Andrea Buscaroli

Prof. Dr. Andrea Buscaroli

Health Local Agency of Romagna, Ravenna, Emilia-Romagna, Italy
orcid
University of Bologna

Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2014 in American Journal of Transplantation
Verified
Journal Article
Open access
PDF file
IGI. Gandolfini
I. Gandolfini
CBC. Buzio
C. Buzio
PZP. Zanelli
P. Zanelli
APA. Palmisano
A. Palmisano
ECE. Cremaschi
E. Cremaschi
UMUmberto Maggiore
Umberto Maggiore
Pretransplant donor biopsy (PTDB)‐based marginal donor allocation systems to single or dual renal transplantation could increase the use of organs with Kidney Donor Profile Index (KDPI) in the highest range (e.g. >80 or >90), whose discard rate approximates 50% in the United States. To test this hypothesis, we retrospectively calculated the KDPI and analyzed the outcomes of 442 marginal kidney transplants (340 single transplants: 278 with a PTDB Remuzzi score <4 [median KDPI: 87; interquartile range (IQR): 78–94] and 62 with a score = 4 [median KDPI: 87; IQR: 76–93]; 102 dual transplants [median KDPI: 93; IQR: 86–96]) and 248 single standard transplant controls (median KDPI: 36; IQR: 18–51). PTDB‐based allocation of marginal grafts led to a limited discard rate of 15% for kidneys with KDPI of 80–90 and of 37% for kidneys with a KDPI of 91–100. Although 1‐year estimated GFRs were significantly lower in recipients of marginal kidneys (−9.3, −17.9 and −18.8 mL/min, for dual transplants, single kidneys with PTDB score <4 and =4, respectively; p < 0.001), graft survival (median follow‐up 3.3 years) was similar between marginal and standard kidney transplants (hazard ratio: 1.20 [95% confidence interval: 0.80–1.79; p = 0.38]). In conclusion, PTDB‐based allocation allows the safe transplantation of kidneys with KDPI in the highest range that may otherwise be discarded.

1 November 2010 in Transplantation Proceedings
Verified
Journal Article
Closed access
GBG. Bacchi
G. Bacchi
ABAndrea Buscaroli
Andrea Buscaroli
MFM. Fusari
M. Fusari
LNLuca Neri
Luca Neri
MCMaria Cappuccilli
Maria Cappuccilli
SSS. Stefoni
S. Stefoni

1 January 1990 in Nephron
Verified
Journal Article
Closed access
PDF file
DDDino Docci
Dino Docci
RBRenzo Bilancioni
Renzo Bilancioni
ABAndrea Buscaroli
Andrea Buscaroli
LBLeopoldo Baldrati
Leopoldo Baldrati
CCClaudio Capponcini
Claudio Capponcini
CFCarlo Feletti
Carlo Feletti
Serum C-reactive protein (CRP) levels were measured by nephelometry in 30 healthy subjects (controls) and in 99 patients with uncomplicated terminal uremia on conservative therapy (group 1, n = 30) or chronic hemodialysis (group 2, n = 69). Whereas there was no difference between controls and group 1, both the mean concentration of CRP and the incidence of elevated levels were significantly higher in group 2 in comparison with both controls and group 1. Moreover, the degree of increase in these patients was directly correlated with the duration of hemodialysis. The abnormality, therefore, is somehow related to chronic hemodialysis per se. From a practical standpoint, we concluded that this test cannot be recommended as an acute-phase reactant in this clinical setting.

1 January 1997 in Transplantation
Verified
Journal Article
Closed access
ACAlessandro Nanni Costa
Alessandro Nanni Costa
MSMaria Piera Scolari
Maria Piera Scolari
SISandra Iannelli
Sandra Iannelli
ABAndrea Buscaroli
Andrea Buscaroli
GDGiovanni Liviano D'ARcangelo
Giovanni Liviano D'ARcangelo
VBVittorio Bonomini
Vittorio Bonomini
Posttransplant monitoring of anti-HLA antibodies with routine techniques gives unsatisfactory results due to a variety of technical limitations. We investigated how a new alternative technique correlates with posttransplant clinical events. A total of 313 nonselected serum samples from 136 patients were screened by an ELISA utilizing captured soluble HLA class I antigens. We observed the absence of anti-HLA antibody production in acute rejection cases responding to standard antirejection therapy. On the other hand, we showed a clear presence of these antibodies in acute rejection episodes not responding to standard therapy (P<0.0001) and in chronic rejection (P<0.001). We conclude that routine posttransplant monitoring by ELISA offers early risk assessment that is crucial for proper immunosuppression and for antirejection therapy choice.

