Objectives: The objectives of the current study were to validate the LittlEARS® Early Speech Production Questionnaire (LEESPQ) in Romanian and to evaluate the psychometric properties of the Romanian version of the questionnaire for Romanian children with normal hearing. The LEESPQ was created and tested for the assessment of preverbal and early verbal skills (0–18 months) in children with normal hearing. Methods: The English version of the LittlEARS® Early Speech Production Questionnaire (LEESPQ) was adapted into Romanian language using a translation/back-translation procedure and validation of the content before applying the questionnaire. The Romanian version was applied to the parents of 232 children with normal hearing, aged between 0 and 18 months. The questionnaire was statistically analyzed to assess its reliability, internal consistency, predictive accuracy, and the influence of gender on children’s scores. Results: Statistical analyses confirmed the LEESPQ’s reliability (α = 0.876) and high predictive accuracy (λ = 0.951). Age correlated strongly with total scores (ρ = 0.67; p < 0.001), supporting the age-dependent progression of speech production milestones. Gender did not significantly affect the scores. Normative curves and minimum expected scores were established for each age group. Conclusions: This study confirmed that the Romanian version of the LEESPQ is a reliable, valid, language-independent instrument, useful in the assessment of language development in children with normal hearing, aged up to 18 months.
Objective: The aim of the study was to evaluate the validity, clinical applicability, and developmental sensitivity of the Romanian LEESPQ in children with cochlear implants (CIs), by analyzing its association with age at implantation, duration of auditory experience, and implantation laterality, and by comparing the developmental trajectory with that of normal-hearing (NH) children. Methods: The study assesses the validity, reliability, and clinical sensitivity of the LEESPQ in pediatric cochlear implant users. Furthermore, it investigates the associations between total questionnaire scores and key clinical variables, including implantation laterality (unilateral versus bilateral), age at device activation, and duration of implant use. Forty-seven children with CIs (26 boys, 21 girls) were included, with implantation ages ranging from 9 months to 5 years. Of these, 21 received unilateral implants and 26 bilateral implants. Responses were analyzed both in relation to clinical variables and in comparison with available normative data from NH children, in order to delineate potential differences in linguistic developmental trajectories. Results: Findings suggest that the LEESPQ is a reliable and clinically valuable instrument for monitoring post-implant linguistic progress. It provides relevant insights into early auditory access, the linguistic environment within the family, and the development of early verbal production. Scores were significantly influenced by age at implantation and duration of auditory experience, confirming the role of early stimulation and neural plasticity in shaping speech development after cochlear implantation. Conclusions: The LEESPQ demonstrates strong clinical utility as a sensitive tool for monitoring early preverbal and verbal development in children with CIs. By capturing score variations associated with age at implantation, auditory experience, and implantation laterality, the questionnaire provides meaningful insights into early post-implant outcomes and supports individualized rehabilitation planning. These findings highlight the value of the LEESPQ for early outcome assessment in pediatric cochlear implant users.