Bassel Diban

Mr. Bassel Diban

University of Bologna
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2020 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Bassel DibanBassel Diban
Bassel Diban
GMG. Mazzanti
G. Mazzanti
This paper investigates the effect of temperature and stress coefficients of electrical conductivity of the insulation material on the life and reliability of HVDC extruded cables subjected to type test load cycles according to CIGRÉ Technical Brochure 496. The investigation is done by refining a procedure for the estimation of cable insulation life and reliability in the presence of load cycles, developed and implemented in a previous stage of this research, but applied so far to prequalification test load cycles only. Electric field is calculated using both the rigorous approach based on Maxwell's equations for transient electric field computation (exact method) and the closed-form steady-state Eoll's formula often employed in the preliminary design of DC cable insulation (approximated method). This enables also to assess the accuracy of the overall approximation involved by Eoll's formula in the case of type test conditions.

5 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Giovanni MazzantiGiovanni Mazzanti
Giovanni Mazzanti
Bassel DibanBassel Diban
Bassel Diban
Extensive simulations have been carried out so far of transient voltages superimposed onto the DC voltage of HVDC cable transmission systems. With the advent of VSC HVDC cable systems, attention has turned to long Temporary Over-voltages in such systems. Preliminary experiments on the possible adverse effects of these long TOVs on the insulation of VSC HVDC cables have started, but no simulation models for estimating their effect on cable life and reliability have been developed yet. This investigation fills this gap by carrying out the simulative evaluation of the life lost by HVDC extruded cables subjected to long TOVs (Part 1) and switching impulses applied during Type Tests (Part 2), so as to compare the severity of these two transient voltages superimposed onto the DC voltage of HVDC extruded cables. This Part 1-paper is focused on estimating the severity of TOVs on extruded cable insulation by: calculating the electric field during the TOV; comparing it with the field during Type Test load cycles; using Miner's law of cumulated damage to calculate the life lost during the TOV, thereby also locating the most severely stressed point of insulation. In Part 2-paper, a similar evaluation for switching impulses and an overall comparison are performed.

21 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Bassel DibanBassel Diban
Bassel Diban
Giovanni MazzantiGiovanni Mazzanti
Giovanni Mazzanti
This paper aims at studying the effect of cable characteristics on the thermal instability of 320 kV and 500 kV Cross-Linked Polyethylene XLPE-insulated high voltage direct-current (HVDC) cables buried in soil for different values of the applied voltages, by the means of sensitivity analysis of the insulation losses to the electrical conductivity coefficients of temperature and electric field, a and b. It also finds the value of dielectric loss coefficient βd for DC cables, which allows an analytical calculation of the temperature rise as a function of insulation losses and thermal resistances. A Matlab code is used to iteratively solve Maxwell’s equations and find the electric field distribution, the insulation losses and the temperature rise inside the insulation due to insulation losses of the cable subjected to load cycles according to CIGRÉ Technical Brochure 496. Thermal stability diagrams are found to study the thermal instability and its relationship with the cable ampacity. The results show high dependency of the thermal stability on the electrical conductivity of cable insulating material, as expressed via the conductivity coefficients of temperature and electric field. The effect of insulation thickness on both the insulation losses and the thermal stability is also investigated.

5 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Giovanni MazzantiGiovanni Mazzanti
Giovanni Mazzanti
Bassel DibanBassel Diban
Bassel Diban
In a previous paper (Part 1) the authors have performed the simulative evaluation of the life lost by HVDC extruded cables subjected to long TOVs occurring in VSC HVDC cable systems. The conclusions were that it cannot be completely ruled out that the field levels and the duration of such TOVs are a potential threat to certain cable designs, and tests other than Load Cycling Type Tests after CIGRÉ Technical Brochure 496 could assess quantitatively the potential threat associated with long TOVs. For these reasons, in this Part 2 superimposed switching impulses applied during Type Tests after TB 496 are analyzed in order to check if such impulses might be equivalent to long TOVs as for their electro-thermal stress effects on extruded insulation. The analysis is similar to that carried out for long TOVs in Part 1, i.e., it consists of: calculating the electric field during superimposed switching impulses; comparing it with the field during long TOVs; calculating with Miner's law of cumulated damage the life lost during superimposed switching impulses and comparing it with the loss of life during TOVs. A brief literature survey of potential high field effects during long TOVs is also reported.

20 April 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Bassel DibanBassel Diban
Bassel Diban
Giovanni MazzantiGiovanni Mazzanti
Giovanni Mazzanti
PSPaolo Seri
Paolo Seri
This study, in two parts, investigates the cable design of HVDC cables depending on life modelling of the insulating material. This paper is the first part, in which a parametric analysis is carried out, illustrating the way in which different parameters affect the life-based feasible designs of an HVDC cable with known nominal voltage and ampacity. An ad hoc Matlab code has been developed for this study. Results show great sensitivity of the lifetime to insulation geometry, as a slight variation in inner and outer insulation radii leads to a significant variation of cable life due mainly to the related electric field variation. The effect of temperature can be hardly observed in the life map due to the predominant effect of electric field. Increasing the maximum conductor temperature may not necessarily extend the feasible design area, which is also limited by the maximum temperature drop across insulation thickness. The higher the applied voltage, the greater the cable dimensions. This study also emphasizes the need to keep a low enough value of soil thermal resistivity, which considerably reduces the cable dimensions. Temperature coefficient of conductivity shows a nonlinear (mainly drastic) effect on the life. On the contrary, Field coefficient of conductivity shows a slight positive effect on the life. Part 2 of this study will investigate the effect of electrical and thermal transients on the life-based geometric design of HVDC cables.

10 October 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Bassel DibanBassel Diban
Bassel Diban
Giovanni MazzantiGiovanni Mazzanti
Giovanni Mazzanti
PSPaolo Seri
Paolo Seri
This study, in two parts, investigates the design of high-voltage direct-current (HVdc) cables depending on electrothermal life modeling of the insulating material. The first part investigated the way in which different parameters affect the design of an HVdc cable in steady-state conditions, i.e., with known nominal voltage and ampacity. This article investigates the effect of electrical (i.e., voltage) transients, such as voltage polarity reversals (VPRs), in addition to thermal transients (such as load cycles of cable current) on the electrothermal life map of HVdc cables, and their influence on cable feasibility. An ad hoc MATLAB code has been developed for this study. The results show a considerable negative effect of electrical transients on the expected life. A more severe effect of electrical transients is noticed for materials with a lower value of the temperature coefficient of conductivity, due to a longer duration of transients. On the contrary, thermal transients associated with load cycles—which mostly imply current values equal to or lower than cable ampacity—imply insulation temperature values always lower than the maximum permissible temperature, and thus, they have a positive effect on the electrothermal life since the thermal stress applied on the cable insulation will be reduced, allowing for smaller cable geometries for a fixed voltage and ampacity rating. It must be noticed that only the electrothermal life is investigated in this article, and other types of stresses (e.g., mechanical stress) may also affect insulation life, but this is out of the scope of this study.