Angie Fasoula

Dr. Angie Fasoula

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Academic Radiology
Verified
Journal Article
Open access
BMBrian M. Moloney
Brian M. Moloney
PMPeter F. McAnena
Peter F. McAnena
SESami M. Abd Elwahab
Sami M. Abd Elwahab
Angie FasoulaAngie Fasoula
Angie Fasoula
LDLuc Duchesne
Luc Duchesne
MKMichael J. Kerin
Michael J. Kerin
Microwave Breast Imaging (MBI) is an emerging non-ionising technology with the potential to detect breast pathology. The investigational device considered in this article is a low-power electromagnetic wave MBI prototype that demonstrated the ability to detect dielectric contrast between tumour phantoms and synthetic fibroglandular tissue in preclinical studies. Herein, we evaluate the MBI system in the clinical setting. The capacity of the MBI system to detect and localise breast tumours in addition to benign breast pathology is assessed. Secondly, the safety profile and patient experience of this device is established. Female patients were recruited from the symptomatic unit to 1 of 3 groups: Biopsy-proven breast cancers (Group-1), unaspirated cysts (Group-2) and biopsy-proven benign breast lesions (Group-3). Breast Density was determined by Volpara VDM (Volumetric Density Measurement) Software. MBI, radiological, pathological and histological findings were reviewed. Subjects were surveyed to assess patient experience. A total of 25 patients underwent MBI. 24 of these were included in final data analysis (11 Group-1, 8 Group-2 and 5 Group-3). The MBI system detected and localised 12 of 13 benign breast lesions, and 9 out of the 11 breast cancers. This included 1 case of a radiographically occult invasive lobular cancer. No device related adverse events were recorded. 92% (n = 23) of women reported that they would recommend MBI imaging to other women. The MBI system detected and localized the majority of breast lesions. This modality may have the potential to offer a non-invasive, non-ionizing and painless adjunct to breast cancer diagnosis. Further larger studies are required to validate the findings of this study.

1 May 2013 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
Angie FasoulaAngie Fasoula
Angie Fasoula
YAYohan Attal
Yohan Attal
DSDenis Pierre Schwartz
Denis Pierre Schwartz

18 August 2018 in Diagnostics
Verified
Journal Article
Open access
PDF file
Angie FasoulaAngie Fasoula
Angie Fasoula
LDLuc Duchesne
Luc Duchesne
JCJulio Daniel GIL CANO
Julio Daniel GIL CANO
PLPeter Lawrence
Peter Lawrence
GRGuillaume Robin
Guillaume Robin
JBJean-Gael Bernard
Jean-Gael Bernard
This paper presents the Wavelia microwave breast imaging system that has been recently installed at the Galway University Hospital, Ireland, for a first-in-human pilot clinical test. Microwave breast imaging has been extensively investigated over the last two decades as an alternative imaging modality that could potentially bring complementary information to state-of-the-art modalities such as X-ray mammography. Following an overview of the main working principles of this technology, the Wavelia imaging system architecture is presented, as are the radar signal processing algorithms that are used in forming the microwave images in which small tumors could be detectable for disease diagnosis. The methodology and specific quality metrics that have been developed to properly evaluate and validate the performance of the imaging system using complex breast phantoms that are scanned at controlled measurement conditions are also presented in the paper. Indicative results from the application of this methodology to the on-site validation of the imaging system after its installation at the hospital for pilot clinical testing are thoroughly presented and discussed. Given that the imaging system is still at the prototype level of development, a rigorous quality assessment and system validation at nominal operating conditions is very important in order to ensure high-quality clinical data collection.

26 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Angie FasoulaAngie Fasoula
Angie Fasoula
LDLuc Duchesne
Luc Duchesne
JCJulio Daniel GIL CANO
Julio Daniel GIL CANO
BMBrian M. Moloney
Brian M. Moloney
SESami M. Abd Elwahab
Sami M. Abd Elwahab
MKMichael J. Kerin
Michael J. Kerin
Microwave Breast Imaging (MBI) is an emerging non-ionizing imaging modality, with the potential to support breast diagnosis and management. Wavelia is an MBI system prototype, of 1st generation, which has recently completed a First-In-Human (FiH) clinical investigation on a 25-symptomatic patient cohort, to explore the capacity of the technology to detect and characterize malignant (invasive carcinoma) and benign (fibroadenoma, cyst) breast disease. Two recent publications presented promising results demonstrated by the device in this FiH study in detecting and localizing, as well as delineating size and malignancy risk, of malignant and benign palpable breast lesions. In this paper, the methodology that has been employed in the Wavelia semi-automated Quantitative Imaging Function (QIF), to support breast lesion detection and characterization in the FiH clinical investigation of the device, is presented and the critical design parameters are highlighted.

29 November 2021 in British Journal of Radiology
Verified
Journal Article
Open access
BMBrian M. Moloney
Brian M. Moloney
PMPeter McAnena
Peter McAnena
SESami M Elwahab
Sami M Elwahab
Angie FasoulaAngie Fasoula
Angie Fasoula
LDLuc Duchesne
Luc Duchesne
MKMichael J Kerin
Michael J Kerin
Objective: The Wavelia Microwave Breast Imaging (MBI) system, based on non-ionising imaging technology, has demonstrated exciting potential in the detection and localisation of breast pathology in symptomatic patients. In this study, the ability of the system to accurately estimate the size and likelihood of malignancy of breast lesions is detailed, and its clinical usefulness determined. Methods: Institutional review board and Health Products Regulatory Authority (HPRA) approval were obtained. Patients were recruited from the symptomatic unit to three groups; breast cancer (Group-1), unaspirated cysts (Group-2) and biopsied benign lesions (Group-3). MBI, radiological and histopathological findings were reviewed. MBI size estimations were compared with the sizes determined by conventional imaging and histopathology. A Quadratic Discriminant Analysis (QDA) classifier was trained in a 3D feature space to discriminate malignant from benign lesions. An independent review was performed by two independent breast radiologists. Results: 24 patients (11 Group-1, 8 Group-2 and 5 Group-3) underwent MBI. The Wavelia system was more accurate than conventional imaging in size estimation of breast cancers. The QDA accurately separated benign from malignant breast lesions in 88.5% of cases. The addition of MBI and the Wavelia malignancy risk calculation was deemed useful by the two radiologists in 70.6% of cases. Conclusion: The results from this MBI investigation demonstrate the potential of this novel system in estimating size and malignancy risk of breast lesions. This system holds significant promise as a potential non-invasive, comfortable, and harmless adjunct for breast cancer diagnosis. Further larger studies are under preparation to validate the findings of this study. Advances in knowledge: This study details the potential of the Wavelia MBI system in delineating size and malignancy risk of benign and malignant breast lesions in a symptomatic cohort. The usefulness of the Wavelia system is assessed in the clinical setting.

1 March 2020
Verified
Conference Paper
Closed access
Angie FasoulaAngie Fasoula
Angie Fasoula
LDL. Duchesne
L. Duchesne
BMB.M. Moloney
B.M. Moloney
JCJ.D. Gil Cano
J.D. Gil Cano
CCC. Chenot
C. Chenot
MKM.J. Kerin
M.J. Kerin