Albert James Heber

Prof. Albert James Heber

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2003 in Journal of Environmental Quality
Verified
Journal Article
Closed access
PDF file
TLTeng‐Teeh Lim
Teng‐Teeh Lim
Albert James HeberAlbert James Heber
Albert James Heber
JNJi‐Qin Ni
Ji‐Qin Ni
ASAlan L. Sutton
Alan L. Sutton
PSPing Shao
Ping Shao

1 October 2006 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
Albert James HeberAlbert James Heber
Albert James Heber
JNJi-Qin Ni
Ji-Qin Ni
TLTeng T. Lim
Teng T. Lim
PTPei-Chun Tao
Pei-Chun Tao
ASAmy M. Schmidt
Amy M. Schmidt
YZYuanhui Zhang
Yuanhui Zhang
Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 µm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with ≥10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.

1 May 2000 in Journal of Environmental Quality
Verified
Journal Article
Closed access
PDF file
JNJi‐Qin Ni
Ji‐Qin Ni
Albert James HeberAlbert James Heber
Albert James Heber
TLTeng T. Lim
Teng T. Lim
CDClaude A. Diehl
Claude A. Diehl
RDRavi K. Duggirala
Ravi K. Duggirala
ASAlan L. Sutton
Alan L. Sutton

1 December 2006 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
Albert James HeberAlbert James Heber
Albert James Heber
TLTeng-Teeh Lim
Teng-Teeh Lim
JNJi-Qin Ni
Ji-Qin Ni
PTPei-Chun Tao
Pei-Chun Tao
ASAmy M. Schmidt
Amy M. Schmidt
GBGerald B. Baughman
Gerald B. Baughman
Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) <10 μm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, non-methane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 ± 182 μg/m3 (n = 2), 553 ± 79 μg/m3 (n = 4), and 33 ± 75 μg/m3 (n = 1), respectively. The daily mean TSP concentration (n =1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 ± 619 μg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 ± 8 μg/m3. Concentrations of PM inside the swine barns were correlated to pig activity.

16 December 2010 in Sensors
Verified
Journal Article
Open access
PDF file
YCYan Chen
Yan Chen
JNJi-Qin Ni
Ji-Qin Ni
CDClaude A. Diehl
Claude A. Diehl
Albert James HeberAlbert James Heber
Albert James Heber
BBBill W. Bogan
Bill W. Bogan
LCLi-Long Chai
Li-Long Chai
Continuously monitoring the operation of each individual fan can significantly improve the measurement quality of aerial pollutant emissions from animal buildings that have a large number of fans. To monitor the fan operation by detecting the fan vibration is a relatively new technique. A low-cost electronic vibration sensor was developed and commercialized. However, its large scale application has not yet been evaluated. This paper presents long-term performance results of this vibration sensor at two large commercial layer houses. Vibration sensors were installed on 164 fans of 130 cm diameter to continuously monitor the fan on/off status for two years. The performance of the vibration sensors was compared with fan rotational speed (FRS) sensors. The vibration sensors exhibited quick response and high sensitivity to fan operations and therefore satisfied the general requirements of air quality research. The study proved that detecting fan vibration was an effective method to monitor the on/off status of a large number of single-speed fans. The vibration sensor itself was $2 more expensive than a magnetic proximity FRS sensor but the overall cost including installation and data acquisition hardware was $77 less expensive than the FRS sensor. A total of nine vibration sensors failed during the study and the failure rate was related to the batches of product. A few sensors also exhibited unsteady sensitivity. As a new product, the quality of the sensor should be improved to make it more reliable and acceptable.

1 January 2003 in Journal of Environmental Quality
Verified
Journal Article
Closed access
PDF file
TLTeng Lim
Teng Lim
Albert James HeberAlbert James Heber
Albert James Heber
JNJi-Qin Ni
Ji-Qin Ni
ASAlan L. Sutton
Alan L. Sutton
PSPing Shao
Ping Shao