The seismic safety assessment of large concrete dams remains a significant challenge in dam engineering, as it requires appropriate analysis methods, modern performance criteria, and advanced numerical models to simulate the dam seismic behavior. This paper presents a method for seismic safety assessment of arch dams based on Endurance Time Analysis (ETA), using tensile and compressive damage results from a robust formulation for seismic analysis considering joint opening/sliding and concrete non-linear behavior (finite element program DamDySSA, under development in LNEC). The seismic performance is evaluated by controlling the evolution of the damage state of the dam, according to predefined performance criteria, to estimate acceleration endurance limits for tensile and compressive damage. These acceleration limits are compared, respectively, with the peak ground accelerations prescribed for the Operating Basis Earthquake (OBE) and Safety Evaluation Earthquake (SEE), aiming to evaluate the dam seismic performance relative to both earthquake levels efficiently, using a single intensifying acceleration time history. The ETA-based method is applied to the cases of Cabril Dam (132 m-high) and Cahora Bassa Dam (170 m-high), confirming its usefulness for future seismic safety studies, while the potential of DamDySSA for non-linear seismic analysis of arch dams is highlighted.
This paper is focused on the LNEC experience regarding the development and operation of continuous vibrations monitoring systems in large concrete dams. The goal is to emphasize the importance of the combined use of monitoring data and numerical models for Seismic and Structural Health Monitoring (SSHM) of Dams. The SSHM system installed in Cabril dam (132 m high), in operation since 2008, is described. The design and implementation of this system, including hardware and software, was the result of a long-term LNEC research program, still on-going. The SSHM system software was developed in order to automatically perform the analysis of collected data, including the automatic comparison with numerical results from 3DFE models. Similar systems have been installed in other large dams in Portugal.
This paper presents a formulation for the dynamic analysis of dam–reservoir–foundation systems, employing a coupled finite element model that integrates displacements and reservoir pressures. An innovative coupled approach, without separating the solid and fluid equations, is proposed to directly solve the single non-symmetrical governing equation for the whole system with non-proportional damping. For the modal analysis, a state–space method is adopted to solve the coupled eigenproblem, and complex eigenvalues and eigenvectors are computed, corresponding to non-stationary vibration modes. For the seismic analysis, a time-stepping method is applied to the coupled dynamic equation, and the stress–transfer method is introduced to simulate the nonlinear behavior, innovatively combining a constitutive joint model and a concrete damage model with softening and two independent scalar damage variables (tension and compression). This formulation is implemented in the computer program DamDySSA5.0, developed by the authors. To validate the formulation, this paper provides the experimental and numerical results in the case of the Cahora Bassa dam, instrumented in 2010 with a continuous vibration monitoring system designed by the authors. The good comparison achieved between the monitoring data and the dam–reservoir–foundation model shows that the formulation is suitable for simulating the modal response (natural frequencies and mode shapes) for different reservoir water levels and the seismic response under low-intensity earthquakes, using accelerograms measured at the dam base as input. Additionally, the dam’s nonlinear seismic response is simulated under an artificial accelerogram of increasing intensity, showing the structural effects due to vertical joint movements (release of arch tensions near the crest) and the concrete damage evolution.