Arturo Javier Martinez-Mata

Dr. Arturo Javier Martinez-Mata

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
Arturo Javier Martinez-MataArturo Javier Martinez-Mata
Arturo Javier Martinez-Mata
ABA Blanco-Ortega
A Blanco-Ortega
CGCh Guzmán-Valdivia
Ch Guzmán-Valdivia
AAA Abúndez-Pliego
A Abúndez-Pliego
MGMa García-Velarde
Ma García-Velarde
ROR Osorio-Sánchez
R Osorio-Sánchez
In the industrial and military sector, work activities are required transporting or supporting heavy loads manually, affecting this the human spinal column due to the weight of the loads or the repetition of this labor. In this regard, the use of force-enhancing exoskeletons is a potential solution to this issue. Therefore, this article summarizes the state of the art in relevant contributions to structural design, control systems, actuators, and performance metrics to evaluate the proper functioning of exoskeletons used for load support and transfer. This is essential to address current and new open problems in these applications, and this includes reducing the metabolic cost and enhancing the loading force in exoskeletons, in which challenges such as structural design and kinetic interactions between the human and the robot are presented. The systematic review of the strategies found in the literature helps addressing these challenges in an orderly way. The proposal of some alternative solutions could help to solving some of the challenges mentioned above, as well as further research to improve the design of these devices is necessary.

21 May 2025 in Computation
Verified
Journal Article
Open access
PDF file
ASAgustin Barrera Sánchez
Agustin Barrera Sánchez
Rafael Campos AmezcuaRafael Campos Amezcua
Rafael Campos Amezcua
HRHéctor R. Azcaray Rivera
Héctor R. Azcaray Rivera
Arturo Javier Martinez-MataArturo Javier Martinez-Mata
Arturo Javier Martinez-Mata
Andres Blanco OrtegaAndres Blanco Ortega
Andres Blanco Ortega
CGCesar H. Guzmán-Valdivia
Cesar H. Guzmán-Valdivia
Nowadays, the use of biomechanical devices in medical processes and industrial applications allows us to perform tasks in a simpler and faster way. In the medical field, these devices are becoming more and more common, especially in therapeutic applications. In the design and development of orthopedic devices, it is essential to consider the limbs’ kinematic, kinetic, and anthropometric conditions, as well as the implementation of control strategies (robust, PID, fuzzy, and impedance, among others). This work presents a virtual prototype of a knee orthosis and the implementation of a control system to follow a desired trajectory. Results are presented with the virtual prototype through a co-simulation between MSC Adams and MATLAB Simulink with fuzzy control, virtually replicating the gait cycle.

19 November 2025 in Automation
Verified
Journal Article
Open access
PDF file
CVCesar Humberto Guzmán Valdivia
Cesar Humberto Guzmán Valdivia
HAHéctor R. Azcaray-Rivera
Héctor R. Azcaray-Rivera
Arturo Javier Martinez-MataArturo Javier Martinez-Mata
Arturo Javier Martinez-Mata
JMJorge Aurelio Brizuela Mendoza
Jorge Aurelio Brizuela Mendoza
HAHéctor Mguel Arias
Héctor Mguel Arias
Andres Blanco OrtegaAndres Blanco Ortega
Andres Blanco Ortega
Dip coating is a widely used laboratory method for depositing thin films and functional coatings. However, commercial dip-coaters remain costly and often exceed the needs of teaching labs and early-stage research. This paper presents a simple, low-cost automated dip-coater capable of delivering repeatable rise–dwell–fall motion for benchtop applications. The system integrates a 3D-printed PLA structure, a stepper-lead-screw actuator, and a PC-hosted graphical user interface that learns and executes user-specified trajectories without additional hardware controls. A compact mathematical model generates triangular and trapezoidal profiles and maps them to step pulses via the steps-per-millimeter factor. The mechatronic design and sequential control are described, and the prototype is validated through simulations and experiments. Non-contact measurements demonstrate high repeatability, accurate dwell timing, and bounded accelerations with minor deviations at switching instants. The bill of materials is 50 USD (≈1–2% of entry-level commercial systems), underscoring stability, robustness, and accessibility for instructional and resource-constrained settings. These results indicate strong potential for routine laboratory use and a clear path to future enhancements.

