Asad Mirza

Dr. Asad Mirza

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
CHChia-Pei Denise Hsu
Chia-Pei Denise Hsu
ATAlexandra Tchir
Alexandra Tchir
AMAsad Mirza
Asad Mirza
DCDaniel Chaparro
Daniel Chaparro
RHRaul E. Herrera
Raul E. Herrera
Sharan RamaswamySharan Ramaswamy
Sharan Ramaswamy
The aortic valve facilitates unidirectional blood flow to the systemic circulation between the left cardiac ventricle and the aorta. The valve’s biomechanical function relies on thin leaflets to adequately open and close over the cardiac cycle. A monolayer of valve endothelial cells (VECs) resides on the outer surface of the aortic valve leaflet. Deeper within the leaflet are sublayers of valve interstitial cells (VICs). Valve tissue remodeling involves paracrine signaling between VECs and VICs. Aortic valve calcification can result from abnormal paracrine communication between these two cell types. VECs are known to respond to hemodynamic stimuli, and, specifically, flow abnormalities can induce VEC dysfunction. This dysfunction can subsequently change the phenotype of VICs, leading to aortic valve calcification. However, the relation between VEC-exposed flow oscillations under pulsatile flow to the progression of aortic valve calcification by VICs remains unknown. In this study, we quantified the level of flow oscillations that VECs were exposed to under dynamic culture and then immersed VICs in VEC-conditioned media. We found that VIC-induced calcification was augmented under maximum flow oscillations, wherein the flow was fully forward for half the cardiac cycle period and fully reversed for the other half. We were able to computationally correlate this finding to specific regions of the aortic valve that experience relatively high flow oscillations and that have been shown to be associated with severe calcified deposits. These findings establish a basis for future investigations on engineering calcified human valve tissues and its potential for therapeutic discovery of aortic valve calcification.

16 June 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AMAsad Mirza
Asad Mirza
Sharan RamaswamySharan Ramaswamy
Sharan Ramaswamy
The Newtonian model has commonly been used to represent the viscosity of blood in the aorta, despite blood itself being a non-Newtonian fluid. This is justified where shear rates tend to be large. However, we hypothesized that using the Newtonian model to predict the hemodynamics on the aortic valve, particularly in those with severe calcifications, is inaccurate owing to valve leaflet geometry irregularities inducing multiple regions of low shear rates, 100 s-1, use of a Newtonian model was justified for the ventricularis side of the leaflet. However, in spatial regions of low shear rates, <100 s-1, specifically on the inner cusps of the fibrosa side of the valve, TAWSS calculations under a Newtonian model were found to be much lower when compared with their non-Newtonian Carreau and Quemada counterparts. We hereby conclude that in order to facilitate more accurate computational flow simulations in severe aortic valve calcification which is subjected to relatively large spatial regions of low shear (<100 s-1), a non-Newtonian model should be applied.

7 May 2019 in Bioengineering
Verified
Journal Article
Open access
PDF file
MTMelake D. Tesfamariam
Melake D. Tesfamariam
AMAsad Mirza
Asad Mirza
DCDaniel Chaparro
Daniel Chaparro
AAAhmed Z. Ali
Ahmed Z. Ali
RMRachel Montalvan
Rachel Montalvan
Sharan RamaswamySharan Ramaswamy
Sharan Ramaswamy
The progression of calcific aortic valve disease (CAVD) is characterized by extracellular matrix (ECM) remodeling, leading to structural abnormalities and improper valve function. The focus of the present study was to relate aortic valve leaflet axial curvature changes as a function of elastin degradation, which has been associated with CAVD. Circumferential rectangular strips (L × W = 10 × 2.5 mm) of normal and elastin-degraded (via enzymatic digestion) porcine AV leaflets were subjected to cyclic flexure (1 Hz). A significant increase in mean curvature (p < 0.05) was found in elastin-degraded leaflet specimens in comparison to un-degraded controls at both the semi-constrained (50% of maximum flexed state during specimen bending and straightening events) and fully-constrained (maximally-flexed) states. This significance did not occur in all three flexed configurations when measurements were performed using either minimum or maximum curvature. Moreover, the mean curvature increase in the elastin-degraded leaflets was most pronounced at the instance of maximum flexure, compared to un-degraded controls. We conclude that the mean axial curvature metric can detect distinct spatial changes in aortic valve ECM arising from the loss in bulk content and/or structure of elastin, particularly when there is a high degree of tissue bending. Therefore, the instance of maximum leaflet flexure during the cardiac cycle could be targeted for mean curvature measurements and serve as a potential biomarker for elastin degradation in early CAVD remodeling.

