Aleksandra Rozwadowska

Dr. Aleksandra Rozwadowska

Department of Animal Biostructure and Physiology, Wrocław University of Environmental and Life Sciences, Wrocław, Dolnośląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2020 in Polymers
Verified
Journal Article
Open access
PDF file
DKDorota Kida
Dorota Kida
OGOlimpia Gładysz
Olimpia Gładysz
MSMałgorzata Szulc
Małgorzata Szulc
JZJacek Zborowski
Jacek Zborowski
Adam JunkaAdam Junka
Adam Junka
BKBozena Karolewicz
Bozena Karolewicz
The aim of this study was to develop and assess a polyvinyl alcohol-cellulose derivatives-based film with incorporated povidone-iodine (PVP-I) predicted for applications in the treatment of periodontitis. Films were fabricated by solvent-casting, and their physical characteristics, such as their surface and structure morphology, mechanical properties, and disintegrating time, were evaluated. For in vitro iodine release studies and evaluation, the antimicrobial activity was tested using a modified disc diffusion method against five microbial strains. For further use, we selected the film with polyvinyl alcohol-hydroxypropyl methylcellulose (PVA/HPMC_B) based on acceptable physicochemical properties. To assess the subacute toxicity of the film composition, the tissue regeneration process was tested in rats and compared to a conventional dressing commonly used in wound healing (Spongostan). Seven days after implantation, dorsal skin sections and blood samples (n = 10, in total n = 30) were examined. The wound area, epithelium, and dermis were evaluated microscopically, while the blood collected from the rats underwent biochemical analysis. The blood biochemistry results were comparable in all three groups. No significant histological differences between the Spongostan and the placebo film developed after subcutaneous implantation were observed. In contrast, the inflammation stage was reduced and the “scar” in the dermis was smaller when PVP-I and PVA/HPMC_B films were used. A smaller local inflammatory response inflicted less tissue damage, leading to the activation of subsequent regeneration phases and restoration of the area to its original state. The results obtained confirmed that PVP-I incorporated into PVA-hydroxypropyl methylcellulose film is a promising drug carrier, working faster and more effectively than the other two dressing materials evaluated. These developments provide a promising alternative in tissue regeneration and the wound healing process.

10 July 2017 in Equine Veterinary Education
Verified
Journal Article
Closed access
PDF file
MSM. Szklarz
M. Szklarz
ASA. Skalec
A. Skalec
KKK. Kirstein
K. Kirstein
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
MKM. Kasparek
M. Kasparek
MWM. Waselau
M. Waselau

24 April 2018 in RSC Advances
Verified
Journal Article
Open access
PDF file
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
Patrycja Szymczyk-ZiółkowskaPatrycja Szymczyk-Ziółkowska
Patrycja Szymczyk-Ziółkowska
MDMaciej Dobrzynski
Maciej Dobrzynski
OPOlga Parulska
Olga Parulska
MSMaria Szymonowicz
Maria Szymonowicz
Rafal Jakub WigluszRafal Jakub Wiglusz
Rafal Jakub Wiglusz
In response to the need for implant materials characterized by high biocompatibility a new type of nanostructured Ti6Al7Nb implants for osseous tissue regeneration have been fabricated. The nanostructured cylindrical implants were manufactured in accordance with 3D CAD data using the Selective Laser Melting (SLM) method. Implants were subjected to chemical polishing using a mixture of nitric acid and fluoride (test group) as well as cleaned in distilled water and isopropyl alcohol (control group). The structural and morphological properties of the obtained samples were determined by using XRD (X-ray powder diffraction), TEM (transmission electron microscopy) and SEM (scanning electron microscopy) techniques. The particle size was verified and calculated by Rietveld method to be in the range of 25–90 nm. In the present study, experimental in vivo tests concerning implants fabricated from a nanostructured Ti6Al7Nb alloy, which may substitute bone tissue, were discussed in detail. The control group and test group were used in the study. The animal model was New Zealand rabbit. The implants were implanted into skull fornix and observed after 1, 2 and 3 months. The results of macroscopic and microscopic analysis proved better osseointegration of chemically modified implants.

26 July 2019 in Anatomia, Histologia, Embryologia
Verified
Journal Article
Closed access
PDF file
ASAleksandra Skalec
Aleksandra Skalec
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
ACAlbert Czerski
Albert Czerski

15 March 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
KKKarol Kirstein
Karol Kirstein
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
PKPiotr Kosior
Piotr Kosior
ADAleksander Chrószcz, DVM
Aleksander Chrószcz, DVM
KDKrzysztof Dudek
Krzysztof Dudek
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
The excessive temperature fluctuations during dental implant site preparation may affect the process of bone-implant osseointegration. In the presented studies, we aimed to assess the quality of cooling during the use of 3 different dental implant systems (BEGO®, NEO BIOTECH®, and BIOMET 3i®). The swine rib was chosen as a study model. The preparation of dental implant site was performed with the use of 3 different speeds of rotation (800, 1,200, and 1,500 rpm) and three types of cooling: with saline solution at room temperature, with saline solution cooled down to 3°C, and without cooling. A statistically significant difference in temperature fluctuations was observed between BEGO and NEO BIOTECH dental systems when cooling with saline solution at 3°C was used (22.3°C versus 21.8°C). In case of all three evaluated dental implant systems, the highest temperature fluctuations occurred when pilot drills were used for implant site preparation. The critical temperature, defined in the available literature, was exceeded only in case of pilot drills (of all 3 systems) used at rotation speed of 1,500 rpm without cooling.

1 January 2016 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Maciej JaneczekMaciej Janeczek
Maciej Janeczek
PKPiotr Kosior
Piotr Kosior
DPDagmara Piesiak-Pańczyszyn
Dagmara Piesiak-Pańczyszyn
KDKrzysztof Dudek
Krzysztof Dudek
ADAleksander Chrószcz, DVM
Aleksander Chrószcz, DVM
Maciej DobrzyńskiMaciej Dobrzyński
Maciej Dobrzyński
Measurements of the root canal during endodontic treatment have a significant influence on the course of the therapeutic process as well as on its final result in both human and veterinary medicine. The apical constriction should be the termination point for the preparation and filling of the root canal. This research was conducted with the use of a Septodont kit consisting of a small chamber filled with the examined solution in which a healthy second incisor was placed. The step back method was applied for the root canal preparation and master apical file of 30 was used. The working length was 22 mm. The examination was conducted with the use of steel as well as nickel titanium hand instruments. Different irrigation solutions and two types of apex locators were used. Measurements of the working length of the root canal showed dependence on the size of the instrument. Examinations carried out in various environments showed that analogical measurements were obtained only for sodium hypochlorite solutions. In other environments the measured sections were shortened. Comparative examinations with the use of steel instruments demonstrated insignificant measurement differences. Compared to these results, the measurements in nickel titanium group were characterized by more considerable deviations.