Alok Dhaundiyal

Dr. Alok Dhaundiyal

Environmental Physics Department, HUN-REN Centre for Energy Research, Budapest, Hungary
orcid
Looking for a new position

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
SSSuraj B. Singh
Suraj B. Singh
Muammel M. HanonMuammel M. Hanon
Muammel M. Hanon
RRRekha Rawat
Rekha Rawat
A kinetic study of pyrolysis process of Parthenium hysterophorous is carried out by using thermogravimetric analysis (TGA) equipment. The present study investigates the thermal degradation and determination of the kinetic parameters such as activation E and the frequency factor A using model-free methods given by Flynn Wall and Ozawa (FWO), Kissinger-Akahira-Sonuse (KAS) and Kissinger, and model-fitting (Coats Redfern). The results derived from thermal decomposition process demarcate decomposition of Parthenium hysterophorous among the three main stages, such as dehydration, active and passive pyrolysis. It is shown through DTG thermograms that the increase in the heating rate caused temperature peaks at maximum weight loss rate to shift towards higher temperature regime. The results are compared with Coats Redfern (Integral method) and experimental results have shown that values of kinetic parameters obtained from model-free methods are in good agreement. Whereas the results obtained through Coats Redfern model at different heating rates are not promising, however, the diffusion models provided the good fitting with the experimental data.

1 May 2020 in Solar Energy
Verified
Journal Article
Closed access
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
DADivine Atsu
Divine Atsu

9 June 2019 in Resources
Verified
Journal Article
Open access
PDF file
DADivine Atsu
Divine Atsu
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
This paper pivots around the influence of thermal parameters on the temperature distribution of a (PV) module. The solar irradiance, ambient temperature, and heat transfer coefficient were examined for four differently manufactured solar modules. A finite element analysis of the solar system was carried out to simulate the prevailing thermal conditions. It was determined through analysis that the heat transfer coefficient had a significant effect on the boundaries of the PV modules. The temperature gradient was relatively high at the boundary, whereas the main body had the least deviation from the mean value of experimental data. The high value of irradiance is favorable for a large PV system, while the heat transfer coefficient should be low for avoiding undulation of the thermal gradient across the plate. The temperature distribution on the surface of the PV modules largely depended on the geometry and the material used for the design purpose.

1 May 2017 in Environmental and Climate Technologies
Verified
Journal Article
Open access
PDF file
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
PTPramod Tewari
Pramod Tewari
The purview of paper pivoted around the pyrolysis decomposition of forest waste (pine needle litter) by thermogravimetric analysis (TGA). Experiments were carried out in the presence of Nitrogen atmosphere. The experimental data was compared with those obtained by numerical solution of distributed activation energy model (DAEM). Asymptotic expansion is adopted to evaluate the pre-exponential factor, mean activation energy and variance. The correction factor Bi has been invoked to describe accurately the differential thermogravitmeric curves of thermal decomposition of pine needles.

1 June 2018 in Acta Technologica Agriculturae
Verified
Journal Article
Open access
PDF file
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
Muammel M. HanonMuammel M. Hanon
Muammel M. Hanon
This paper deals with pyrolysis decomposition of Cedrus deodara leaves with the help of thermogravimetric analysis (TGA). Experiments are performed in the presence of inert atmosphere of nitrogen. Experiments are conducted at three different heating rates of 5 °C∙min -1 , 10 °C∙min -1 and 15 °C∙min -1 within temperature range of 35 °C to 700 °C. Arrhenius parameters such as activation energy and frequency factor are estimated by Flynn Wall and Ozawa (FWO), Kissinger-Akahira-Sonuse (KAS) and Kissinger. The activation energy and frequency factor calculated by using Kissinger method are 67.63 kJ∙mol -1 and 15.06 . 104 min -1 respectively; whereas the averaged values of the same parameters through FWO and KAS methods are 89.59 kJ∙mol -1 and 84.748 kJ∙mol -1 , 17.27 . 108 min-1 and 62.13 . 107 min -1 respectively. Results obtained through Kissinger method represent the actual values of kinetic parameters. Conversely, FWO and KAS methods reflect the apparent values of kinetic parameters, as they are highly influenced by the overlapping of competitive reactions occur during pyrolysis.

1 March 2020 in Renewable Energy
Verified
Journal Article
Closed access
Alok DhaundiyalAlok Dhaundiyal
Alok Dhaundiyal
LTLaszlo Toth
Laszlo Toth
IBIstvan Bacskai
Istvan Bacskai
DADivine Atsu
Divine Atsu