Chelsea Harrington

Ms. Chelsea Harrington

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HSHong Sun
Hong Sun
CHChelsea Harrington
Chelsea Harrington
NGNancy Gerloff
Nancy Gerloff
MMMark Mandelbaum
Mark Mandelbaum
SJStacey Jeffries-Miles
Stacey Jeffries-Miles
EVEverardo Vega
Everardo Vega
Surveillance and detection of polioviruses (PV) remain crucial to monitoring eradication progress. Intratypic differentiation (ITD) using the real-time RT-PCR kit is key to the surveillance workflow, where viruses are screened after cell culture isolation before a subset are verified by sequencing. The ITD kit is a series of real-time RT-PCR assays that screens cytopathic effect (CPE)-positive cell cultures using the standard WHO method for virus isolation. Because ITD screening is a critical procedure in the poliovirus identification workflow, validation of performance of real-time PCR platforms is a core requirement for the detection of poliovirus using the ITD kit. In addition, the continual update and improvement of the ITD assays to simplify interpretation in all platforms is necessary to ensure that all real-time machines are capable of detecting positive real-time signals. Four platforms (ABI7500 real-time systems, Bio-Rad CFX96, Stratagene MX3000P, and the Qiagen Rotor-Gene Q) were validated with the ITD kit and a redesigned poliovirus probe. The poliovirus probe in the real-time RT-PCR pan-poliovirus (PanPV) assay was re-designed with a double-quencher (Zen™) to reduce background fluorescence and potential false negatives. The updated PanPV probe was evaluated with a panel consisting of 184 polioviruses and non-polio enteroviruses. To further validate the updated PanPV probe, the new assay was pilot tested in five Global Polio Laboratory Network (GPLN) laboratories (Madagascar, India, Philippines, Pakistan, and Democratic Republic of Congo). The updated PanPV probe performance was shown to reduce background fluorescence and decrease the number of false positives compared to the standard PanPV probe.

22 December 2021 in Microbiology Spectrum
Verified
Journal Article
Closed access
CHChelsea Harrington
Chelsea Harrington
HSHong Sun
Hong Sun
SJStacey Jeffries-Miles
Stacey Jeffries-Miles
NGNancy Gerloff
Nancy Gerloff
MMMark Mandelbaum
Mark Mandelbaum
EVEverardo Vega
Everardo Vega
The GPLN is a global surveillance system composed of 146 laboratories in 92 countries, in each of the six World Health Organization regions. Laboratory surveillance for PV relies on virus isolation by cell culture to identify PV in stool samples from AFP cases.

1 November 2021 in Journal of Virological Methods
Verified
Journal Article
Closed access
MHMichelle J. Honeywood
Michelle J. Honeywood
SJStacey Jeffries-Miles
Stacey Jeffries-Miles
KWKimberly Wong
Kimberly Wong
CHChelsea Harrington
Chelsea Harrington
CBCara C. Burns
Cara C. Burns
EVEverardo Vega
Everardo Vega

4 July 2022 in Frontiers in Environmental Science
Verified
Journal Article
Open access
HBHanen Belgasmi
Hanen Belgasmi
SMStacey Jeffries Miles
Stacey Jeffries Miles
LSLeanna Sayyad
Leanna Sayyad
KWKimberly Wong
Kimberly Wong
CHChelsea Harrington
Chelsea Harrington
EVEverardo Vega
Everardo Vega
Acute flaccid paralysis (AFP) surveillance has been used to identify polio cases and target vaccination campaigns since the inception of the Global Poliovirus Eradication Initiative (GPEI) in 1988. To date, only Afghanistan and Pakistan have failed to interrupt wild poliovirus transmission. Circulation of vaccine-derived polioviruses (VDPV) continues to be a problem in high-risk areas of the Eastern Mediterranean, African, and Southeast Asian regions. Environmental surveillance (ES) is an important adjunct to AFP surveillance, helping to identify circulating polioviruses in problematic areas. Stools from AFP cases and contacts (>200,000 specimens/year) and ES samples (>642 sites) are referred to 146 laboratories in the Global Polio Laboratory Network (GPLN) for testing. Although most World Health Organization supported laboratories use the two-phase separation method due to its simplicity and effectiveness, alternative simple, widely available, and cost-effective methods are needed. The CAFÉ (Concentration and Filtration Elution) method was developed from existing filtration methods to handle any type of sewage or residual waters. At $10–20 US per sample for consumable materials, CAFÉ is cost effective, and all equipment and reagents are readily available from markets and suppliers globally. The report describes the results from a parallel study of CAFÉ method with the standard two-phase separation method. The study was performed with samples collected from five countries (Guatemala, Haïti, Thailand, Papua New Guinea, and the Philippines), run in three laboratories–(United States, Thailand and in the Philippines) to account for regional and sample-to-sample variability. Samples from each site were divided into two 500 ml aliquots and processed by both methods, with no other additional concentration or manipulation. The results of 338 parallel-tested samples show that the CAFÉ method is more sensitive than the two-phase separation method for detection of non-polio enteroviruses (p-value < 0.0001) and performed as well as the two-phase separation method for polioviruses detection with no significant difference (p-value > 0.05). The CAFÉ method is a robust, sensitive, and cost-effective method for isolating enteroviruses from residual waters.

