Constantin Ε. Chalioris

Prof. Dr. Constantin Ε. Chalioris

DEMOCRITUS UNIVERSITY OF THRACE, School of Engineering, Department of Civil Engineering, Division of Structural Engineering, Laboratory of Reinforced Concrete and Seismic Design of Structures
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2007 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Closed access
PDF file
CKChris G. Karayannis
Chris G. Karayannis
Constantin Ε. ChaliorisConstantin Ε. Chalioris
Constantin Ε. Chalioris
GSGeorge M. Sirkelis
George M. Sirkelis


1 May 2009 in Cement and Concrete Composites
Verified
Journal Article
Closed access
Constantin Ε. ChaliorisConstantin Ε. Chalioris
Constantin Ε. Chalioris
CKChris G. Karayannis
Chris G. Karayannis

1 February 2016 in Construction and Building Materials
Verified
Journal Article
Closed access
CKChris G. Karayannis
Chris G. Karayannis
Constantin Ε. ChaliorisConstantin Ε. Chalioris
Constantin Ε. Chalioris
GAGeorgia M. Angeli
Georgia M. Angeli
NPNikos A. Papadopoulos
Nikos A. Papadopoulos
MFMaria J. Favvata
Maria J. Favvata
CPCostas P. Providakis
Costas P. Providakis

29 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
Constantin Ε. ChaliorisConstantin Ε. Chalioris
Constantin Ε. Chalioris
PKParthena Maria Kosmidou
Parthena Maria Kosmidou
Christos G. KarayannisChristos G. Karayannis
Christos G. Karayannis
Reinforced concrete (RC) beams under cyclic loading usually suffer from reduced aggregate interlock and eventually weakened concrete compression zone due to severe cracking and the brittle nature of compressive failure. On the other hand, the addition of steel fibers can reduce and delay cracking and increase the flexural/shear capacity and the ductility of RC beams. The influence of steel fibers on the response of RC beams with conventional steel reinforcements subjected to reversal loading by a four-point bending scheme was experimentally investigated. Three slender beams, each 2.5 m long with a rectangular cross-section, were constructed and tested for the purposes of this investigation; two beams using steel fibrous reinforced concrete and one with plain reinforced concrete as the reference specimen. Hook-ended steel fibers, each with a length-to-diameter ratio equal to 44 and two different volumetric proportions (1% and 3%), were added to the steel fiber reinforced concrete (SFRC) beams. Accompanying, compression, and splitting tests were also carried out to evaluate the compressive and tensile splitting strength of the used fibrous concrete mixtures. Test results concerning the hysteretic response based on the energy dissipation capabilities (also in terms of equivalent viscous damping), the damage indices, the cracking performance, and the failure of the examined beams were presented and discussed. Test results indicated that the SFRC beam demonstrated improved overall hysteretic response, increased absorbed energy capacities, enhanced cracking patterns, and altered failure character from concrete crushing to a ductile flexural one compared to the RC beam. The non-fibrous reference specimen demonstrated shear diagonal cracking failing in a brittle manner, whereas the SFRC beam with 1% steel fibers failed after concrete spalling with satisfactory ductility. The SFRC beam with 3% steel fibers exhibited an improved cyclic response, achieving a pronounced flexural behavior with significant ductility due to the ability of the fibers to transfer the developed tensile stresses across crack surfaces, preventing inclined shear cracks or concrete spalling. A report of an experimental database consisting of 39 beam specimens tested under cyclic loading was also presented in order to establish the effectiveness of steel fibers, examine the fiber content efficiency and clarify their role on the hysteretic response and the failure mode of RC structural members.

25 July 2018 in Fibers
Verified
Journal Article
Open access
PDF file
Constantin Ε. ChaliorisConstantin Ε. Chalioris
Constantin Ε. Chalioris
PKParthena Maria Kosmidou
Parthena Maria Kosmidou
NPNikos A. Papadopoulos
Nikos A. Papadopoulos
The effectiveness of a new retrofitting technique to upgrade the structural behaviour of reinforced concrete (RC) deep beams without steel stirrups using carbon fibre-reinforced polymer (CFRP) ropes as the only transverse shear reinforcement is experimentally investigated. Five shear-critical beams with rectangular and T-shaped cross-section are tested under monotonic loading. The strengthening schemes include (a) one vertical and one diagonal single-link CFRP rope that are internally applied through the web of the rectangular beam using an embedded through-section (ETS) system and (b) two vertical U-shaped double-link ropes that are applied around the perimeter of the web of the flanged beam using a near-surface-mounted (NSM) system. In both cases, the free lengths of the CFRP ropes have been properly anchored using epoxy bonded lap splices of the rope as NSM at (a) the top and the bottom of the web of the rectangular beam and (b) the top of the slab of the T-beam. Promising results have been derived, since the proposed strengthening technique enhanced the strength and altered the brittle shear failure to a ductile flexural one. The experimental results of this study were also used to check the validity of an analytical approach to predict the strength of shear strengthened deep beams using FRP ropes as transverse link reinforcement.