Justin Yu-Feng Chung

Prof. Justin Yu-Feng Chung

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CHChung-Shing Hu
Chung-Shing Hu
CYCheng-Chang Yeh
Cheng-Chang Yeh
CLChing-Hsing Luo
Ching-Hsing Luo

1 September 2012 in European Journal of Integrative Medicine
Verified
Journal Article
Closed access
CLChing-Hsing Luo
Ching-Hsing Luo
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CHChung-Shing Hu
Chung-Shing Hu
CYCheng-Chang Yeh
Cheng-Chang Yeh
XSXiao-Chen Si
Xiao-Chen Si
CLChi-Hsien Liang
Chi-Hsien Liang

1 January 2012 in Evidence-Based Complementary and Alternative Medicine
Verified
Journal Article
Open access
PDF file
CHChung-Shing Hu
Chung-Shing Hu
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CYCheng-Chang Yeh
Cheng-Chang Yeh
CLChing-Hsing Luo
Ching-Hsing Luo
Conventionally, a pulse taking platform is based on a single sensor, which initiates a feasible method of quantitative pulse diagnosis. The aim of this paper is to implement a pulse taking platform with a tactile array sensor. Three-dimensional wrist pulse signals are constructed, and the length, width, ascending slope, and descending slope are defined following the surface of the wrist pulse. And the pressure waveform of the wrist pulse obtained through proposed pulse-taking platform has the same performance as the single sensor. Finally, the results of a paired samplest-test reveal that the repeatability of the proposal platform is consistent with clinical experience. On the other hand, the results of ANOVA indicate that differences exist among different pulse taking depths, and this result is consistent with clinical experience in traditional Chinese medicine pulse diagnosis (TCMPD). Hence, the proposed pulse taking platform with an array sensor is feasible for quantification in TCMPD.

1 October 2014 in European Journal of Integrative Medicine
Verified
Journal Article
Closed access
YCYu-Wen Chu
Yu-Wen Chu
CLChing-Hsing Luo
Ching-Hsing Luo
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CHChung-Shing Hu
Chung-Shing Hu
CYCheng-Chang Yeh
Cheng-Chang Yeh

1 September 2012 in European Journal of Integrative Medicine
Verified
Journal Article
Closed access
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CHChung-Shing Hu
Chung-Shing Hu
CLChing-Hsing Luo
Ching-Hsing Luo
CYCheng-Chang Yeh
Cheng-Chang Yeh
XSXiao-Chen Si
Xiao-Chen Si
CLChi-Hsien Liang
Chi-Hsien Liang

1 October 2012 in The Journal of Alternative and Complementary Medicine
Verified
Journal Article
Open access
CLChing-Hsing Luo
Ching-Hsing Luo
Justin Yu-Feng ChungJustin Yu-Feng Chung
Justin Yu-Feng Chung
CYCheng-Chang Yeh
Cheng-Chang Yeh
XSXiao-Chen Si
Xiao-Chen Si
CCChien-Chen Chang
Chien-Chen Chang
YCYu-Wen Chu
Yu-Wen Chu
Background: A stringlike pulse is highly related to hypertension, and many classification approaches have been proposed in which the differentiation pulse wave (dPW) can effectively classify the stringlike pulse indicating hypertension. Unfortunately, the dPW method cannot distinguish the spring stringlike pulse from the stringlike pulse so labeled by physicians in clinics. Design: By using a Bi-Sensing Pulse Diagnosis Instrument (BSPDI), this study proposed a novel Plain Pulse Wave (PPW) to classify a stringlike pulse based on an array of pulse signals, mimicking a Traditional Chinese Medicine physician's finger-reading skill. Results: In comparison to PPWs at different pulse taking positions, phase delay Δθand correlation coefficient r can be elucidated as the quantification parameters of stringlike pulse. As a result, the recognition rates of a hypertensive stringlike pulse, spring stringlike pulse, and non–stringlike pulse are 100%, 100%, 77% for PPW and 70%, 0%, 59% for dPW, respectively. Conclusions: Integrating dPW and PPW can unify the classification of stringlike pulse including hypertensive stringlike pulse and spring stringlike pulse. Hence, the proposed novel method, PPW, enhances quantification of stringlike pulse.