Andrea Pace

Dr. Andrea Pace

University of Bologna, Bologna, Emilia-Romagna, Italy

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
RSRojin Shariati
Rojin Shariati
Donato CalabriaDonato Calabria
Donato Calabria
AEAfsaneh Emamiamin
Afsaneh Emamiamin
ELElisa Lazzarini
Elisa Lazzarini
APAndrea Pace
Andrea Pace
Mara MirasoliMara Mirasoli
Mara Mirasoli
Analytical chemistry applied to medical and diagnostic analysis has recently focused on the development of cost-effective biosensors able to monitor the health status or to assess the level of specific biomarkers that can be indicative of several diseases. The improvement of technologies relating to the possibility of the non-invasive sampling of biological fluids, as well as sensors for the detection of analytical signals and the computational capabilities of the systems routinely employed in everyday life (e.g., smartphones, computers, etc.), makes the complete integration of self-standing analytical devices more accessible. This review aims to discuss the biosensors that have been proposed in the last five years focusing on two principal detecting approaches, optical and electrochemical, which have been employed for quantifying different kinds of target analytes reaching detection limits below the clinical sample levels required. These detection principles applied to point-of-care (POC) devices have been extensively reported in literature, and even the limited examples found on the market are based on these strategies. This work will show the latest innovations considering the integration of optical and electrochemical detection with the most commonly reported analytical platforms for POC applications such as paper-based or wearable and implantable devices.

4 January 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
RSRojin Shariati
Rojin Shariati
Donato CalabriaDonato Calabria
Donato Calabria
AEAfsaneh Emamiamin
Afsaneh Emamiamin
ELElisa Lazzarini
Elisa Lazzarini
APAndrea Pace
Andrea Pace
Mara MirasoliMara Mirasoli
Mara Mirasoli
Wearable biosensors are attracting great interest thanks to their high potential for providing clinical-diagnostic information in real time, exploiting non-invasive sampling of biofluids. In this context, sweat has been demonstrated to contain physiologically relevant biomarkers, even if it has not been exhaustively exploited till now. This biofluid has started to gain attention thanks to the applications offered by wearable biosensors, as it is easily collectable and can be used for continuous monitoring of some parameters. Several studies have reported electrochemical and optical biosensing strategies integrated with flexible, biocompatible, and innovative materials as platforms for biospecific recognition reactions. Furthermore, sampling systems as well as the transport of fluids by microfluidics have been implemented into portable and compact biosensors to improve the wearability of the overall analytical device. In this review, we report and discuss recent pioneering works about the development of sweat sensing technologies, focusing on opportunities and open issues that can be decisive for their applications in routine-personalized healthcare practices.

9 October 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
Donato CalabriaDonato Calabria
Donato Calabria
MZMartina Zangheri
Martina Zangheri
ITIlaria Trozzi
Ilaria Trozzi
ELElisa Lazzarini
Elisa Lazzarini
APAndrea Pace
Andrea Pace
MGMassimo Guardigli
Massimo Guardigli
Microfluidic paper analytical devices (µPADs) represent one of the most appealing trends in the development of simple and inexpensive analytical systems for diagnostic applications at the point of care (POC). Herein, we describe a smartphone-based origami µPAD for the quantitative determination of glucose in blood samples based on the glucose oxidase-catalyzed oxidation of glucose leading to hydrogen peroxide, which is then detected by means of the luminol/hexacyanoferrate(III) chemiluminescent (CL) system. By exploiting the foldable µPAD format, a two-step analytical procedure has been implemented. First, the diluted blood sample was added, and hydrogen peroxide was accumulated, then the biosensor was folded, and a transport buffer was added to bring hydrogen peroxide in contact with CL reagents, thus promoting the CL reaction. To enable POC applicability, the reagents required for the assay were preloaded in the µPAD so that no chemicals handling was required, and a 3D-printed portable device was developed for measuring the CL emission using the smartphone’s CMOS camera. The µPAD was stable for 30-day storage at room temperature and the assay, displaying a limit of detection of 10 µmol L−1, proved able to identify both hypoglycemic and hyperglycemic blood samples in less than 20 min.

