Bo Wang

Dr. Bo Wang

Pediatric Ophthalmology, Duke University Hospital, Durham, California, USA
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
LKLarry Kagemann
Larry Kagemann
Bo WangBo Wang
Bo Wang
GWGadi Wollstein
Gadi Wollstein
HIHiroshi Ishikawa
Hiroshi Ishikawa
JNJessica E. Nevins
Jessica E. Nevins
JSJoel S Schuman
Joel S Schuman
Purpose. Previously, we demonstrated reduced Schlemm's canal cross-sectional area (SC-CSA) with increased perfusion pressure in a cadaveric flow model. The purpose of the present study was to determine the effect of acute IOP elevation on SC-CSA in living human eyes. Methods. The temporal limbus of 27 eyes of 14 healthy subjects (10 male, 4 female, age 36 ± 13 years) was imaged by spectral-domain optical coherence tomography at baseline and with IOP elevation (ophthalmodynamometer set at 30-g force). Intraocular pressure was measured at baseline and with IOP elevation by Goldmann applanation tonometry. Vascular landmarks were used to identify corresponding locations in baseline and IOP elevation scan volumes. Schlemm's canal CSA at five locations within a 1-mm length of SC was measured in ImageJ as described previously. A linear mixed-effects model quantified the effect of IOP elevation on SC-CSA. Results. The mean IOP increase was 189%, and the mean SC-CSA decrease was 32% (P < 0.001). The estimate (95% confidence interval) for SC-CSA response to IOP change was −66.6 (−80.6 to −52.7) μm2/mm Hg. Conclusions. Acute IOP elevation significantly reduces SC-CSA in healthy eyes. Acute dynamic response to IOP elevation may be a useful future characterization of ocular health in the management of glaucoma.

11 August 2016 in Scientific Reports
Verified
Journal Article
Open access
MMMatthew C. Murphy
Matthew C. Murphy
ICIan P. Conner
Ian P. Conner
CTCindy Y. Teng
Cindy Y. Teng
JLJesse D. Lawrence
Jesse D. Lawrence
ZSZaid Safiullah
Zaid Safiullah
KCKevin C. Chan
Kevin C. Chan
Glaucoma is the second leading cause of blindness worldwide and its pathogenesis remains unclear. In this study, we measured the structure, metabolism and function of the visual system by optical coherence tomography and multi-modal magnetic resonance imaging in healthy subjects and glaucoma patients with different degrees of vision loss. We found that inner retinal layer thinning, optic nerve cupping and reduced visual cortex activity occurred before patients showed visual field impairment. The primary visual cortex also exhibited more severe functional deficits than higher-order visual brain areas in glaucoma. Within the visual cortex, choline metabolism was perturbed along with increasing disease severity in the eye, optic radiation and visual field. In summary, this study showed evidence that glaucoma deterioration is already present in the eye and the brain before substantial vision loss can be detected clinically using current testing methods. In addition, cortical cholinergic abnormalities are involved during trans-neuronal degeneration and can be detected non-invasively in glaucoma. The current results can be of impact for identifying early glaucoma mechanisms, detecting and monitoring pathophysiological events and eye-brain-behavior relationships, and guiding vision preservation strategies in the visual system, which may help reduce the burden of this irreversible but preventable neurodegenerative disease.

1 March 2017 in Progress in Retinal and Eye Research
Verified
Journal Article
Closed access
ZDZachary M. Dong
Zachary M. Dong
GWGadi Wollstein
Gadi Wollstein
Bo WangBo Wang
Bo Wang
JSJoel S Schuman
Joel S Schuman

24 October 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
ZNZach Nadler
Zach Nadler
Bo WangBo Wang
Bo Wang
GWGadi Wollstein
Gadi Wollstein
JNJessica E. Nevins
Jessica E. Nevins
HIHiroshi Ishikawa
Hiroshi Ishikawa
JSJoel S Schuman
Joel S Schuman
We demonstrate an automated segmentation method for in-vivo 3D optical coherence tomography (OCT) imaging of the lamina cribrosa (LC). Manual segmentations of coronal slices of the LC were used as a gold standard in parameter selection and evaluation of the automated technique. The method was validated using two prototype OCT devices; each had a subject cohort including both healthy and glaucomatous eyes. Automated segmentation of in-vivo 3D LC OCT microstructure performed comparably to manual segmentation and is useful for investigative research and in clinical quantification of the LC.

