Chen-Hsun Weng

Dr. Chen-Hsun Weng

Medical device innovation center, NCKU
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2007 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CWChen-Hsun Weng
Chen-Hsun Weng
WYW Yeh
W Yeh
KHK Ho
K Ho
GLGwo-Bin Lee
Gwo-Bin Lee

10 July 2010 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
CWChen-Hsun Weng
Chen-Hsun Weng
KLKang-Yi Lien
Kang-Yi Lien
SYSung-Yi Yang
Sung-Yi Yang
GLGwo-Bin Lee
Gwo-Bin Lee

11 July 2012 in Sensors
Verified
Journal Article
Open access
PDF file
CWChen-Hsun Weng
Chen-Hsun Weng
CHChao-Jyun Huang
Chao-Jyun Huang
GLGwo-Bin Lee
Gwo-Bin Lee
The use of microfluidic systems for screening of aptamers and their biomedical applications are reviewed in this paper. Aptamers with different nucleic acid sequences have been extensively studied and the results demonstrated a strong binding affinity to target molecules such that they can be used as promising candidate biomarkers for diagnosis and therapeutics. Recently, the aptamer screening protocol has been conducted with microfluidic-based devices. Furthermore, aptamer affinity screening by a microfluidic-based method has demonstrated remarkable advantages over competing traditional methods. In this paper, we first reviewed microfluidic systems which demonstrated efficient and rapid screening of a specific aptamer. Then, the clinical applications of screened aptamers, also performed by microfluidic systems, are further reviewed. These automated microfluidic systems can provide advantages over their conventional counterparts including more compactness, faster analysis, less sample/reagent consumption and automation. An aptamer-based compact microfluidic system for diagnosis may even lead to a point-of-care device. The use of microfluidic systems for aptamer screening and diagnosis is expected to continue growing in the near future and may make a substantial impact on biomedical applications.

28 August 2008 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
WLWen-Bin Lee
Wen-Bin Lee
CWChen-Hsun Weng
Chen-Hsun Weng
FCFong-Yu Cheng
Fong-Yu Cheng
CYChen-Sheng Yeh
Chen-Sheng Yeh
HLHuan-Yao Lei
Huan-Yao Lei
GLGwo-Bin Lee
Gwo-Bin Lee

28 January 2008 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
CWChen-Hsun Weng
Chen-Hsun Weng
CHChih-Chia Huang
Chih-Chia Huang
CYChen-Sheng Yeh
Chen-Sheng Yeh
HLHuan-Yao Lei
Huan-Yao Lei
GLGwo-Bin Lee
Gwo-Bin Lee

1 November 2014 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
CWChen-Hsun Weng
Chen-Hsun Weng
MCMing-Yi Chen
Ming-Yi Chen
CSChi-Hsiang Shen
Chi-Hsiang Shen
Ruey-Jen YangRuey-Jen Yang
Ruey-Jen Yang
Microfluidic paper-based analytical devices (μPADs) are widely used for performing diagnostic assays. However, in many assays, time-delay valves are required to improve the sensitivity and specificity of the results. Accordingly, this study presents a simple, low-cost method for realizing time-delay valves using a color wax printing process. In the proposed approach, the time-delay effect is controlled through a careful selection of both the color and the saturation of the wax content. The validity of the proposed method is demonstrated by performing nitrite and oxalate assays using both a simple two-dimensional μPAD and a three-dimensional μPAD incorporating a colored wax-printed timer. The experimental results confirm that the flow time can be controlled through an appropriate selection of the color and the wax content. In addition, it is shown that nitrite and oxalate assays can be performed simultaneously on a single device. In general, the results presented in this study show that the proposed μPADs provide a feasible low-cost alternative to conventional methods for performing diagnostic assays.