27 November 2013 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
PRPaola Rucci
Paola Rucci
MMM. Mandreoli
M. Mandreoli
Dino GibertoniDino Gibertoni
Dino Gibertoni
AZAlessandro Zuccalà
Alessandro Zuccalà
MFMaria Pia Fantini
Maria Pia Fantini
MFMarta Flachi
Marta Flachi
Registry-based studies have identified risk factors for chronic kidney disease (CKD) and for progression to end-stage renal disease. However, usually, these studies do not incorporate sequential measurements of kidney function and provide little information on the prognosis of individual patients. The aim of this study is to identify which combinations of demographic and clinical characteristics are useful to discriminate patients with a differential annual decline in glomerular filtration rate (GFR). This observational retrospective study includes patients enlisted in the registry of the Prevention of Progressive Renal Insufficiency Project of Emilia-Romagna region (Italy) from July 2004 to June 2010, with at least four serum creatinine measurements. Classification tree analysis (CTA) was used to identify subgroups of patients with a different annual GFR decline using demographic and laboratory data collected at study entry. The CTA procedure generated seven mutually exclusive groups. Among patients with proteinuria, those with a baseline estimated GFR (eGFR) of >33 mL/min/1.73 m2 exhibited the fastest illness progression in the study population (−3.655 mL/min/1.73 m2), followed by patients with a baseline eGFR of 4.3 mg/dL (−2.833 mL/min/1.73 m2). Among patients without proteinuria, those aged 67 years, females had on average a stable eGFR over time, with a large variability. It is possible to rely on a few variables typically accessible in routine clinical practice to stratify patients with a different CKD progression rate. Stratification can be used to guide decisions about the follow-up schedule, treatments to slow progression of kidney disease, prevent its complications and to begin planning for dialysis and transplantation.

1 May 1997 in Nephrology Dialysis Transplantation
Verified
Journal Article
Open access
PDF file
RWR. Ward
R. Ward
ABAndrea Buscaroli
Andrea Buscaroli
BSB. Schmidt
B. Schmidt
SSS. Stefoni
S. Stefoni
HGH J Gurland
H J Gurland
HKH. Klinkmann
H. Klinkmann
The solute removal characteristics and haemocompatibility of low-flux dialysers containing Cuprophan, cellulose acetate, polymethylmethacrylate (PMMA), and polycarbonate-polyether (Gambrane) membranes were compared in a multicentre cross-over clinical trial. While all four dialysers provided comparable removal of urea and creatinine, the dialyser containing PMMA membrane showed a reduced ability to remove phosphate compared to that containing Cuprophan membrane. Significant beta 2-microglobulin removal was obtained with the dialyser containing Gambrane membrane, whereas the other three dialysers had no impact on plasma beta 2-microglobulin concentrations. The ability to activate complement, measured as changes in the plasma concentrations of C3a des Arg and the terminal complement complex, and to produce leukopenia was greater for the dialyser containing Cuprophan membrane than for the other three. The ability to activate complement and cause leukopenia was not consistent among the remaining three dialysers and the degree of leukopenia could not be predicted from the level of complement activation. Neutrophil degranulation, as indicated by the release of elastase-alpha 1-proteinase inhibitor, occurred to a greater extent with the dialysers containing Cuprophan and Gambrane membranes. None of the dialysers was overtly thrombogenic as judged by changes in platelet count and plasma concentrations of the thrombin-antithrombin III complex. Our results demonstrate that although there are many similarities between dialysers containing low-flux membranes, there are also significant differences. These differences may enable improvements in therapy, while allowing continued use of low-flux dialysers.