Ane Goñi-Arana

Ms. Ane Goñi-Arana

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
GPG. Puyuelo-Quintana
G. Puyuelo-Quintana
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
APA. Plaza-Flores
A. Plaza-Flores
EGE. Garces-Castellote
E. Garces-Castellote
DSD. Sanz-Merodio
D. Sanz-Merodio
EGE. García-Armada
E. García-Armada
Background: Few portable exoskeletons following the assist-as-needed concept have been developed for patients with neurological disorders. Thus, the main objectives of this proof-of-concept study were 1) to explore the safety and feasibility of an exoskeleton for gait rehabilitation in stroke and multiple sclerosis patients, 2) to test different algorithms for gait assistance and measure the resulting gait changes and 3) to evaluate the user’s perception of the device. Methods: A cross-sectional study was conducted. Five patients were recruited (4 patients with stroke and 1 with multiple sclerosis). A robotic, one-degree-of-freedom, portable lower limb exoskeleton known as the Marsi Active Knee (MAK) was designed. Three control modes (the Zero Force Control mode, Mode 1 and Mode 3) were implemented. Spatiotemporal gait parameters were measured by the 10-m walking test (10MWT), the Gait Assessment and Intervention Tool (G.A.I.T.) and Tinetti Performance Oriented Mobility Assessment (gait subscale) before and after the trials. A modified QUEST 2.0 questionnaire was administered to determine each participant’s opinion about the exoskeleton. The data acquired by the MAK sensors were normalized to a gait cycle, and adverse effects were recorded. Results: The MAK exoskeleton was used successfully without any adverse effects. Better outcomes were obtained in the 10MWT and G.A.I.T. when Mode 3 was applied compared with not wearing the device at all. In 2 participants, Mode 3 worsened the results. Additionally, Mode 3 seemed to improve the 10MWT and G.A.I.T. outcomes to a greater extent than Mode 1. The overall score for the user perception of the device was 2.8 ± 0.4 95% CI. Conclusions: The MAK exoskeleton seems to afford positive preliminary results regarding safety, feasibility, and user acceptance. The efficacy of the MAK should be studied in future studies, and more advanced improvements in safety must be implemented.

23 January 2018 in Physical Review E
Verified
Journal Article
Open access
PDF file
RHR. C. Hidalgo
R. C. Hidalgo
AGAne Goñi-Arana
Ane Goñi-Arana
AHA. Hernández-Puerta
A. Hernández-Puerta
Ignacio PagonabarragaIgnacio Pagonabarraga
Ignacio Pagonabarraga
In this work, we numerically study a dense colloidal suspension flowing through a small outlet driven by a pressure drop using lattice-Boltzmann methods. This system shows intermittent flow regimes that precede clogging events. Several pieces of evidence suggest that the temperature controls the dynamic state of the system when the driving force and the aperture size are fixed. When the temperature is low, the suspension's flow can be interrupted during long time periods, which can be even two orders of magnitude larger than the system's characteristic time (Stokes). We also find that strong thermal noise does not allow the formation of stable aggregate structures avoiding extreme clogging events, but, at the same time, it randomizes the particle trajectories and disturbs the advective particle flow through the aperture. Moreover, examining the particle velocity statistics, we obtain that in the plane normal to the pressure drop the colloids always move as free particles regardless of the temperature value. In the pressure drop direction, at high temperature the colloids experience a simple balance between advective and diffusive transport, but at low temperature the nature of the flow is much more complex, correlating with the occurrence of very long clogging events.

