The Study of Health in Pomerania (SHIP), a population-based study from a rural state in northeastern Germany with a relatively poor life expectancy, supplemented its comprehensive examination program in 2008 with whole-body MR imaging at 1.5 T (SHIP-MR). We reviewed more than 100 publications that used the SHIP-MR data and analyzed which sequences already produced fruitful scientific outputs and which manuscripts have been referenced frequently. Upon reviewing the publications about imaging sequences, those that used T1-weighted structured imaging of the brain and a gradient-echo sequence for R2* mapping obtained the highest scientific output; regarding specific body parts examined, most scientific publications focused on MR sequences involving the brain and the (upper) abdomen. We conclude that population-based MR imaging in cohort studies should define more precise goals when allocating imaging time. In addition, quality control measures might include recording the number and impact of published work, preferably on a bi-annual basis and starting 2 years after initiation of the study. Structured teaching courses may enhance the desired output in areas that appear underrepresented.
To compare the accuracy of a semi-quantitative proton resonance frequency shift (PRFS) thermal mapping interface and an alternative qualitative T1 thermometry model in predicting tissue necrosis in an established routine setting of MRI-guided laser ablation in the human liver. 34 cases of PRFS-guided (GRE) laser ablation were retrospectively matched with 34 cases from an earlier patient population of 73 individuals being monitored through T1 magnitude image evaluation (FLASH 2D). The model-specific real-time estimation of necrotizing thermal impact (above 54 °C zone and T1 signal loss, respectively) was correlated in size with the resulting necrosis as shown by lack of enhancement on the first-day contrast exam (T1). Matched groups were compared using the Mann-Whitney test. Online PRFS guidance was available in 33 of 34 cases. Positive size correlation between calculated impact zone and contrast defect at first day was evident in both groups (p < 0.0004). The predictive error estimating necrosis was median 21 % (range 1 % - 52 %) in the PRFS group and 61 % (range 22 - 84 %) in the T1 magnitude group. Differences in estimating lethal impact were significant (p = 0.004), whereas the real extent of therapy-induced necrosis showed no significant difference (p > 0.28) between the two groups. PRFS thermometry is feasible in a clinical setting of thermal hepatic tumor ablation. As an interference-free MR-tool for online therapy monitoring its accuracy to predict tissue necrosis is superior to a competing model of thermally induced alteration of the T1 magnitude signal.
To evaluate the potency of Gd-EOB-DTPA to support hepatic catheter placement in laser ablation procedures by quantifying time-dependent delineation effects for instrumentation and target tumor within liver parenchyma. Monitoring potential influence on online MR thermometry during the ablation procedure is a secondary aim. 30 cases of MR-guided laser ablation were performed after i.v. bolus injection of gadoxetic acid (0.025 mmol/Kg Gd-EOB-DTPA; Bayer Healthcare, Berlin, Germany). T1-weighted GRE sequences were used for applicator guidance (FLASH 3D) in the catheter placement phase and for therapy monitoring (FLASH 2D) in the therapy phase. SNR and consecutive CNR values were measured for elements of interest plotted over time both for catheter placement and therapy phase and compared with a non-contrast control group of 19 earlier cases. Statistical analysis was realized using the paired Wilcoxon test. Sustainable signal elevation of liver parenchyma in the contrast-enhanced group was sufficient to silhouette both target tumor and applicator against the liver. Differences in time dependent CNR alteration were highly significant between contrast-enhanced and non-contrast interventions for parenchyma and target on the one hand (p = 0.020) and parenchyma and instrument on the other hand (p = 0.002). Effects lasted for the whole procedure (monitoring up to 60 min) and were specific for the contrast-enhanced group. Contrasting maxima were seen after median 30 (applicator) and 38 (tumor) minutes, in the potential core time of a multineedle procedure. Contrast influence on T1 thermometry for real-time monitoring of thermal impact was not significant (p = 0.068–0.715). Results strongly support anticipated promotive effects of Gd-EOB-DTPA for MR-guided percutaneous liver interventions by proving and quantifying the delineating effects for therapy-relevant elements in the procedure. Time benefit, cost effectiveness and oncologic outcome of the described beneficiary effects will have to be part of further investigations.
(1) Background: We aimed to compare the accuracy of after-hours CT reports created in a traditional in-house setting versus a teleradiology setting by assessing the discrepancy rates between preliminary and final reports. (2) Methods: We conducted a prospective study to determine the number and severity of discrepancies between preliminary and final reports for 7761 consecutive after-hours CT scans collected over a 21-month period. CT exams were performed during on-call hours and were proofread by an attending the next day. Discrepancies between preliminary and gold-standard reports were evaluated by two senior attending radiologists, and differences in rates were assessed for statistical significance. (3) Results: A total of 7209 reports were included in the analysis. Discrepancies occurred in 1215/7209 cases (17%). Among these, 433/7209 reports (6%) showed clinically important differences between the preliminary and final reports. A total of 335/5509 of them were in-house reports (6.1%), and 98/1700 were teleradiology reports (5.8%). The relative frequencies of report changes were not significantly higher in teleradiology. (4) Conclusions: The accuracy of teleradiology reports was not inferior to that of in-house reports, with very similar clinically important differences rates found in both reporting situations.