Ananyan Sampath

Mr. Ananyan Sampath

All India Institute of Medical Sciences Bhopal, Bhopal, India
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Journal of Education and Health Promotion
Verified
Journal Article
Open access
VMVarun Malhotra
Varun Malhotra
RSRagini Srivastava
Ragini Srivastava
PPPoovarasan Parasuraman
Poovarasan Parasuraman
DJDanish Javed
Danish Javed
SWSantosh Wakode
Santosh Wakode
AKAnkita Kumari
Ankita Kumari
BACKGROUND: The ancient Indian science of Yoga makes use of voluntary regulation of breathing to make respiration rhythmic and calm the mind. This practice is called pranayama. Nadisuddhi pranayama means “purification of subtle energy paths,” inhalation and exhalation are through alternative nostrils for successive respiratory cycles. Surya Anuloma-Viloma pranayama means “heat generating breathing particle” when the respiratory cycle of inhalation and exhalation is completed through the right nostril exclusively. When completed through the left nostril alone, the practice is called “Chandra Anuloma-Viloma pranayama,” which means a heat-dissipating or cooling liberating practice. We compared the effect of right nostril breathing (RNA) and left nostril breathing (LNB) pranayama on heart rate variability. MATERIALS AND METHODS: The study was conducted at the Department of Physiology at an institute of national importance, after obtaining necessary ethical approvals from the Institutional Ethics Committee. Twenty healthy kriya yogi volunteers (mean age: 44 years), who are regular practitioners for the last 10–20 years, were inducted into the study. RNB pranayama starts with closing the right nostril with the thumb of the left hand followed by exhalation through the right nostril and inhaling slowly through the same nostril. This forms one round of RNB pranayama. In contrast, inhalation through the left nostril and exhalation through the right nostril exclusively is called chandrabhedana pranayama (chandrabhedana means moon-piercing breath in Sanskrit) with a similar variation called Chandra Anuloma-Viloma pranayama in which inhalation, as well as exhalation, is performed through the left nostril exclusively. The recording of electrocardiogram (ECG) for heart rate variability (HRV) analysis was taken by heart rate variability (Dinamika HRV-Advanced Heart Rate Variability Test System, Moscow, Russia). The resting and during readings of heart rate variability parameters were compared and post hoc analysis was done using Bonferroni and Holm multiple comparisons for repeated measures. RESULTS: Time domain parameters: Standard deviation of normal to normal RR intervals (SDNN) and root mean square of successive NN interval differences (RMSSD) were increased at a high level of statistical significance during both pranayama maneuvres. Frequency domain parameters: LF, LF/HF ratio increased significantly. Parasympathetic activity is represented by LF when the respiration rate is lower than 7 breaths per min or during taking a deep breath. Thus, when the subject is in a state of relaxation with slow and even breathing in both RNB—right nostril and Chandra—LNB, the LF values can be very high, indicating an increase in parasympathetic activity rather than an increase in sympathetic regulation. CONCLUSION: Our study is an acute study, where changes in HRV were seen after 5 min of RNB and LNB. However, statistically, there is not much difference in the immediate effects of the two pranayamas on heart rate variability in regular yoga practitioners.

1 March 2023 in Personalized Medicine
Verified
Journal Article
Closed access
SDSayan Kumar Das
Sayan Kumar Das
Ananyan SampathAnanyan Sampath
Ananyan Sampath
SZSameer Uz Zaman
Sameer Uz Zaman
APAyan Kumar Pati
Ayan Kumar Pati
SAShubham Atal
Shubham Atal
Studies report an association between the expression of HLA alleles and lamotrigine (LTG)-induced Stevens–Johnson syndrome (SJS). This systematic review and meta-analysis evaluates the association ...

