ChengYing Chung

Prof. Dr. ChengYing Chung

Mechanical and Electromechanical Engineering, National Ilan University, Yilan, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ChengYing ChungChengYing Chung
ChengYing Chung
YCYu-Wei Cheng
Yu-Wei Cheng
CLChing-Hsing Luo
Ching-Hsing Luo

1 December 2016 in European Journal of Integrative Medicine
Verified
Journal Article
Closed access
CLChing-Hsing Luo
Ching-Hsing Luo
CSChun-Jen Su
Chun-Jen Su
THTing-Yi Huang
Ting-Yi Huang
ChengYing ChungChengYing Chung
ChengYing Chung

20 May 2006 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ChengYing ChungChengYing Chung
ChengYing Chung
KCKeng-Chi Cho
Keng-Chi Cho
CCChih-Chiang Chang
Chih-Chiang Chang
CLCheng-Hsiang Lin
Cheng-Hsiang Lin
WYWei-Chung Yen
Wei-Chung Yen
SCShean-Jen Chen
Shean-Jen Chen
We develop an adaptive-optics system based on a Mach–Zehnder radial shearing interferometer with liquid-crystal-device (LCD) phase-shift interferometry (PSI). Using accurate phase calibration and transient nematic driving of the LCD, the developed three-step PSI procedure can be achieved in a time of 5  ms. The proposed Mach–Zehnder radial shearing PSI method reconstructs the phase information using a digital signal processor (DSP). The DSP then computes appropriate control signals to drive a deformable mirror in such a way as to eliminate the wavefront distortion. The current adaptive-optics system is capable of suppressing low-frequency thermal disturbances with a signal-to-noise ratio improvement of more than 20  dB and a steady-state phase error of less than 0.02π root mean square when the control loop is operated at a frequency of 30  Hz.

1 December 2016 in European Journal of Integrative Medicine
Verified
Journal Article
Closed access
CLChing-Hsing Luo
Ching-Hsing Luo
ChengYing ChungChengYing Chung
ChengYing Chung

1 March 2013
Verified
Conference Paper
Closed access
ChengYing ChungChengYing Chung
ChengYing Chung
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
YCYu-Wen Chu
Yu-Wen Chu
CLChing-Hsing Luo
Ching-Hsing Luo
Pulse diagnosis is an important diagnostic method in traditional Chinese medicine. However, it lacks objectivity. To standardize pulse diagnosis, pulse-taking platforms are required. This study implements a complete processing method for wrist pulse signals obtained from a pulse diagnosis instrument with a two-dimensional pressure sensor array to extract the spatial features. First, a zero-phase filter is adopted for acquiring the appropriate frequency band for bio-signals and removing noise. The filter is better to extract the pulse trend due to no phase shift distortion. Next, irregular pulses are removed prior to signal analysis. Then, percussion peaks are identified and the interval between them is used to calculate the pulse rate. Finally, a polynomial surface fitting method is used to compute pulse features, such as the peak, length, width, and surface curvature, from a visualized pulse, which is helpful for the study of pulse classification or even pulse diagnosis.

1 March 2013
Verified
Conference Paper
Closed access
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
YCYu-Wen Chu
Yu-Wen Chu
ChengYing ChungChengYing Chung
ChengYing Chung
CHChung-Shing Hu
Chung-Shing Hu
CLChing-Hsing Luo
Ching-Hsing Luo
CYCheng-Chang Yeh
Cheng-Chang Yeh
Clinical experiences of pulse diagnosis are possible to be quantified and get rid of the viewpoint of nonscientific and subjectivity. The aim of this report wants to propose a new vision of pulse conditions by version 2 of Bi-Sensing Pulse Diagnosis Instrument (BSPDI V2). BSPDI V2 can repeat the pulse taking depth of physicians by displacement detection system, and mimic the fingertip sensations by pulse detection system. The 3-Dimension Pulse Mapping (3DPM) of pulse conditions can be constructed by BSPDI V2. Hence, the new vision platform of pulse conditions is to be built through BSPDI V2. Therefore, pulse conditions can be stereoscopic observation based on spatial and temporal dimensions. The more information and clearer outline of pulse conditions are to be explored, and the quantification of pulse patterns will much closer to fingertip sensations of physicians.