Peng Chen

Prof. Dr. Peng Chen


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CWChunjie Wang
Chunjie Wang
LGLinghao Guo
Linghao Guo
PCPeng Chen
Peng Chen
QFQiang Fu
Qiang Fu
Lin CuiLin Cui
Lin Cui
To sustainably power ocean sensors by harvesting ocean wave energy, an annular electromagnetic generator (A-EMG) based on the principle of Faraday electromagnetic induction is proposed in this paper. The specific structure and working principle of the generator are introduced. The distribution of the magnetic field in the coil, the variation in the induced voltage and the influence of the coil parameters on the output were simulated by the COMSOL Multiphysics software version 6.0. At the same time, an experimental platform was built to test the output characteristics of the generator. Through a comparative study of the capacitor’s charging characteristics, the optimal connection mode between the multiple groups of coils of the generator was preliminarily verified. Finally, the six-degree-of-freedom (6-DOF) platform was used to simulate various wave motion parameters, and the feasibility of the generator for supplying power to ocean sensors was verified.

Verified
Journal Article
Open access
PDF file
PCPeng Chen
Peng Chen
JZJiajin Zou
Jiajin Zou
CWChunjie Wang
Chunjie Wang
QFQiang Fu
Qiang Fu
LCLin Cui
Lin Cui
LMLishan Ma
Lishan Ma
Hydrogen production from water electrolysis can not only reduce greenhouse gas emissions, but also has abundant raw materials, which is one of the ideal ways to produce hydrogen from new energy. The hydrogen production power supply is the core component of the new energy electrolytic water hydrogen production device, and its characteristics have a significant impact on the efficiency and purity of hydrogen production and the service life of the electrolytic cell. In essence, the DC/DC converter provides the large current required for hydrogen production. For the converter, its input still needs the support of a DC power supply. Given the maturity and technical characteristics of new energy power generation, integrating energy storage into offshore energy systems enables stable power supply. This configuration not only mitigates energy fluctuations from renewable sources but also further reduces electrolysis costs, providing a feasible pathway for large-scale commercialization of green hydrogen production. First, this paper performs a simulation analysis on the wind–solar hybrid energy storage power generation system to demonstrate that the wind–solar–storage system can provide stable power support. It places particular emphasis on the significance of hydrogen production power supply design—this focus stems primarily from the fact that electrolyzers impose specific requirements on high operating current levels and low current ripple, which exert a direct impact on the electrolyzer’s service life, hydrogen production efficiency, and operational safety. To suppress the current ripple induced by high switching frequency and high output current, traditional approaches typically involve increasing the output inductor. However, this method substantially increases the volume and weight of the device, reduces the rate of current change, and ultimately results in a degradation of the system’s dynamic response performance. To this end, this paper focuses on developing a virtual impedance control technology, aiming to reduce the ripple amplitude while avoiding an increase in the filter inductor. Owing to constraints in current experimental conditions, this research temporarily relies on simulation data. Specifically, a programmable power supply is employed to simulate the voltage output of the wind–solar–storage hybrid system, thereby bringing the simulation as close as possible to the actual operating conditions of the wind–solar–storage hydrogen production system. The experimental results demonstrate that the proposed method can effectively suppress the ripple amplitude, maintain high operating efficiency, and ultimately meet the expected research objectives. That makes it particularly suitable as a high-quality power supply for offshore hydrogen production systems that have strict requirements on volume and weight.

8 December 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PCPeng Chen
Peng Chen
QFQiang Fu
Qiang Fu
CWChunjie Wang
Chunjie Wang
In recent years, the growing interest in renewable energy has increased attention on photovoltaic systems. While traditional photovoltaic systems are typically built on the ground, floating photovoltaic power generation involves placing photovoltaic panels on floating platforms in water. When these platforms are on the sea surface, the solar radiation received by the photovoltaic array changes periodically due to ocean waves, leading to fluctuations in the maximum power point temperature and light radiation. This results in varying power generation capacities and an unbalanced energy supply at different locations. The current fixed DC bus voltage further exacerbates this issue, reducing power generation efficiency. A new multi-winding permanent magnet synchronous motor (MWPMSM) system for distributed energy is proposed to address these challenges. This system features multiple independent DC buses, each operating at a different voltage level to ensure compatibility with the energy absorbed by each part of the photovoltaic array. The MWPMSM system is designed with a specific structure and mathematical model, and its structure parameters are carefully chosen and verified through finite element analysis. A control strategy for the MWPMSM is then established, and an experimental platform is used to demonstrate that the system maintains high efficiency and unchanged output power while ensuring a balanced power ratio (the Maximum error of winding power ratio is 6.7%).

1 January 2025 in Marine Energy Research
Verified
Journal Article
Open access
PDF file
CWChunjie Wang
Chunjie Wang
LZLaidong Zhang
Laidong Zhang
QXQiuyue Xu
Qiuyue Xu
PCPeng Chen
Peng Chen
SCIEPublish is an international open-access journal publishing service provider run by SCIE Publishing Limited, dedicated to supporting and inspiring scientists or institutions/societies who aspire to publish high-quality journals.

20 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
PCPeng Chen
Peng Chen
QFQiang Fu
Qiang Fu
CWChunjie Wang
Chunjie Wang
YZYaning Zhu
Yaning Zhu
With the expansion of urban rail transit, increased train operation density, and the large-scale grid integration of renewable energy such as offshore photovoltaic power, traction power supply systems face stricter requirements for operational safety, power supply reliability and energy utilization efficiency. Offshore photovoltaic power, integrated into the traction power supply network via flexible DC transmission technology, promotes renewable energy consumption, but its random and volatile output overlaps with time-varying traction loads, increasing the complexity of DC-side fault characteristics and protection control. Flexible DC technology is a core direction for next-generation traction substations, and three-level converters (key energy conversion units) have advantages over traditional two-level topologies. However, their P-O-N three-terminal DC-side topology introduces new faults (e.g., PO/ON bipolar short circuits, O-point-to-ground faults), making traditional protection strategies ineffective. In addition, wide system current fluctuation (0.5–3 kA) and offshore photovoltaic power fluctuation easily cause fixed-threshold protection maloperation, and the coupling mechanism among modulation strategies, DC bus capacitor voltage dynamics and fault current paths is unclear. To solve these bottlenecks, this paper establishes a simulation model of the system based on the PSCAD/EMTDC(A professional simulation software for electromagnetic transient analysis in power systems V4.5.3) platform, analyzes the transient electrical characteristics of three-level converters under traction and braking conditions for typical faults, clarifies the coupling mechanism, proposes a condition-adaptive fault identification strategy, and designs a reconfigurable fault energy handling system with bypass thyristors and adaptive crowbar circuits. Simulation and hardware-in-the-loop (HIL) experiments show that the proposed scheme completes fault identification and protection within 2–3 ms, suppresses fault peak current by more than 70%, limits DC bus overvoltage within ±10% of the rated voltage, and has good post-fault recovery performance. It provides a reliable and engineering-feasible protection solution for related systems and technical references for similar flexible DC system protection design.