Abeer Tashkandi

Dr. Abeer Tashkandi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2019 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
HEHassan El-Shamy
Hassan El-Shamy
HSHelal Sonbul
Helal Sonbul
NANajlaa Alturkestani
Najlaa Alturkestani
Abeer TashkandiAbeer Tashkandi
Abeer Tashkandi
Bas LoomansBas Loomans
Bas Loomans
WEWafa El-Badrawy
Wafa El-Badrawy
This study investigated the effect of bulk-fill composites on proximal contact tightness (PCT) of composite restorations using different matrix systems. 150/standardized-MO-ivorine cavity preparations were divided into 5 groups; Smart Dentin Replacement (SDR), SonicFill (SF), Tetric EvoCeram Bulk-Fill (TEB), G-ænial Universal Flo (GF) and Tetric EvoCeram (TE). Each group was subdivided into 3 sub-groups (n=10); Dixieland band in Tofflemire retainer, FenderMate and Palodent plus matrix systems. PCT was measured 24 h post-curing using Tooth Pressure Meter. PCT means were calculated and statistically-analyzed using ANOVA and Tukey’s post-hoc test (p<0.05). Means and SD of PCT for Tofflemire subgroup were: 1.75(0.13), 3.21(0.1), 3.06(0.19), 2.49(0.21) and 3.18(0.1) for (SDR), (SF), (TEB), (GF) and (TE), respectively. Using FenderMate, values were: 1.87(0.08), 3.35(0.12), 3.17(0.16), 2.64(0.1) and 3.26(0.11) for (SDR), (SF), (TEB), (GF) and (TE), respectively, while with Palodentplus; 3.16(0.17), 4.23(0.11), 4.1(0.1), 3.46(0.17) and 3.98(0.1) for (SDR), (SF), (TEB), (GF) and (TE), respectively. ANOVA revealed significant differences (p<0.05) between all samples except between (SF), (TEB) and (TE) and also significant difference between Palodentplus and two subgroups. Effect of bulk-fill composites on PCT is material dependent. Separation ring is recommended for proper PCT.

1 October 2024 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
MSMeyassara Samman
Meyassara Samman
Abeer TashkandiAbeer Tashkandi
Abeer Tashkandi
MAMaha Alsharif
Maha Alsharif
HAHeba Ashi
Heba Ashi
LBLina Bahanan
Lina Bahanan
Purpose: The aim of this pilot study was to assess the knowledge and perceptions surrounding the use of fake snap-on veneers, as well as to evaluate the experiences of individuals who have used them. Materials and Methods: This study was conducted between October 2021 and January 2022. A questionnaire was distributed through social media platforms to individuals aged > 18 years in Saudi Arabia, which assessed their personal and sociodemographic information and perceptions and experiences with fake snap-on veneers. The statistical analyses included descriptive statistics, bivariate analyses, and multiple logistic regressions. Results: The study included 466 participants, with the majority being young adults, with an almost equal sex distribution. The study highlighted a general reluctance to use these veneers because of concerns about dental damage and esthetics. Women and younger individuals showed higher awareness, and regional variations indicated potential cultural influences on the perception of these dental devices. Most users experienced discomfort and did not recommend the fake snap-on veneers. Conclusion: This study sheds light on a cautious approach toward fake snap-on veneers, despite their esthetic appeal. This underscores the need for strict regulations, public awareness campaigns, and ethical dental practices to ensure informed decision-making and safeguard dental health. The concept of an ideal smile has led to various cosmetic dental procedures. Snap-on veneers offer a pain-free and affordable solution, but fake versions raise concerns about discomfort, unrealistic results, and oral health issues. User complaints emphasize the need for strict regulations and public awareness campaigns to ensure informed decisions.

29 April 2025 in Polymers
Verified
Journal Article
Open access
PDF file
HYHanin E Yeslam
Hanin E Yeslam
HAHazzaa Hassan Alqahtani
Hazzaa Hassan Alqahtani
Aws FilembanAws Filemban
Aws Filemban
SJSultan Osama Jiffri
Sultan Osama Jiffri
Abeer TashkandiAbeer Tashkandi
Abeer Tashkandi
Introduction: High-performance fiber-reinforced technopolymers for computer-aided design/computer-aided manufacturing (CAD/CAM) of dental restorations offer superior durability and strength. However, exposure to acidic solutions may adversely affect these mechanical properties. Objective: This study aimed to evaluate the flexural properties of a high-strength commercially available CAD/CAM fiber-reinforced dental material in response to water, cola, and artificial gastric acid solutions. Method: Forty bar-shaped specimens (1 × 4 × 13 mm) were fabricated from a pre-polymerized glass fiber-reinforced composite (Trilor disks, Bioloren, Saronno, Italy). Ten specimens were randomly selected for baseline testing. The remaining specimens were subdivided into three groups based on the storage media (n = 10): artificial gastric acid solution, Coca-Cola, and deionized water (37 °C, 48 h). Mean flexural strengths and moduli were statistically compared at a significance level of p < 0.05. Results: No statistically significant change in flexural strength was observed after immersion in the different media. However, there was a statistically significant decrease in the flexural modulus after storage for 48 h, regardless of pH. Conclusion: Fiber-reinforced CAD/CAM technopolymers show promising strength stability in response to varying pH conditions. However, further studies are needed to investigate the material’s long-term strength stability.

