Diabetic foot ulcers (DFUs) are among the most serious complications of diabetes mellitus, often resulting in infection, amputation, and increased mortality. Early detection is essential but remains difficult due to the complex interaction of neuropathy, vascular disease, and immune dysfunction. This review examines the effectiveness of thermal imaging, including approaches supported by artificial intelligence (AI), as a non-invasive tool for identifying early signs of DFUs. A total of 49 studies published between 1991 and 2024 were analysed, focusing on adult patients and primary research only. Findings show that thermal imaging can detect abnormal skin temperature patterns and early inflammation, key indicators of DFU development. AI techniques, such as machine learning and neural networks, further enhance diagnostic accuracy by identifying subtle patterns and predicting ulcer risk. Despite promising results, several limitations were noted: lack of standardised imaging protocols, inconsistent equipment quality, and small sample sizes in many studies. To improve clinical reliability, future work should focus on developing standard procedures, integrating AI with high-resolution thermal cameras, and validating these systems in real-world hospital and home-care settings. Overall, thermal imaging, especially when combined with AI, shows strong potential as a practical, non-invasive method for early DFU detection and monitoring.
Since the identification of periapical lesions typically requires invasive testing that may adversely affect individuals suffering from concomitant disease, the diagnosis of apical periodontitis remains a challenge. This study aimed to determine the effectiveness of infrared thermal imaging for the detection of asymptomatic odontogenic inflammatory response in patients with a high risk of systemic infections. The examinations were performed using the FLIR T1020 thermal camera. The acquired images were analyzed with a ThermaCAM TM Researcher Pro 2.8 SR-3. Statistical analyses were conducted using the Statistica 10 software. The Mann–Whitney U test was used for data that were not normally distributed or did not meet the assumption of homogeneity of variance, while normally distributed data were analyzed with the t-test. The mean temperature difference between the periapical regions of the suspect and contralateral teeth was found to be greatest at 30 s of mouth opening. This is a preliminary study conducted to evaluate the potential of infrared thermal imaging as a diagnostic tool for the identification and elimination of odontogenic infection foci. Thermography seems to facilitate the quantitative assessment of inflammation by displaying temperature differences between the affected and unaffected regions.
The aim of this work was to develop an original method of thermographic measurement of tongue temperature as a prognostic method in the diagnosis of general diseases. This study examined the temperature distribution on the dorsal and apical surfaces of the tongue in patients with various general diseases and introduced a procedure for cooling the oral cavity. Patients with a high risk of systemic infections were referred to the Oral and Maxillofacial Surgery Outpatient Clinic of the Medical University of Silesia (SUM) in Katowice to identify potential foci of dental infections. They underwent an evaluation of their dentition as well as a prognostic tongue examination using the thermal camera FLIR T540 with a sensitivity of <0.03 K. The obtained results revealed statistically significant differences in the tongue average temperature parameters between the two study groups—healthy patients and patients with disorders. We obtained median temperatures for tongue dorsum (TD) of 35.8 °C and 35.2 °C for healthy patients and patients with disorders, respectively. Also, statistical differences have been obtained for tongue apex (TA) average temperatures. They were 35.5 °C and 34.0 °C for healthy and patients, respectively (p = 0.0001). Similar statistical results presented significant differences in the temperature difference (defined as DT = average temperature 10 min − average temperature 2 min after rinsing of the mouth) of the examined areas of the tongue between the healthy temperature and the unhealthy patient’s temperature. It seems that thermal imaging has potential in the prevention and diagnosis of general diseases.
Over the past 20 years, the high prevalence of diabetes has become a global public health problem. Background: The objective of this study was to develop a non-invasive screening method for diabetes which will enable the detection of the disease at an early stage. Methods: This study included 63 adult patients of both sexes: 30 patients with type 2 diabetes (t2DM) and 33 healthy volunteers. The temperature distribution on the tongue’s dorsum and apex surface was studied in patients after a mouth-cooling procedure had been introduced. The study used an FLIR T540 thermal imaging camera. An analysis of the correlation between the ∆T values of the tongue dorsum and apex and the glycated hemoglobin (HbA1c) level was performed. Results: The median of the average dorsum temperature measured 10 min after mouth rinsing was almost 0.8 [°C] lower than for healthy individuals. Also, studies showed a positive average correlation with a Pearson coefficient of r = 0.46 between the HbA1c level and the ∆T of the tongue dorsum. Conclusions: Tongue temperature measured using the IRT showed a correlation with standard biochemical parameters; it may also differentiate patients and constitute a specific screening method for patients with t2DM.
1 March 2024 in Polish Journal of Medical Physics And Engineering
Introduction: Asymptomatic inflammatory foci resulting from chronic dental infections or the presence of foreign bodies, e.g., in the sinuses, leading to serious local and systemic complications. These conditions, despite the absence of symptoms, are a source of bacterial, toxic, allergic, and neurogenic effects. Despite the developed radiological diagnostics in the form of pantomographic images and cone beam computed tomography (CBCT), thermal imaging is increasingly mentioned as an auxiliary tool in detecting and treating inflammatory foci of the craniofacial region. It is due that thermal imaging can bring indirectly metabolic information about studied tissues and thus allow the detection of early inflammatory lesions yet not invisible on X-ray diagnostics. The purpose of the study was to apply and validate a protocol for identifying asymptomatic inflammatory foci in the maxillofacial area using thermal imaging. Material and methods: Patients referred to the institute were examined for the presence of inflammatory foci. Analysis of radiographs revealed asymptomatic foci in the maxillary sinus, which were associated with the presence of a displaced foreign body. Thermographic examinations were performed using a FLIR T540 thermal imaging camera. Results: The obtained results showed a significant temperature difference between the suspected and opposite sinus. It was also confirmed that after the foreign body was removed from the sinus the temperature showed a dynamic decrease in time. Conclusions: According to the study, thermography has the potential to become an essential diagnostic tool for inflammation of odontogenic origin. It offers non-invasiveness, safety, real-time imaging, painless and completely safe.
Introduction: Odontogenic infections may influence distant structures, including the eye. Their extension into the paranasal sinuses and orbital region can contribute to inflammatory and glaucomatous conditions. Case Report: A 46-year-old man was examined for a possible odontogenic source of chronic eye disease. The patient had an 18-year history of progressive vision loss in his left eye associated with Posner–Schlossmann syndrome, chronic uveitis, and episodic elevation of intraocular pressure (IOP). Imaging studies revealed the presence of a foreign body in the alveolar recess of the left maxillary sinus, as detected on panoramic radiography, cone-beam computed tomography (CBCT), and infrared thermography (IRT). Preliminary IRT examination showed marked thermal asymmetry (ΔT = 1.1 °C) between the left and right sides of the maxilla. Worsening of ocular symptoms and increased IOP despite steroid treatment prompted surgical treatment. The foreign body, identified as a root canal filling, was removed, and the chronically inflamed sinus mucosa was excised. During a follow-up visit two weeks later, the IRT examination showed a reduction in temperature difference (ΔT = 0.2 °C) and routine postoperative healing. After two months, no thermal asymmetry was found (ΔT = 0 °C), and an ophthalmological examination showed no active inflammation. Six months after the procedure, the patient remained asymptomatic, and the IRT examination revealed only minimal residual variability within the measurement tolerance (ΔT = 0.1 °C), consistent with the resolution of the sinus inflammation. Conclusions: This case highlights the value of interdisciplinary diagnostics in identifying odontogenic contributors to chronic ocular disease. Infrared thermography proved to be a helpful non-invasive adjunct for detecting and monitoring subclinical maxillary sinus inflammation.