4 February 2025 in Microbiology Spectrum
Verified
Journal Article
Closed access
PMPaula L. Marcet
Paula L. Marcet
BSBrandon Short
Brandon Short
ADAshley Deas
Ashley Deas
HSHong Sun
Hong Sun
CHChelsea Harrington
Chelsea Harrington
NGNancy Gerloff
Nancy Gerloff
In the Global Polio Laboratory Network (GPLN), poliovirus (PV) screening results from acute flaccid paralysis (AFP) surveillance is based on virus isolation (VI) through cell culture, entailing long turnaround times and the amplification of live poliovirus. An alternative Direct Detection strategy (DD-ITD) for screening viral nucleic acid from stools, bypassing the need for virus culture, has been developed and extensively validated by GPLN partners. A multi-laboratory demonstration project was conceived to field-test the DD-ITD method by GPLN laboratories from the WHO African, Western Pacific, and Eastern Mediterranean regions, where wild serotype 1 or vaccine-derived polioviruses still circulate. Strategically selected laboratories were tasked to simultaneously process stool suspensions with the current gold-standard VI method and the new DD-ITD strategy. Results from 12 laboratories were compiled and analyzed to assess the quality of each RNA extraction and rRT-PCR run. Matched results for both methods of over 10,500 specimens showed an overall method agreement of 91%. All laboratories detected more PV presumptive positive samples with the DD-ITD strategy than with VI, but a large proportion of DD-ITD positive results (72%) were inconclusive or non-typeable, requiring confirmation through sequencing. A total of 298 (2.8%) samples were PV positive using both methods, 828 (7.9%) positive only for DD-ITD, and 62 (0.6%) positive only with VI. The DD-ITD overall performance, quality of results, and agreement between method results varied significantly across participating laboratories. DD-ITD implementation would entail building proficiency in advanced molecular laboratory techniques and data analysis, and increased demand for confirmatory sequencing. IMPORTANCE: Surveillance of acute flaccid paralysis (AFP) and sensitive poliovirus detection are key components of the WHO Global Polio Eradication Strategy. This work summarizes the results of a multi-laboratory evaluation designed to field-test the performance and applicability of a molecular Direct Detection strategy (DD-ITD) that does not require amplification of live poliovirus. AFP samples were processed in parallel with both the DD-ITD and the current gold-standard PV detection methodology, based on virus isolation (VI) through cell culture. All participating laboratories detected more PV presumptive positive samples using the DD-ITD strategy than with virus isolation methodology, although a higher proportion of DD-ITD results required confirmatory sequencing. Significant variability among laboratories was observed in the quality of the results and overall DD-ITD performance. Implementing DD-ITD would entail building proficiency in advanced molecular laboratory techniques and strengthening data analysis skills.

2 November 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NGNancy Gerloff
Nancy Gerloff
MMMark Mandelbaum
Mark Mandelbaum
HPHong Pang
Hong Pang
NCNikail Collins
Nikail Collins
BBBrittani Brown
Brittani Brown
EVEverardo Vega
Everardo Vega
Polioviruses are positive-sense, single-stranded RNA picornaviruses and the principal cause of poliomyelitis. Global poliovirus surveillance has relied on poliovirus isolation in cells, which may take a minimum of 10 days, involves maintaining two cell lines, and propagates virus in high titers. With eradication underway, a major objective of the Global Polio Eradication Initiative (GPEI) is to develop culture-independent detection of polioviruses as an alternative method to complement the current virus isolation technique. A culture-independent method on poliovirus-positive stool suspensions was assessed with commercially available recombinant soluble poliovirus receptor (PVR) coupled to Histidine (His) tags. Viral RNA was screened by quantitative real-time reverse transcription PCR using the poliovirus intratypic differentiation kit. Poliovirus recovery was optimized with PVR-His–tagged protein and buffers supplemented with polyethylene glycol. To validate the poliovirus-PVR–His tag purification assay, 182 poliovirus-positive stools of programmatic importance were parallel tested against the GPLN-accepted virus isolation method. The PVR-His tag enrichment method detected poliovirus in 164 of 171 poliovirus-positive stools, whereas the virus isolation method misidentified 38 stools as poliovirus-negative (McNemar χ2 p<0.0001). Using this method in combination with RNA extraction, viral RNA recovery increased and showed similar (WPV1) or higher (Sabin 1) sensitivity than the World Health Organization accredited variation of the virus isolation method. The PVR-His enrichment method could be a viable addition to poliovirus surveillance; similar methods have the potential to capture other human pathogens such as EV71 using an appropriate soluble His tag receptor.