View All Publications
13 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
SMSanam Daneshpour Moghadam
Sanam Daneshpour Moghadam
BMBogdan Mihai MARIS
Bogdan Mihai MARIS
Ali MokhtariAli Mokhtari
Ali Mokhtari
CDClaudia Daffara
Claudia Daffara
PFPaolo Fiorini
Paolo Fiorini
Optical Coherence Tomography (OCT) is a relatively new medical imaging device that provides high-resolution and real-time visualization of biological tissues. Initially designed for ophthalmology, OCT is now being applied in other types of pathologies, like cancer diagnosis. This review highlights its impact on disease diagnosis, biopsy guidance, and treatment monitoring. Despite its advantages, OCT has limitations, particularly in tissue penetration and differentiating between malignant and benign lesions. To overcome these challenges, the integration of nanoparticles has emerged as a transformative approach, which significantly enhances contrast and tumor vascularization at the molecular level. Gold and superparamagnetic iron oxide nanoparticles, for instance, have demonstrated great potential in increasing OCT’s diagnostic accuracy through enhanced optical scattering and targeted biomarker detection. Beyond these innovations, integrating OCT with multimodal imaging methods, including magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasound, offers a more comprehensive approach to disease assessment, particularly in oncology. Additionally, advances in artificial intelligence (AI) and biosensors have further expanded OCT’s capabilities, enabling real-time tumor characterization and optimizing surgical precision. However, despite these advancements, clinical adoption still faces several hurdles. Issues related to nanoparticle biocompatibility, regulatory approvals, and standardization need to be addressed. Moving forward, research should focus on refining nanoparticle technology, improving AI-driven image analysis, and ensuring broader accessibility to OCT-guided diagnostics. By tackling these challenges, OCT could become an essential tool in precision medicine, facilitating early disease detection, real-time monitoring, and personalized treatment for improved patient outcomes.

14 January 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ali MokhtariAli Mokhtari
Ali Mokhtari
BMBogdan Mihai MARIS
Bogdan Mihai MARIS
PFPaolo Fiorini
Paolo Fiorini
This paper reviews the main research on Optical Coherence Tomography (OCT), focusing on the progress and advancements made by researchers over the past three decades in its methods and medical imaging applications. By analyzing existing studies and developments, this review aims to provide a foundation for future research in the field.

1 January 2022 in International Journal of Engineering
Verified
Journal Article
Closed access
PDF file
Ali MokhtariAli Mokhtari
Ali Mokhtari
PKPeyman Kabiri
Peyman Kabiri
The aim of the reported work is to help design of decenary Multi-Valued Logic (MVL) circuits. This paper reports a work, in which, analog voltage-based circuitry is used to design MVL circuits. In this paper, some analog circuits are reported as elements that can be used in Multi-Valued Logic (MVL) circuitry. This article reported a MOSFET-Based Differential Amplifier (MBDA) as a key element in designing decenary MVL arithmetic unit. Operating voltage range and linearity of the gain are two important characteristics of this element. The operating voltage range for the MBDA is 0V to 5.5V as a output voltage.The achieved linear gain is within the range of 0.1V to 5.3V. Analog inverter and correction buffer circuits are reported based on MBDA. Analog inverter will be used in computational and logical decenary MVL circuits. The correction buffer is designed as an element to eliminate noises and signal drift at the output of the MVL gates and during data transfer.

15 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SMSanam Daneshpour Moghadam
Sanam Daneshpour Moghadam
BMBogdan Mihai MARIS
Bogdan Mihai MARIS
Ali MokhtariAli Mokhtari
Ali Mokhtari
CDClaudia Daffara
Claudia Daffara
PFPaolo Fiorini
Paolo Fiorini
Optical Coherence Tomography (OCT) is a relatively new medical imaging device that provides high-resolution and real-time visualization of biological tissues. Initially designed for ophthalmology, OCT is starting to be applied in other types of pathologies, like cancer diagnosis. This review highlights its impact on disease diagnosis, biopsy guidance, and treatment monitoring. Despite its advantages, OCT has limitations, particularly in tissue penetration and differentiating between malignant and benign lesions. To overcome these challenges, the integration of nanoparticles has emerged as a transformative approach, which significantly enhances contrast and tumor vascularization at the molecular level. Gold and superparamagnetic iron oxide nanoparticles, for instance, have demonstrated great potential in increasing OCT’s diagnostic accuracy through enhanced optical scattering and targeted biomarker detection. Beyond these innovations, integrating OCT with multimodal imaging methods, including magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasound, offers a more comprehensive approach to disease assessment, particularly in oncology. Additionally, advances in Artificial Intelligence (AI) and biosensors have further expanded OCT’s capabilities, enabling real-time tumor characterization and optimizing surgical precision. However, despite these advancements, clinical adoption still faces several hurdles. Issues related to nanoparticle biocompatibility, regulatory approvals, and standardization need to be addressed. Moving forward, research should focus on refining nanoparticle technology, improving AI-driven image analysis, and ensuring broader accessibility to OCT-guided diagnostics. By tackling these challenges, OCT could become an essential tool in precision medicine, facilitating early disease detection, real-time monitoring, and personalized treatment for improved patient outcomes.

4 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Ali MokhtariAli Mokhtari
Ali Mokhtari
BMBogdan Mihai MARIS
Bogdan Mihai MARIS
PFPaolo Fiorini
Paolo Fiorini
This paper reviews the main research on Optical Coherence Tomography (OCT), focusing on the progress and advancements made by researchers over the past three decades in its methods and medical imaging applications. By analyzing existing studies and developments, this review aims to provide a foundation for future research in the field.