Antonio Scarano

Prof. Antonio Scarano

University of Chieti Pescara
+1
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2004 in Journal of Periodontology
Verified
Journal Article
Closed access
PDF file
Antonio ScaranoAntonio Scarano
Antonio Scarano
MPMaurizio Piattelli
Maurizio Piattelli
SCSergio Caputi
Sergio Caputi
GFGian Antonio Favero
Gian Antonio Favero
APAdriano Piattelli
Adriano Piattelli
Background: Little is known about the mechanisms of bacterial interaction with implant materials in the oral cavity. A correlation between plaque accumulation and progressive bone loss around implants has been reported. Bacterial adhesion shows a direct positive correlation with surface roughness. Other surface characteristics also seem to be extremely important with regard to plaque formation. Different adhesion affinities of bacteria have been reported for different materials. The aim of this study was to characterize the percentage of surface covered by bacteria on commercially pure titanium and zirconium oxide disks.Methods: Ten patients participated in this study. A removable acrylic device was adapted to the molar‐premolar region, and commercially pure titanium (control) and zirconium oxide (test) disks were glued to the buccal aspect of each device. The surface roughness of titanium and test specimens was similar. After 24 hours, all disks were removed and processed for scanning electron microscopy, for the evaluation of the portion of surface covered by bacteria.Results: In control specimens, the area covered by bacteria was 19.3% ± 2.9; in test specimens, the area was 12.1% ± 1.96. The disk surface covered by bacteria on test specimens was significantly lower than that of control specimens (P = 0.0001).Conclusion: Our results demonstrate that zirconium oxide may be a suitable material for manufacturing implant abutments with a low colonization potential. J Periodontol 2004;75:292‐296.

1 November 2001 in Journal of Periodontology
Verified
Journal Article
Closed access
PDF file
MPMichele Paolantonio
Michele Paolantonio
MDMarco Dolci
Marco Dolci
Antonio ScaranoAntonio Scarano
Antonio Scarano
DDDomenico D'ARchivio
Domenico D'ARchivio
GPGiacinto Di Placido
Giacinto Di Placido
APAdriano Piattelli
Adriano Piattelli
Background: Early implantation may preserve the alveolar anatomy, and the placement of a fixture in a fresh extraction socket helps to maintain the bony crest. Although a number of clinical studies exist, no histological reports show the outcome of implantation in fresh extraction sockets without the use of membranes in humans compared to implants placed in mature bone.Methods: Forty‐eight healthy patients, receiving at least 4 fixtures in each of 2 symmetrical quadrants, underwent placement of 1 experimental fixture placed in a fresh extraction socket (TI) and 1 contralateral fixture in mature bone (CI). TI were placed after atraumatical tooth extraction, with a surgical site at the apex of the socket and a tight contact between the fixture and the socket's walls, but without the use of filling materials or membranes. The flap was coronally repositioned to obtain primary wound closure. Immediately after surgical intervention, a standardized periapical radiograph was taken. Second‐stage surgery was done after 6 months. Six months after the second surgery, a second standardized periapical radiograph was taken and clinical parameters (bleeding and plaque index) recorded. Marginal bone loss (MBL) from the time of implant placement to the time of fixture removal was calculated by comparing periapical radiographs. TI and CI were then removed by a hollow drill to obtain histological specimens. Non‐demineralized sections were stained by acid fuchsin and toluidine blue, and by von Kossa to evaluate the degree of bone mineralization. The percentage of direct implant‐bone contact (DBC) was calculated by a computerized microscopic digitizer.Results: No significant differences in the clinical and radiographic parameters were observed between the 2 experimental categories. There was no statistically significant difference between TI and CI for DBC either in the maxilla or in the mandible. No connective or fibrous tissues were present around TI or CI. Bone resorption was not present in any of the histological sections.Conclusions: The present study shows that when a screw‐type dental implant is placed without the use of barrier membranes or other regenerative materials into a fresh extraction socket with a bone‐to‐implant gap of 2 mm or less, the clinical outcome and degree of osteointegration does not differ from implants placed in healed, mature bone. J Periodontol 2001;72:1560‐1571.

