Optical chemical sensors can yield distinctively different responses that are dependent on the method applied for readout and evaluation. We therefore present a comprehensive study on the pH determined non-continuously with optical sensors in real milk samples by either photometry or colorimetry (via the RGB-readout of digital images) compared to the pH values obtained electrochemically by potentiometry. Additionally, the photometric determination of pH was conducted with single-wavelength and a dual wavelength ratiometric evaluation of the absorbance. It was found that both the precision and accuracy of the pH determined by photometry benefit from lower concentrations of bromocresol purple, which served as the pH indicator inside the sensor membrane. A further improvement is obtained by the ratiometric evaluation of the photometric sensor response. The pH values obtained from the colorimetric evaluation, however, gain in precision and accuracy if a higher concentration of the indicator is immobilized inside the sensor membrane. This has a major impact on the future fabrication of optical pH sensor membranes because they can be better tuned to match to the most precise and accurate range of the planned detection method.
Procedures for the photothermal lens determination of metals and organic compounds, on the basis of solid-phase mesoporous optical-sensing materials (polymethacrylate [PMA]) matrices with immobilized reagents, were developed. These procedures combine (i) selective and efficient preconcentration of trace substances to be analyzed in specially designed and synthesized transparent mesoporous PMA plates; (ii) sensitive determination with the reliable and traceable photometric reactions previously developed for classical spectrophotometry; and (iii) the sensitivity enhancement of photothermal lens detection in polymers, which provides at least a ten-fold increase in sensitivity compared with solutions due to polymer thermo-optical properties (solid phase–enhanced thermal lensing). It is shown that the overall sensitivity of photothermal lens measurements in PMA matrices is two orders higher than photometric absorbance measurements for the same excitation source power, which is in good agreement with the expected theoretical sensitivity. Changes in the preparation of transparent PMA plates and analytical procedures for photothermal measurements compared with spectrophotometry are discussed. PMA matrices modified with various analytical reagents were applied to trace determination of Hg(II), Fe(II), Ag(I), Cu(II), and ascorbic acid, with subnanomolar to nanomolar limits of detection.
The sensitivity of the earlier proposed procedures for the determination of iron(II, III) with 1,10-phenanthroline, silver(I) with dithizone, mercury with copper(II) dithizonate, copper(II) with lead...
The effect of the immobilization of 2,6-dichlorophenolindophenol ( DCIP) on a polymethacrylate matrix on its redox and acid-base properties was studied. The ionization constant and formal redox...