyuan YUChangyuan YU
Changyuan YU
A compact, reliable, and fast responsive PCF (photonic crystal fiber) based modal interferometric sensor for lead ion detection is proposed and experimentally demonstrated. The sensor has been fabricated by splicing a small section of PCF with SMF (single mode fiber) followed by collapsing the air holes of PCF at its tip. The interferometer is dip coated with chitosan-PVA (polyvinyl alcohol) and glutathione functionalized gold nanoparticles. Three probes have been fabricated, and the maximum sensitivity has been found to be 0.031 nm/ppb for lead ions whereas the detection range has been considered from 0 ppb to 50 ppb. The probe has been found to have a faster response time of ∼ 10 s. Furthermore, the sensor has been found to be less responsive towards other heavy metal ions, thereby demonstrating its selectivity towards lead ions. Besides, a section of FBG (fiber Bragg grating) has been embedded into the interferometer and the temperature response of FBG peak along with interference spectra has been investigated for better accuracy.