Ayman Mohammed Abd-Elhamed

Dr. Ayman Mohammed Abd-Elhamed

Faculty of Engineering, Helwan University, Cairo, Al Qāhirah, Egypt
+1
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2013 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
SMSayed Mahmoud
Sayed Mahmoud
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
RJRobert Jankowski
Robert Jankowski
The present paper investigates the coupled effect of the supporting soil flexibility and pounding between neighbouring, insufficiently separated equal height buildings under earthquake excitation. Two adjacent three-storey structures, modelled as inelastic lumped mass systems with different structural characteristics, have been considered in the study. The models have been excited using a suit of ground motions with different peak ground accelerations and recorded at different soil types. A nonlinear viscoelastic pounding force model has been employed in order to effectively capture impact forces during collisions. Spring-dashpot elements have been incorporated to simulate the horizontal and rotational movements of the supporting soil. The results of the numerical simulations, in the form of the structural nonlinear responses as well as the time-histories of energy dissipated during pounding-involved vibrations, are presented in the paper. In addition, the variation in storeys peak responses and peak dissipated energies for different gap sizes are also shown and comparisons are made with the results obtained for colliding buildings with fixed-base supports. Observations regarding the incorporation of the soil-structure interaction and its effect on the responses obtained are discussed. The results of the study indicate that the soil-structure interaction significantly influences the pounding-involved responses of equal height buildings during earthquakes, especially the response of the lighter and more flexible structure. It has been found that the soil flexibility decreases storey peak displacements, peak impact forces and peak energies dissipated during vibrations, whereas it usually leads to the increases in the peak accelerations at each storey level.

20 April 2018 in Buildings
Verified
Journal Article
Open access
PDF file
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
YSYasser Shaban
Yasser Shaban
SMSayed Mahmoud
Sayed Mahmoud
In this paper, logical analysis of data (LAD) is used to predict the seismic response of building structures employing the captured dynamic responses. In order to prepare the data, computational simulations using a single degree of freedom (SDOF) building model under different ground motion records are carried out. The selected excitation records are real and of different peak ground accelerations (PGA). The sensitivity of the seismic response in terms of displacements of floors to the variation in earthquake characteristics, such as soil class, characteristic period, and time step of records, peak ground displacement, and peak ground velocity, have also been considered. The dynamic equation of motion describing the building model and the applied earthquake load are presented and solved incrementally using the Runge-Kutta method. LAD then finds the characteristic patterns which lead to forecast the seismic response of building structures. The accuracy of LAD is compared to that of an artificial neural network (ANN), since the latter is the most known machine learning technique. Based on the conducted study, the proposed LAD model has been proven to be an efficient technique to learn, simulate, and blindly predict the dynamic response behaviour of building structures subjected to earthquake loads.

29 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
Soliman Abdulkarim AlkhatibSoliman Abdulkarim Alkhatib
Soliman Abdulkarim Alkhatib
Ahmed M. H. ABDELFATTAHAhmed M. H. ABDELFATTAH
Ahmed M. H. ABDELFATTAH
Terrorist bombing-induced casualties are not only related to immediate fatalities but also to structural deterioration, damage, or even collapse that might occur and may lead to tremendous loss of life. Efficient assessment of blast-induced structural damage following explosion events is becoming a growing problem in modern societies. An attempt based on machine learning is made in this study to anticipate structures’ responses and the associated structural damage to reinforced concrete (RC) buildings exposed to extremely short-duration explosive loads. A program is developed to generate a set of analytically derived data for nonlinear building models subjected to explosive loads. Common machine learning models and Python libraries were utilized during the development of our program implementation to learn from a dataset. The latter has different features or input parameters, such as the amount of explosive charge, the distance from the building, fundamental period, and the building’s mass and rigidity, as well as the soil type. Our database is thus used, along with our regression-and-classification based implementations, to generate an output index that estimates and categorizes the state of damage based on the several most-important parameters of the explosion exposure. In the input database, the state of damage, based on the values of captured damage indices, is classified into one of four cases. Our code efficiently predicts those cases using a model that learns from the database. The prediction rates of the presented model reach an overall high accuracy. Therefore, the proposed model provides an accurate prediction of the level of structural damage by using the computed damage indices.

4 November 2017 in Civil Engineering Journal
Verified
Journal Article
Open access
PDF file
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
SMSayed Mahmoud
Sayed Mahmoud
This paper aimed to investigate the seismic response of reinforced concrete (RC) frame buildings under linear and non-linear dynamic analysis. Different building models as bare frame and fully masonry infill frame have been developed for performing the analysis. In order to investigate the effect of irregular distributions of masonry infill walls in elevation on the seismic response behavior, an infill frame model with soft story has also been developed. The linear response spectrum (RS) dynamic analysis and the nonlinear time-history (TH) analysis methods are employed. Moreover, the induced energies in terms of input, potential and kinetic are also obtained from the TH analysis. Moreover, the interaction between infill walls and frames leads to considerable change in the induced responses comparable with the bare model.

11 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
SMSayed Mahmoud
Sayed Mahmoud
KAKhalid Saqer Alotaibi
Khalid Saqer Alotaibi
Most civil structures exhibit nonlinear behavior during moderate to severe earthquakes. Consequently, inelastic analysis is needed for seismic design. Several dynamic and static analysis methods are available for the assessment and design of engineering structures. Two of the available methods in terms of nonlinear dynamic time history analysis and nonlinear static analysis, which is known as pushover analysis, are employed herein to comprehensively study and investigate the seismic performance of multi-story building structures with different floor systems. Moreover, the study is extended to assess the actual values of the response reduction/modification factor (R-factor) for each building model, then evaluate the values with the code-recommended design values. Three-dimensional finite element building models with 5, 10 and 15 stories are developed for the evaluation process. The advanced computer program ETABS is used for developing and analyzing the buildings considering material and geometrical nonlinearity. A suit of seven earthquake records is considered and scaled according to the ASCE-16 seismic design code to excite the building models. The obtained results evidently reveal that the type of floor slab significantly impacts the seismic response of the building. More specifically, the effects of floor slabs on seismic demands are more evident in low- and mid-rise buildings. In addition, the type of slab system and height of the building have more influence on the response modification factors, especially for low-rise building models.

26 August 2024 in Journal of Low Frequency Noise, Vibration and Active Control
Verified
Journal Article
Open access
Ayman Mohammed Abd-ElhamedAyman Mohammed Abd-Elhamed
Ayman Mohammed Abd-Elhamed
SMSayed Mahmoud
Sayed Mahmoud
This study aims to primarily assess the dynamic behavior of ground-supported cylindrical tanks to real near-fault earthquake records with different frequency contents including soil-structure interaction effects. A cylindrical tank’s fluid-tank-soil interaction is modeled using a three-degree-of-freedom lumped mass model for the fluid. A mass-spring-dashpot model with frequency independence is used to model the soil/foundation system. Broad, medium, and slender tank models are developed considering and ignoring the soil flexibility effect. An algorithm based on discrete-time state-space approaches is developed for performing numerical simulations of the modeled tanks excited by the low-, medium-, and high-frequency contents. The obtained results for the modeled tanks in terms of base shear, overturning moment, and connective and impulsive mass displacements incorporating the influence of supporting soils as well as the frequency contents of excitation records are evaluated and compared with the corresponding results for modeled tanks with a fixed base. In addition, the liquid sloshing height for all aspect ratios is also evaluated and compared. The study’s findings clearly indicate that records with low-frequency contents require significantly more seismically demanding than other records for the considered soil types. Remarkably, soil-tank interaction under earthquake motions substantially amplifies the induced response.