8 July 2025 in Technologies
Verified
Journal Article
Open access
PDF file
Filiberto Cruz FloresFiliberto Cruz Flores
Filiberto Cruz Flores
A. Sanchez-BritoA. Sanchez-Brito
A. Sanchez-Brito
Rafael Campos AmezcuaRafael Campos Amezcua
Rafael Campos Amezcua
ASAgustin Barrera Sánchez
Agustin Barrera Sánchez
HRHéctor R. Azcaray Rivera
Héctor R. Azcaray Rivera
Andres Blanco OrtegaAndres Blanco Ortega
Andres Blanco Ortega
This article presents a comprehensive review of assistive devices for synovial joints, addressing their definitions, classifications, and technological advancements. The historical evolution of artificial exoskeletons, orthoses, prostheses, and splints is analyzed, emphasizing their impact on rehabilitation and the enhancement of human mobility. Through a systematic compilation of scientific literature, patents, and medical regulations, the study clarifies terminology and classifications that have often been imprecisely used in scientific discourse. The review examines the biomechanical principles of the musculoskeletal system and the kinematics of synovial joints, providing a reference framework for the optimization and design of these devices. Furthermore, it explores the various types of artificial exoskeletons, and their classification based on structure, mobility, power source, and control system, as well as their applications in medical, industrial, and military domains. Finally, this study highlights the necessity of a systematic approach in the design and categorization of these technologies to facilitate their development, comparison, and effective implementation, ultimately improving users’ quality of life.

1 October 2026 in REVISTA DE CIENCIAS TECNOLÓGICAS
Verified
Journal Article
Open access
PDF file
LQLuis Alfonso Manzanares Quirós
Luis Alfonso Manzanares Quirós
Andres Blanco OrtegaAndres Blanco Ortega
Andres Blanco Ortega
Rafael Campos AmezcuaRafael Campos Amezcua
Rafael Campos Amezcua
EAEnrique Alcudia-Zacarias
Enrique Alcudia-Zacarias
APArturo Abundez Pliego
Arturo Abundez Pliego
Arturo Javier Martinez-MataArturo Javier Martinez-Mata
Arturo Javier Martinez-Mata
El temblor de mano es el movimiento involuntario más común provocado por enfermedades neurodegenerativas asociadas a la edad y trastornos de movimiento, como la enfermedad de párkinson y el temblor esencial, reconocido por ser el trastorno de movimiento más común entre la población de edad avanzada, afectado un 0.9% de la población mundial, la principal característica del temblor esencial, es el temblor cinético, el cual aparece en la realización de movimientos voluntarios en actividades cotidianas, como lo son, la escritura, comer y beber. En este trabajo se presenta el análisis del temblor de mano capturado en video usando el software Kinovea, posteriormente se utilizó dicho análisis para desarrollar un entorno virtual de simulación en el software MSC Adams View, con el propósito de integrar estos programas en el desarrollo de prototipos y técnicas de control para la supresión del temblor de mano, en este artículo se simuló la influencia del temblor en la muñeca en reposo y durante una acción voluntaria, también se simuló la acción de un exoesqueleto implementado un control PD para suprimir el temblor, obteniendo un 99.63% de supresión de movimientos con frecuencias dentro del rango característico del temblor (4 a 12Hz).

31 December 2024 in Computation
Verified
Journal Article
Open access
PDF file
OPOscar Ivan Cirilo Piñon
Oscar Ivan Cirilo Piñon
ASAgustin Barrera Sánchez
Agustin Barrera Sánchez
CVCesar Humberto Guzmán Valdivia
Cesar Humberto Guzmán Valdivia
MMManuel Adam Medina
Manuel Adam Medina
Rafael Campos AmezcuaRafael Campos Amezcua
Rafael Campos Amezcua
Arturo Javier Martinez-MataArturo Javier Martinez-Mata
Arturo Javier Martinez-Mata
An ankle sprain can be caused by daily activities such as running, walking, or playing sports. In many cases, the patient’s ankle suffers severe or permanent damage that requires rehabilitation to return to its initial state. Thanks to technological advances, robotics has allowed for the development of machines that generate precise, efficient, and safe movements. In addition, these machines are manipulated by a specific control depending on the rehabilitation objective. Impedance control is used in ankle rehabilitation machines for active–resistive-type rehabilitation, where the patient participates by exerting a force on the machine repeatedly. Serious games are an example of an activity where the patient can interact with a video game while rehabilitating. Currently, most machines involving impedance control and targeted at serious gaming applications are mechanically composed of one degree of freedom, so the addition of another degree is a novelty. This paper presents simulation results comparing different impedance controls reported in the literature to determine the best option for applying a 2-DOF ankle rehabilitation machine using serious games. The results obtained are presented by comparing them according to the force applied to the rehabilitation machine (emulating the behavior of a patient). From the impedance controllers analyzed for horizontal (abduction/adduction) and vertical (dorsiflexion/plantarflexion) movements in the rehabilitation machine, it was determined that the PD control, which considers some mechanical parameters, presents a better performance. With this controller, fast and smooth angular movements are generated, while the consumption of kinetic energy is kept in a low range, proportional to the applied forces, compared to the other impedance controls analyzed.