1 January 2006 in Journal of Periodontology
Verified
Journal Article
Closed access
PDF file
MDMarco Degidi
Marco Degidi
LALuciano Artese
Luciano Artese
Antonio ScaranoAntonio Scarano
Antonio Scarano
Vittoria PerrottiVittoria Perrotti
Vittoria Perrotti
PGPeter Gehrke
Peter Gehrke
APAdriano Piattelli
Adriano Piattelli
Background: The aim of the present study in humans was to conduct a comparative immunohistochemical evaluation of vascular endothelial growth factor (VEGF) and nitric oxide synthase (NOS) expression, inflammatory infiltrate, proliferative activity expression, and microvessel density (MVD) in peri‐implant soft tissues of titanium and zirconium oxide healing caps.Methods: Five patients, three men and two women (aged 30 to 66 years; mean: 49 years), participated in this study. All patients received dental implants that were 3.8 mm in diameter and 11 mm in length. All implants were left to heal in a non‐submerged (single‐stage) mode. Healing caps (3.8 mm in diameter and 3.0 mm in height) were inserted in all implants. Half of the implants were supplied with standard, prefabricated caps of commercially pure titanium, whereas the other half were provided with test zirconium oxide caps. After a 6‐month healing period, a gingival biopsy was performed with a circular scalpel (5.5 mm in diameter) around the healing caps of both groups, without unscrewing or removing the healing caps. The dimensions of the gingival biopsies were 1.7 mm (5.5 − 3.8 mm) in thickness and 3 mm in height.Results: Statistically significant differences were found in the microvessel density between titanium and zirconium oxide healing caps and group II (P ≤0.0001). Statistically significant differences were likewise found in the low and high intensities of NOS1, NOS3, and VEGF (P ≤0.0001). In conclusion, the high intensity of NOS1, NOS3, and VEGF were mostly expressed in the titanium group, whereas the low intensity of NOS1, NOS3, and VEGF were mostly expressed in the zirconium oxide group.Conclusions: In our specimens, the inflammatory infiltrate was mostly present in the titanium specimens. Their extension was much larger than that of the zirconium oxide specimens. Higher values of MVD were observed in the titanium specimens (29.1 versus 15.8). In addition, a higher expression of VEGF intensity was observed in the peri‐implant tissues of titanium healing caps, whereas predominantly lower expressions of VEGF intensity were noted around the zirconium oxide healing caps. The Ki‐67 expression was higher in the titanium specimens. All these data revealed that the tissues around titanium healing caps underwent a higher rate of inflammation‐associated processes, most probably correlated to the higher inflammation processes observed in these tissues. A higher intensity expression of NOS1 and NOS3 was recorded in the tissues around titanium, whereas, on the contrary, a lower intensity of expression was found in the tissues around zirconium oxide specimens. These latter data indicate that the higher expression of these two mediators could be correlated to the higher amount of bacteria present around the titanium samples.

Antonio ScaranoAntonio Scarano
Antonio Scarano
Francesco InchingoloFrancesco Inchingolo
Francesco Inchingolo
Felice LorussoFelice Lorusso
Felice Lorusso
Individual respiratory protective devices and face masks represent critical tools in protecting health care workers in hospitals and clinics, and play a central role in decreasing the spread of the high-risk pandemic infection of 2019, coronavirus disease (COVID-19). The aim of the present study was to compare the facial skin temperature and the heat flow when wearing medical surgical masks to the same factors when wearing N95 respirators. A total of 20 subjects were recruited and during the evaluation, each subject was invited to wear a surgical mask or respirator for 1 h. The next day in the morning at the same hour, the same subject wore a N95 mask for 1 h with the same protocol. Infrared thermal evaluation was performed to measure the facial temperature of the perioral region and the perception ratings related to the humidity, heat, breathing difficulty, and discomfort were recorded. A significant difference in heat flow and perioral region temperature was recorded between the surgical mask and the N95 respirator (p < 0.05). A statistically significant difference in humidity, heat, breathing difficulty, and discomfort was present between the groups. The study results suggest that N95 respirators are able to induce an increased facial skin temperature, greater discomfort and lower wearing adherence when compared to the medical surgical masks.