13 June 2024 in Materials Today Bio
Verified
Journal Article
Open access
ZXZhuotao Xiao
Zhuotao Xiao
RPRudmer Postma
Rudmer Postma
AZAnton Jan van Zonneveld
Anton Jan van Zonneveld
BBBernard M. van den Berg
Bernard M. van den Berg
WSWendy M.P.J. Sol
Wendy M.P.J. Sol
JRJoris I. Rotmans
Joris I. Rotmans
Disturbed flow is one of the pathological initiators of endothelial dysfunction in intimal hyperplasia (IH) which is commonly seen in vascular bypass grafts, and arteriovenous fistulas. Various in vitro disease models have been designed to simulate the hemodynamic conditions found in the vasculature. Nonetheless, prior investigations have encountered challenges in establishing a robust disturbed flow model, primarily attributed to the complex bifurcated geometries and distinctive flow dynamics. In the present study, we aim to address this gap by introducing an in vitro bypass flow model capable of inducing disturbed flow and other hemodynamics patterns through a pulsatile flow in the same model. To assess the model's validity, we employed computational fluid dynamics (CFD) to simulate hemodynamics and compared the morphology and functions of human umbilical venous endothelial cells (HUVECs) under disturbed flow conditions to those in physiological flow or stagnant conditions. CFD analysis revealed the generation of disturbed flow within the model, pinpointing the specific location in the channel where the effects of disturbed flow were observed. High-content screening, a single-cell morphological profile assessment, demonstrated that HUVECs in the disturbed flow area exhibited random orientation, and morphological features were significantly distinct compared to cells in the physiological flow or stagnant condition after a two days of flow exposure. Furthermore, HUVECs exposed to disturbed flow underwent extensive remodeling of the adherens junctions and expressed higher levels of endothelial cell activation markers compared to other hemodynamic conditions. In conclusion, our in vitro bypass flow model provides a robust platform for investigating the associations between disturbed flow pattern and vascular diseases.

24 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
AMAsad Mirza
Asad Mirza
CHChia-Pei Denise Hsu
Chia-Pei Denise Hsu
ARAndres Rodriguez
Andres Rodriguez
PAPaulina Alvarez
Paulina Alvarez
Lihua LouLihua Lou
Lihua Lou
Joshua D HutchesonJoshua D Hutcheson
Joshua D Hutcheson
Heart disease is a leading cause of mortality, with calcific aortic valve disease (CAVD) being the most prevalent subset. Being able to predict this disease in its early stages is important for monitoring patients before they need aortic valve replacement surgery. Thus, this study explored hydrodynamic, mechanical, and hemodynamic differences in healthy and very mildly calcified porcine small intestinal submucosa (PSIS) bioscaffold valves to determine any notable parameters between groups that could, possibly, be used for disease tracking purposes. Three valve groups were tested: raw PSIS as a control and two calcified groups that were seeded with human valvular interstitial and endothelial cells (VICs/VECs) and cultivated in calcifying media. These two calcified groups were cultured in either static or bioreactor-induced oscillatory flow conditions. Hydrodynamic assessments showed metrics were below thresholds associated for even mild calcification. Young’s modulus, however, was significantly higher in calcified valves when compared to raw PSIS, indicating the morphological changes to the tissue structure. Fluid–structure interaction (FSI) simulations agreed well with hydrodynamic results and, most notably, showed a significant increase in time-averaged wall shear stress (TAWSS) between raw and calcified groups. We conclude that tracking hemodynamics may be a viable biomarker for early-stage CAVD tracking.

20 October 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
BGBrittany A. Gonzalez
Brittany A. Gonzalez
AHAriadna Herrera
Ariadna Herrera
CPClaudia Ponce
Claudia Ponce
MPMarcos Gonzalez Perez
Marcos Gonzalez Perez
CHChia-Pei Denise Hsu
Chia-Pei Denise Hsu
Sharan RamaswamySharan Ramaswamy
Sharan Ramaswamy
Critical valve diseases in infants have a very poor prognosis for survival. Particularly challenging is for the valve replacement to support somatic growth. From a valve regenerative standpoint, bio-scaffolds have been extensively investigated recently. While bio-scaffold valves facilitate acute valve functionality, their xenogeneic properties eventually induce a hostile immune response. Our goal was to investigate if a bio-scaffold valve could be deposited with tissues derived from allogeneic stem cells, with a specific dynamic culture protocol to enhance the extracellular matrix (ECM) constituents, with subsequent stem cell removal. Porcine small intestinal submucosa (PSIS) tubular-shaped bio-scaffold valves were seeded with human bone marrow-derived mesenchymal stem cells (hBMMSCs), cultured statically for 8 days, and then exposed to oscillatory fluid-induced shear stresses for two weeks. The valves were then safely decellularized to remove the hBMMSCs while retaining their secreted ECM. This de novo ECM was found to include significantly higher (p < 0.05) levels of elastin compared to the ECM produced by the hBMMSCs under standard rotisserie culture. The elastin-rich valves consisted of ~8% elastin compared to the ~10% elastin composition of native heart valves. Allogeneic elastin promotes chemotaxis thereby accelerating regeneration and can support somatic growth by rapidly integrating with the host following implantation. As a proof-of-concept of accelerated regeneration, we found that valve interstitial cells (VICs) secreted significantly more (p < 0.05) collagen on the elastin-rich matrix compared to the raw PSIS bio-scaffold.