Anas Tarabsheh

Dr. Anas Tarabsheh

Associate Prof.
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
Muhammad AkmalMuhammad Akmal
Muhammad Akmal
MOHAMMED GHAZALMOHAMMED GHAZAL
MOHAMMED GHAZAL
As solar energy costs continue to drop, the number of large-scale deployment projects increases, and the need for different analysis models for photovoltaic (PV) modules in both academia and industry rises. This paper proposes a modified equivalent-circuit model for PV modules. A PV module comprises several series-connected PV cells, to generate more electrical power, where each PV cell has an internal shunt resistance. Our proposed model simplifies the standard one-diode equivalent-circuit (SEC) model by removing the shunt resistance and including its effect on the diode part of the circuit, while retaining the original model accuracy. Our proposed equivalent circuit, called here a modified SEC (MSEC), has less number of circuit elements. All of the PV cells are assumed operating under the same ambient conditions where they share the same electric voltage and current values. To ensure the simplification did not come at a reduction in the accuracy of the SEC model, we validate our MSEC model by simulating both under the same conditions, calculate, and compare their current/voltage (I/V) characteristics. Our results validate the accuracy of our model with the difference between the two models falling below 1%. Therefore, the proposed model can be adopted as an alternative representation of the equivalent circuit for PV cells and modules.

1 August 2016 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
IEIssa Etier
Issa Etier
HFHassan Fath
Hassan Fath
AGAbduallah Ghazal
Abduallah Ghazal
YMYousef Morci
Yousef Morci
AHAmgad El Haj
Amgad El Haj
Integrating cooling systems with photovoltaic (PV) modules represents a very important aspect of keeping modules within acceptable operating temperatures. The objective of this study is to analyse the performance of each series‐connected PV cell in photovoltaic thermal (PVT) modules. The importance of this analysis is due to the consideration of the variable operating temperature values of the PV cells, resulting in a different performance of each PV cell. The PVT modules are cooled with water serving as both a heat sink and a solar heat collector. This enhances the electrical efficiency value of the PVT modules by preventing them from elevated temperature values, while the recovered thermal energy can be utilised to increase the overall PV effectiveness. The new consideration in this study over the existing ones is the temperature distribution of each PV cell is applied for the calculation of the current voltage characteristics of the PV modules, which makes the analysis more accurate. The variance in the temperature values is a result of the temperature gradient of the fluid flowing through the pipes where the heat exchange differs in the flow direction. The potential of this study becomes more important for countries of high ambient temperatures and high solar intensity.

1 June 2019
Verified
Conference Paper
Closed access
Muhammad AkmalMuhammad Akmal
Muhammad Akmal
FAFaris Al-Naemi
Faris Al-Naemi
NINusrat Iqbal
Nusrat Iqbal
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
Lasantha MeegahapolaLasantha Meegahapola
Lasantha Meegahapola
Distributed generation (DG) has gained popularity among electricity end users who are determined to contribute to a cleaner environment by conforming to green and sustainable energy sources for various daily needs. The power system impact of such trends (e.g. roof-top solar-PV) need thorough investigation, such as impact on fault current levels on the distribution network. Varying fault current levels could adversely affect the operation of protection relays, which may lead to localized blackouts. Therefore, it is imperative to avoid localised blackouts due to mal-operation of protective relays under high penetration of DGs in distribution network. The focus of this research is to study the importance and implications of protective relays and over-current protection in the presence of distributed generation; where the impact of distributed generation on distribution network is identified. Relay coordination is observed to determine their operation characteristics to avoid mal-operation with the presence of DGs (e.g. solar-PV). This paper uses the UK generic distribution network model to simulate different scenarios in DIgSILENT Power Factory. The resulting power quality measures, such as voltage levels, short-circuit current levels and frequency are presented and discussed in the paper. The research highlights that small-scale DG penetration allows for existing protection infrastructure to continue operation and expensive upgrades for overall network are not required as fault levels remain the same.

1 June 2018
Verified
Conference Paper
Closed access
MAMarah Alhalabi
Marah Alhalabi
ARAbdelrahman Rashed
Abdelrahman Rashed
NINusrat Binte Iqbal
Nusrat Binte Iqbal
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
SiC power MOSFETs are an integral component of many electrical designs. At present, such designs are validated using various software tools such as Cadence and PSPICE. However, this paper proposes an improved model of the SiC Power MOSFET using MATLAB. The research aims to detail the mathematical formulation of the MOSFET in MATLAB followed by simulating the same in LTSpice and Simulink. The static and dynamic characteristics of the MOSFET are studied i.e. the effect of channel length modulation and temperature followed by the switching process throughout the different time periods is simulated and explained in detail. The paper concludes with an illustration of the results of the simulations obtained and the discussion based on them.

28 May 2012 in International Journal of Photoenergy
Verified
Journal Article
Open access
PDF file
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
IEI. Etier
I. Etier
ANA. Nimrat
A. Nimrat
This paper analyzes the energy yield of photovoltaic (PV) modules mounted on fixed tilt, one-axis, and two-axis tracking system towards maximizing the annual energy production. The performance evaluation of the proposed design of the tracking systems is carried via simulating the global radiation averages using METEONORM software and depicting the simulation results in figures using MATLAB software. The one-axis system is simulated by either fixing the azimuth angle while optimizing the inclination angles or fixing the inclination angle while optimizing the azimuth angles; simulation results show an increase in energy yield of 5.87% and 20.12% compared to that of fixed tilt system, respectively. In the two-axis system, optimization of both azimuth and inclination angles is carried out simultaneously which resulted in 30.82% improvement in energy yield. Therefore, 30% improvement in energy yield is directly reflected as saving in PV system cost due to reduction of the PV modules surface area.

1 March 2015 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
Anas TarabshehAnas Tarabsheh
Anas Tarabsheh
This paper presents a closed form for the behavior of the ideality factor n of amorphous silicon (a-Si:H) photovoltaic cells under different illumination intensity Φ levels and applied voltage V. The advantage of this model, over other existing models, is its effectiveness of describing the dependency of n on both V and Φ even without evaluating n itself. Therefore, the errors of calculating n using various existing methods are minimized in this paper. The variations of the current voltage J/V data under different levels of Φ are monitored where the illumination intensity dependence of parallel resistance Rp(Φ) is taken into account. The resulting model is a first order differential equation with non-constant coefficients whose solution expresses the variations of n in V- and Φ-domain. From the solution of the differential equation, it is found that n increases as V or Φ increases.