28 November 2024 in Systematic Reviews
Verified
Journal Article
Open access
PDF file
AGAne Goñi-Arana
Ane Goñi-Arana
JPJorge Pérez-Martín
Jorge Pérez-Martín
FDFrancisco Javier Díez
Francisco Javier Díez
Breast thermography originated in the 1950s but was later abandoned due to the contradictory results obtained in the following decades. However, advances in infrared technology and image processing algorithms in the twenty-first century led to a renewed interest in thermography. This work aims to provide an updated and objective picture of the recent scientific evidence on its effectiveness, both as a screening and as a diagnostic tool. We searched for clinical studies published between 2001 and May 31, 2023, in the databases PubMed and Scopus, that aimed to evaluate the effectiveness of digital, long-wave infrared imaging for detecting breast cancer. Additional documents were retrieved from the studies included in the systematic reviews that resulted from the search and by searching for the names of commercial systems. We limited our selection to studies that reported the sensitivity and specificity of breast thermography (or the data needed to calculate them) using images collected by themselves, with at least five breast cancer cases. Studies that considered breast diseases other than cancer to be positive or that did not use standard tests to set the ground truth diagnosis were excluded, as well as articles written in a language other than English and documents we could not access. We also conducted meta-analyses of proportions of the sensitivity and specificity values reported in the selected studies and a bivariate meta-analysis to account for the correlation between these metrics. Our systematic search resulted in 22 studies, with an average pooled sensitivity and specificity of 88.5% and 71.8%, respectively. However, the differences in patient recruitment, sample size, imaging protocol, equipment, and interpretation criteria yielded a high heterogeneity measure (79.3% and 99.1% $${I}^{2}$$ value, respectively). Overall, thermography showed a high sensitivity in the selected studies, whereas specificity started off lower and increased over time. The most recent studies reported a combination of sensitivity and specificity comparable to standard diagnostic tests. Most of the selected studies were small and tend to include only patients with a suspicious mass that requires biopsy. However, larger studies with a wider variety of patient types (asymptomatic, women with dense breasts, etc.) have been published in the latest years.

18 September 2019
Verified
Book Chapter
Closed access
PDF file
DSDaniel Sanz-Merodio
Daniel Sanz-Merodio
GPGonzalo Puyuelo
Gonzalo Puyuelo
AGAmartya Ganguly
Amartya Ganguly
EGElena Garces
Elena Garces
AGAne Goñi-Arana
Ane Goñi-Arana
EGElena Garcia
Elena Garcia

1 October 2018
Verified
Conference Paper
Closed access
AGA. Ganguly
A. Ganguly
DSD. Sanz-Merodio
D. Sanz-Merodio
GPG. Puyuelo
G. Puyuelo
AGAne Goñi-Arana
Ane Goñi-Arana
EGE. Garces
E. Garces
EGE. Garcia
E. Garcia
This study reports the initial testing of a gait exoskeleton for Spinal Muscular Atrophy (SMA) patients having variable muscle strength with no balance or ambulation capabilities. To improve the quality of life of such patients, a pediatric gait exoskeleton was developed. The ATLAS exoskeleton has 8 active degrees of freedom (DOF): 2 at the hip (adduction/abduction and flexion/extension), 1 at the knee and ankle joint for flexion and extension. A feasibility test was performed to gauge the initial response of the patients. This study demonstrates that the exoskeleton was able to provide gait assistance and sit-to-stand movements effectively to the subjects. This kind of wearable exoskeleton will play a key role in the rehabilitation of SMA patients and delay further metabolic degeneration in the future.

29 June 2025 in Cancers
Verified
Journal Article
Open access
PDF file
AGAne Goñi-Arana
Ane Goñi-Arana
JPJorge Pérez-Martín
Jorge Pérez-Martín
FDFrancisco Javier Diez
Francisco Javier Diez
Thermography was first applied to breast cancer detection in the 1950s but fell out of favor among radiologists due to inconsistent and inconclusive findings in the following decades. Studies conducted in the 21st century using new-generation thermal cameras and computer vision techniques, particularly artificial intelligence, have reported sensitivity and specificity values comparable to those of mammography. However, most radiologists, being unaware of these results, still believe this technique is ineffective, and medical societies advise against using it, even as an adjunct to mammography. In this paper we review recent studies and discuss whether the recommendations of scientific societies are still valid in the light of new evidence. We also propose some ideas for standardizing breast thermography studies that could help make this technique acceptable to the radiology community.