4 October 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
ELElisa Lazzarini
Elisa Lazzarini
APAndrea Pace
Andrea Pace
ITIlaria Trozzi
Ilaria Trozzi
MZMartina Zangheri
Martina Zangheri
MGMassimo Guardigli
Massimo Guardigli
Mara MirasoliMara Mirasoli
Mara Mirasoli
Food allergies are adverse health effects that arise from specific immune responses, occurring upon exposure to given foods, even if present in traces. Egg allergy is one of the most common food allergies, mainly caused by egg white proteins, with ovalbumin being the most abundant. As allergens can also be present in foodstuff due to unintended contamination, there is a need for analytical tools that are able to rapidly detect allergens in food products at the point-of-use. Herein, we report an origami paper-based device for detecting ovalbumin in food samples, based on a competitive immunoassay with chemiluminescence detection. In this biosensor, magnetic microbeads have been employed for easy and efficient immobilization of ovalbumin on paper. Immobilized ovalbumin competes with the ovalbumin present in the sample for a limited amount of enzyme-labelled anti-ovalbumin antibody. By exploiting the origami approach, a multistep analytical procedure could be performed using reagents preloaded on paper layers, thus providing a ready-to-use immunosensing platform. The assay provided a limit of detection (LOD) of about 1 ng mL−1 for ovalbumin and, when tested on ovalbumin-spiked food matrices (chocolate chip cookies), demonstrated good assay specificity and accuracy, as compared with a commercial immunoassay kit.

12 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Donato CalabriaDonato Calabria
Donato Calabria
MGMassimo Guardigli
Massimo Guardigli
PSPaolo Severi
Paolo Severi
ITIlaria Trozzi
Ilaria Trozzi
APAndrea Pace
Andrea Pace
Mara MirasoliMara Mirasoli
Mara Mirasoli
In recent years, there has been a continuously growing interest in antioxidants by both customers and food industry. The beneficial health effects of antioxidants led to their widespread use in fortified functional foods, as dietary supplements and as preservatives. A variety of analytical methods are available to evaluate the total antioxidant capacity (TAC) of food extracts and beverages. However, most of them are expensive, time-consuming, and require laboratory instrumentation. Therefore, simple, cheap, and fast portable sensors for point-of-need measurement of antioxidants in food samples are needed. Here, we describe a smartphone-based chemosensor for on-site assessment of TAC of aqueous matrices, relying on the antioxidant-induced formation of gold nanoparticles. The reaction takes place in ready-to-use analytical cartridges containing an hydrogel reaction medium preloaded with Au(III) and is monitored by using the smartphone’s CMOS camera. An analytical device including an LED-based lighting system was developed to ensure uniform and reproducible illumination of the analytical cartridge. The chemosensor permitted rapid TAC measurements of aqueous samples, including teas, herbal infusions, beverages, and extra virgin olive oil extracts, providing results that correlated with those of the reference methods for TAC assessment, e.g., oxygen radical absorbance capacity (ORAC).

14 June 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Donato CalabriaDonato Calabria
Donato Calabria
APAndrea Pace
Andrea Pace
ELElisa Lazzarini
Elisa Lazzarini
ITIlaria Trozzi
Ilaria Trozzi
MZMartina Zangheri
Martina Zangheri
Mara MirasoliMara Mirasoli
Mara Mirasoli
Chemiluminescence is widely used for hydrogen peroxide detection, mainly exploiting the highly sensitive peroxidase-luminol-H2O2 system. Hydrogen peroxide plays an important role in several physiological and pathological processes and is produced by oxidases, thus providing a straightforward way to quantify these enzymes and their substrates. Recently, biomolecular self-assembled materials obtained by guanosine and its derivatives and displaying peroxidase enzyme-like catalytic activity have received great interest for hydrogen peroxide biosensing. These soft materials are highly biocompatible and can incorporate foreign substances while preserving a benign environment for biosensing events. In this work, a self-assembled guanosine-derived hydrogel containing a chemiluminescent reagent (luminol) and a catalytic cofactor (hemin) was used as a H2O2-responsive material displaying peroxidase-like activity. Once loaded with glucose oxidase, the hydrogel provided increased enzyme stability and catalytic activity even in alkaline and oxidizing conditions. By exploiting 3D printing technology, a smartphone-based portable chemiluminescence biosensor for glucose was developed. The biosensor allowed the accurate measurement of glucose in serum, including both hypo- and hyperglycemic samples, with a limit of detection of 120 µmol L−1. This approach could be applied for other oxidases, thus enabling the development of bioassays to quantify biomarkers of clinical interest at the point of care.