23 March 2023 in Medicinal Research Reviews
Verified
Journal Article
Closed access
Ananyan SampathAnanyan Sampath
Ananyan Sampath
ABAditya Banerjee
Aditya Banerjee
SAShubham Atal
Shubham Atal
RJRatinder Jhaj
Ratinder Jhaj

26 March 2024 in Cureus
Verified
Journal Article
Open access
PDF file
ARAvik Ray
Avik Ray
SAShubham Atal
Shubham Atal
SSSwati Sharma
Swati Sharma
Ananyan SampathAnanyan Sampath
Ananyan Sampath
Background Invasive blood sample collection followed by high-performance liquid chromatography (HPLC) based analysis is the gold standard for estimating glycated hemoglobin level or HbA1c currently. Spectrophotometry could be an alternative that holds the potential to be translated into a portable, non-invasive device for glycated hemoglobin level estimation. This study compares HbA1c values obtained from HPLC and spectrophotometry. Methods Venous blood samples were collected from both diabetic and non-diabetic participants in a cross-sectional study. The samples were subjected to both HPLC and spectrophotometry-based estimation of HbA1c%. The results obtained were compared, and the relationship between the two estimations were assessed. Results About 15 diabetic and non-diabetic individuals participated in the study and 28 samples were included in the final analysis. The Pearson’s correlation coefficient was 0.65 (95% CI, 0.37-0.82), indicating that there was a strong positive association. This was further supported by the findings from linear regression analysis with a p-value of <0.001. Conclusions The positive correlation between the HPLC and spectrophotometric values supports the hypothesis that spectrophotometry could be an alternative to conventional HPLC for the measurement of HbA1c. This needs to be further validated through larger, well-powered studies.

20 November 2022 in Cureus
Verified
Journal Article
Open access
Ananyan SampathAnanyan Sampath
Ananyan Sampath
SWSantosh Wakode
Santosh Wakode
RSRagini Shrivastava
Ragini Shrivastava
TPTanusha Pathak
Tanusha Pathak
ATAvinash Thakare
Avinash Thakare
NWNaina S. Wakode
Naina S. Wakode
Background: The recent coronavirus disease 2019 (COVID-19) pandemic, which swept across the globe in a short period, demonstrated that disease transmission management is a critical step in preventing an outbreak, as is good viral infectious disease screening. Infrared thermography (IRT) has long been considered ideal for screening body temperatures during pandemics. Methods: Single-centre cross-sectional study with 159 participants. Using infrared thermometry, participants were subjected to temperature measurement twice daily on various sites. This was compared to oral temperature. Results: The findings of the study revealed that infrared thermometry could be utilised as a proxy approach for screening by both individuals and medical professionals when employed at the glabella, cubits, or axillae. Conclusion: Temperature screening is implied as a prophylactic method during pandemics. Owing to contact limitations, oral thermometry cannot be used for mass screening during the pandemic. Infrared thermometry is a noncontact method of temperature screening that can readily be applied for mass temperature screening in congested venues such as airports, shopping malls, places of public convenience, and other similar locations.

15 March 2022 in Cureus
Verified
Journal Article
Open access
Ananyan SampathAnanyan Sampath
Ananyan Sampath
AKAvani Kulkarni
Avani Kulkarni
RGRevadi G
Revadi G
MPManmohan Patel
Manmohan Patel
BRBertha A Rathinam
Bertha A Rathinam
The ability of adaptation is unique to humankind. Technology advances have introduced many appliances that increasingly are smaller in size and handheld. These devices on prolonged usage affect the thumb joint complex, and this study was therefore designed to assess any changes in the movement of the thumb joint complex and fatigability secondary to the increasing usage of smartphones in different orientations in the Central Indian population. An analytical cross-sectional study was performed to assess changes in the ranges of motion (ROM) of the thumb joint complex with a sample size of 137 selected nonrandomly and categorized on the basis of the orientation of smartphone usage by physical goniometer and a standardized questionnaire to assess fatigability. Most movements of the thumb joint complex corresponded to the existing standard values. The study found significant changes in the movement of passive flexion of the left metacarpophalangeal (MCP) joint and borderline significant modifications in the active extension of the left interphalangeal (IP) joint, passive extension of the left interphalangeal joint, and passive flexion of the left carpometacarpal (CMC) joint among the groups of participants. The Borg CR10 value of fatigue was “one,” indicative of no excessive fatigue after smartphone usage. There are no significant changes in the ranges of motion of the joint complex of the thumb in mobile phone users over a period of time. The orientations and the increased duration of usage also did not cause any fatigue in the muscles of the thumb.