1 June 2006 in Implant Dentistry
Verified
Journal Article
Closed access
Antonio ScaranoAntonio Scarano
Antonio Scarano
MDMarco Degidi
Marco Degidi
GIGiovanna Iezzi
Giovanna Iezzi
GPGabriele Pecora
Gabriele Pecora
MPMaurizio Piattelli
Maurizio Piattelli
APAdriano Piattelli
Adriano Piattelli
Rehabilitation of the edentulous posterior maxilla with dental implants can be difficult because of insufficient bone volume caused by pneumatization of the maxillary sinus and crestal bone resorption. Different biomaterials have been used for sinus augmentation. The aim of the study was to compare different materials in maxillary sinus augmentation in man. A total of 94 patients participated in this study. Inclusion criteria were maxillary partial (unilateral or bilateral) edentulism involving the premolar/molar areas, and the presence of 3–5-mm crestal bone between the sinus floor and alveolar ridge. A total of 362 implants were inserted. There were 9 biomaterials used in the sinus augmentation procedures. Each patient underwent 1 biopsy after 6 months. A total of 144 specimens were retrieved. None of the 94 patients had complications. All implants were stable, and x-ray examination showed dense bone around the implants. Mean follow-up was 4 years. There were 7 implants that failed. Histologic resultsshowed that almost all the particles of the different biomaterials (i.e., autologous bone, demineralized freeze-dried bone allograft Biocoral® [Inoteb, St. Gonnery, France], Bioglass® [US Biomaterials, Alachua, FL], Fisiograft® [Ghimas, Bologna, Italy], PepGen P-15TM [Dentsply Friadent CeraMed, Lakewood, CO], calcium sulfate, Bio-Oss® [Geistlich Pharma AG, Wohlhusen, Switzerland], and hydroxyapatite) were surrounded by bone. Some biomaterials were more resorbable than others. Included are the histomorphometry clarified features of the newly formed bone around the different grafted particles. All biomaterials examined resulted in being biocompatible and seemed to improve new bone formation in maxillary sinus lift. No signs of inflammation were present. The data are very encouraging because of the high number of successfully treated patients and the good quality of bone found in the retrieved specimens.

1 February 2003 in Journal of Oral Implantology
Verified
Journal Article
Closed access
Antonio ScaranoAntonio Scarano
Antonio Scarano
FCFabio Di Carlo
Fabio Di Carlo
MQManlio Quaranta
Manlio Quaranta
APAdriano Piattelli
Adriano Piattelli
This study analyzes the bone response to zirconia ceramic implants inserted in New Zealand white mature male rabbits. The implants were inserted into the tibia, and each rabbit received 4 implants. All the animals were euthanatized after 4 weeks. A total of 20 implants were retrieved. Implants and surrounding tissues were immediately fixed in 4% paraformaldehyde and 0.1% glutaraldehyde in 0.15 molar cacodylate buffer at 4°C and pH 7.4 to be processed for histology. The specimens were processed to obtain thin ground sections with the Precise 1 Automated System. The slides were observed in normal transmitted light under a Leitz Laborlux microscope. A great quantity of newly formed bone was observed in close contact with zirconia ceramic surfaces; in some areas, many osteoblasts were present directly on the zirconia. Percentage of bone-implant contact was 68.4% ± 2.4%. Mature bone, with few marrow spaces, was present. Small actively secreting osteoblasts were present in the most coronal and apical p...