25 October 2026 in Polymers
Verified
Journal Article
Open access
PDF file
MHMaher Saeed Hajjaj
Maher Saeed Hajjaj
LQLyan Y. Qari
Lyan Y. Qari
MAMaram A Alkenani
Maram A Alkenani
ABAnhar Islem Basunbul
Anhar Islem Basunbul
DBDalea M Bukhary
Dalea M Bukhary
HYHanin E Yeslam
Hanin E Yeslam
Objectives: In this study, we aimed to evaluate the effect of post design on the push-out bond strength (PBS) of self-adhesive resin cement in simulated flared root canals. Materials and Methods: A total of 135 specimens simulating flared single root canals were fabricated using standardized 3D-printed resin (FREEPRINT® CROWN; Detax GmbH, Ettlingen, Germany) and allocated into three groups: single, double, and customized glass fiber-reinforced posts (Pillar Fiber Post, TiaDent, TX, USA). All specimens were cemented using self-adhesive resin cement (Rely XTM U200, 3M ESPE, MN, USA). The specimens were then sectioned perpendicular to the long axis into coronal, middle, and apical slices, each measuring 3 mm. After thermocycling, they were tested for their push-out bond strength. Failure modes were analyzed using stereomicroscopy. A statistical analysis was completed for PBS data using a two-way ANOVA test, and failure modes were analyzed using a Chi-square test at a significance level of α = 0.05. Results: We observed statistically significant differences in the PBS between test groups (p = 0.044*). Double-post specimens exhibited the highest PBS values at the coronal section (8.26 ± 1.54 MPa), followed by the middle section (7.77 ± 1.73 MPa). Across all root sections, the PBS of double posts (7.58 ± 2.07 MPa) significantly outperformed customized (6.76 ± 1.15 MPa) and single-post (6.73 ± 1.75 MPa) groups (p = 0.029*). The coronal third (7.44 ± 1.54 MPa) consistently showed higher PBS compared to the middle (7.15 ± 1.64 MPa) and apical (6.49 ± 1.90 MPa) thirds (p = 0.027*). Failure mode analysis revealed that customized posts predominantly failed at the post-adhesive interface, whereas double posts showed a mix of adhesive failures and single posts demonstrated more adhesive failures at the canal walls. Conclusions: The use of double fiber posts significantly enhances push-out bond strength in flared canals compared to single or customized posts. Relining techniques improved canal adaptation, but the performance here did not surpass that of double-post configurations. Clinically, the double-post approach may present a simple, practical and effective alternative to improve the bond strength of fiber-reinforced posts for flared root canal systems.

22 October 2026 in Polymers
Verified
Journal Article
Open access
PDF file
YMYasser Merdad
Yasser Merdad
RARazan Alharbi
Razan Alharbi
Abeer TashkandiAbeer Tashkandi
Abeer Tashkandi
RBRenad Bakhaider
Renad Bakhaider
ADAsaad H. Doum
Asaad H. Doum
MHMohammed A Hanbazazah
Mohammed A Hanbazazah
This in vitro study compared surface roughness (Ra) and CIEDE2000 color change (ΔE00) of two giomer flowables with surface pre-reacted glass-ionomer (S-PRG) filler, Beautifil Flow Plus F00 and Beautifil Flow Plus X F00, and two nanofill resin composites, Filtek Supreme Ultra Flowable and the packable Filtek Supreme Ultra Universal, during simulated toothbrushing. Ten discs per material were cured against glass without finishing or polishing and brushed for 10,000 linear cycles at 2.5 N. Ra and color were measured at baseline and every 2500 cycles; scanning electron microscopy illustrated the surfaces. Beautifil Flow Plus X became smoother after the first 2500 cycles (p ≤ 0.001), and no material became significantly rougher. At 10,000 cycles, Filtek Supreme Ultra Universal was rougher than the three flowables. ΔE00 differed among materials (p < 0.001) but not between intervals; Beautifil Flow Plus X changed the least (mean 0.408), less than Beautifil Flow Plus (0.886) and Filtek Supreme Ultra Universal (0.768), and no disc reached the 50:50% acceptability threshold of 1.8. Without an unbrushed control, ΔE00 reflects brushing, storage, and measurement combined. Under this protocol, Beautifil Flow Plus X became smoother and changed color the least.