1 August 2012 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
AFAndrew W. Francis
Andrew W. Francis
LKLarry Kagemann
Larry Kagemann
GWGadi Wollstein
Gadi Wollstein
HIHiroshi Ishikawa
Hiroshi Ishikawa
SFSteven Folz
Steven Folz
JSJoel S Schuman
Joel S Schuman
Purpose.: To describe morphometric details of the human aqueous humor (AH) outflow microvasculature visualized with 360-degree virtual castings during active AH outflow in cadaver eyes and to compare these structures with corrosion casting studies. Methods.: The conventional AH outflow pathways of donor eyes (n = 7) and eyes in vivo (n = 3) were imaged with spectral-domain optical coherence tomography (SD-OCT) and wide-bandwidth superluminescent diode array during active AH outflow. Digital image contrast was adjusted to isolate AH microvasculature, and images were viewed in a 3D viewer. Additional eyes (n = 3) were perfused with mock AH containing fluorescent tracer microspheres to compare microvasculature patterns. Results.: Observations revealed components of the conventional outflow pathway from Schlemm's canal (SC) to the superficial intrascleral venous plexus (ISVP). The superficial ISVP in both our study and corrosion casts were composed of interconnected venules (10–50 μm) forming a hexagonal meshwork. Larger radial arcades (50–100 μm) drained the region nearest SC and converged with larger tortuous vessels (>100 μm). A 360-degree virtual casting closely approximated corrosion casting studies. Tracer studies corroborated our findings. Tracer decorated several larger vessels (50–100 μm) extending posteriorly from the limbus in both raw and contrast-enhanced fluorescence images. Smaller tracer-labeled vessels (30–40 μm) were seen branching between larger vessels and exhibited a similar hexagonal network pattern. Conclusions.: SD-OCT is capable of detailed morphometric analysis of the conventional outflow pathway in vivo or ex vivo with details comparable to corrosion casting techniques.

21 November 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Bo WangBo Wang
Bo Wang
HTHuong Tran
Huong Tran
MSMatthew A Smith
Matthew A Smith
TKTigran Kostanyan
Tigran Kostanyan
SSSamantha E Schmitt
Samantha E Schmitt
GWGadi Wollstein
Gadi Wollstein
There is increasing clinical evidence that the eye is not only affected by intraocular pressure (IOP), but also by intracranial pressure (ICP). Both pressures meet at the optic nerve head of the eye, specifically the lamina cribrosa (LC). The LC is a collagenous meshwork through which all retinal ganglion cell axons pass on their way to the brain. Distortion of the LC causes a biological cascade leading to neuropathy and impaired vision in situations such as glaucoma and idiopathic intracranial hypertension. While the effect of IOP on the LC has been studied extensively, the coupled effects of IOP and ICP on the LC remain poorly understood. We investigated in-vivo the effects of IOP and ICP, controlled via cannulation of the eye and lateral ventricle in the brain, on the LC microstructure of anesthetized rhesus monkeys eyes using the Bioptigen spectral-domain optical coherence tomography (OCT) device (Research Triangle, NC). The animals were imaged with their head upright and the rest of their body lying prone on a surgical table. The LC was imaged at a variety of IOP/ICP combinations, and microstructural parameters, such as the thickness of the LC collagenous beams and diameter of the pores were analyzed. LC microstructure was confirmed by histology. We determined that LC microstructure deformed in response to both IOP and ICP changes, with significant interaction between the two. These findings emphasize the importance of considering both IOP and ICP when assessing optic nerve health.