Alexander Kyrychenko

Prof. Alexander Kyrychenko

V. N. Karazin Kharkiv National University

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2015 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
AKAlexander Kyrychenko
Alexander Kyrychenko
OKOleksandr M. Korsun
Oleksandr M. Korsun
IGIurii I. Gubin
Iurii I. Gubin
Sergiy M. KovalenkoSergiy M. Kovalenko
Sergiy M. Kovalenko
OKOleg N. Kalugin
Oleg N. Kalugin

7 February 2017 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
AKAlexander Kyrychenko
Alexander Kyrychenko
DPDmitry A. Pasko
Dmitry A. Pasko
OKOleg N. Kalugin
Oleg N. Kalugin
In the present work, an atomistic model for the classical MD simulation of silver nanoparticles grafted with single-chain PVA of various lengths from 220 up to 1540 repeating units was developed.

8 December 2005 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
KPKarin Pettersson
Karin Pettersson
AKAlexander Kyrychenko
Alexander Kyrychenko
ERElin Rönnow
Elin Rönnow
TLThomas Ljungdahl
Thomas Ljungdahl
JMJerker Mårtensson
Jerker Mårtensson
BABo Albinsson
Bo Albinsson

1 February 2018 in Carbohydrate Polymers
Verified
Journal Article
Closed access
WPWilliam M. Payne
William M. Payne
DSDenis Svechkarev
Denis Svechkarev
AKAlexander Kyrychenko
Alexander Kyrychenko
AMAaron Mohs
Aaron Mohs


1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JMJoseph M. Muretta
Joseph M. Muretta
AKAlexander Kyrychenko
Alexander Kyrychenko
ALAlexey S. Ladokhin
Alexey S. Ladokhin
DKDavid J. Kast
David J. Kast
GGGregory D. Gillispie
Gregory D. Gillispie
DTDavid Thomas
David Thomas
We describe a high-performance time-resolved fluorescence (HPTRF) spectrometer that dramatically increases the rate at which precise and accurate subnanosecond-resolved fluorescence emission waveforms can be acquired in response to pulsed excitation. The key features of this instrument are an intense (1 μJ/pulse) , high-repetition rate (10 kHz), and short (1 ns full width at half maximum) laser excitation source and a transient digitizer (0.125 ns per time point) that records a complete and accurate fluorescence decay curve for every laser pulse. For a typical fluorescent sample containing a few nanomoles of dye, a waveform with a signal/noise of about 100 can be acquired in response to a single laser pulse every 0.1 ms, at least 105 times faster than the conventional method of time-correlated single photon counting, with equal accuracy and precision in lifetime determination for lifetimes as short as 100 ps. Using standard single-lifetime samples, the detected signals are extremely reproducible, with waveform precision and linearity to within 1% error for single-pulse experiments. Waveforms acquired in 0.1 s (1000 pulses) with the HPTRF instrument were of sufficient precision to analyze two samples having different lifetimes, resolving minor components with high accuracy with respect to both lifetime and mole fraction. The instrument makes possible a new class of high-throughput time-resolved fluorescence experiments that should be especially powerful for biological applications, including transient kinetics, multidimensional fluorescence, and microplate formats.