Chenkai Li

Dr. Chenkai Li


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CLChenkai Li
Chenkai Li
ZZZian Zhang
Zian Zhang
GWGuanrong Wang
Guanrong Wang
CRChun Rong
Chun Rong
WZWanping Zhu
Wanping Zhu
HZHaining Zhang
Haining Zhang
Objective: This study assessed the accuracy of robotic-arm-assisted total knee arthroplasty (RATKA) for bone resection, component size prediction, implant placement, and limb alignment. Methods: This prospective cohort study included 36 patients. All procedures were performed by a single experienced surgeon, using an identical approach and implant designs. The MAKO RIO Robotic Interactive Orthopaedic Arm (Stryker, Mahwah, NJ, USA) system was used. The actual bone resection, implant placement, component size, and postoperative mechanical alignment were recorded, then compared with the preoperative plan. Results: The mean absolute differences from the plan for the distal (medial and lateral) and posterior (medial and lateral) femoral cuts were 0.39 mm (0.62), 0.49 mm (0.70), 0.62 mm (0.79), and 0.65 mm (0.81), respectively, with 0.57° (0.65) varus. The mean absolute differences in the medial and lateral tibial cuts were 0.56 mm (0.75) and 0.58 mm (0.76), with 0.48° (0.16) varus and 0.54° (0.25) anterior/posterior slope. Of 192 bone resections, 176 (91.7%) were within ≤ 1 mm of the preoperative plan. The accuracies of femoral and tibial component size prediction were 100% and 97.22%, respectively. The mean absolute difference in final limb coronal alignment was 0.92° (0.65). Of the alignments, 18 (75.0%) were within ≤ 1.00° of the plan, and 100% were within ≤ 3.00° of the plan. Conclusion: RATKA could accurately predict the component size and execute a preoperative plan to achieve precise bone resection, and implant placement, thereby reducing alignment outliers.


10 October 2020 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CLChenkai Li
Chenkai Li
HZHaining Zhang
Haining Zhang
Background: Highly cross-linked polyethylene (HXLPE) enhances the anti-wear characteristics of the conventional polyethylene (PE). Early failure for wear after ceramic-on-highly cross-linked polyethylene (CoHXLPE) total hip arthroplasty (THA) is extremely rare. Case presentation: We described the case of a 60-year-old man who underwent right CoHXLPE THA because of the developmental dysplasia hip (DDH) complained pain 32 months after this procedure. Plain radiographs showed that eccentric wear existed at the polyethylene insert. However, the patient refused surgery at that time and did not stop weight-bearing. The right hip pain continued for 7 months. Plain radiographs of the pelvis showed that the HXLPE liner was penetrated and partial inner wall of acetabular shell was worn. Acetabular cup revision was performed, and the ceramic head and HXLPE were exchanged. Conclusions: Difficult reduction during primary THA, especially for DDH, can result in higher abductor tension, which may lead to early eccentric wear of the prosthesis. Whenever eccentric wear of HXLPE liner was found, weight-bearing must be stopped to avoid the accelerated wear and adverse reactions to metal debris (ARMD).

22 February 2022 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
TLTao Li
Tao Li
YLYikai Liu
Yikai Liu
CLChenkai Li
Chenkai Li
HZHaining Zhang
Haining Zhang
Objective: This study was performed to compare clinical outcomes among patients with valgus knees undergoing total knee arthroplasty via the medial parapatellar approach and the subvastus with minimal oblique cut approach.Methods: A total of 232 patients (246 knees) undergoing total knee arthroplasty between December 2014 and December 2016 were retrospectively included in the investigation. The study population consisted of 120 patients (128 knees; 32 men and 88 women) with a mean age of 62.43 ± 8.12 years treated via the medial parapatellar approach, and 112 patients (118 knees; 30 men and 82 women with a mean age of 63.15 ± 7.83 years) treated via the subvastus with minimal oblique cut approach. Nine preoperative parameters (number of patients, sex, age, body mass index, number of knees, valgus angle, visual analogue scale score, range of motion, Hospital for Special Surgery score), five perioperative parameters (operative time, amount of drainage, Visual analogue scale score at 24 h after the operation, time to straight leg raising, radiological alignment), and two postoperative parameters (range of motion, Hospital for Special Surgery score) were assessed at 1 day, 1 week, 6 weeks, 8 weeks and 1 year after the operation, along with postoperative complications.Results: There were no significant differences in the nine preoperative parameters between the two groups. The subvastus with minimal oblique cut group had a longer operative time, while the parapatellar approach group showed more drainage and a higher mean Visual analogue scale score. Compared to the medial parapatellar group, the subvastus with minimal oblique cut group had a shorter time to straight leg raising. There were no differences in radiological alignment between the two groups. The groups showed similar range of motion and Hospital for Special Surgery scores at 8 weeks and 1 year, but both were higher in the subvastus with minimal oblique cut group at 1 day, 1 week and 6 weeks. During postoperative follow-up, postoperative subluxation of the patella occurred in five cases in the medial parapatellar group. Neither group showed any instability, recurrent valgus deformity or radiographic loosening.Conclusion: The subvastus with minimal oblique cut approach provides excellent early recovery for total knee arthroplasty of valgus knees with no increase in complications.

4 October 2023 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CLChenkai Li
Chenkai Li
YDYou Du
You Du
SWShengru Wang
Shengru Wang
JZJianguo Zhang
Jianguo Zhang
YYYang Yang
Yang Yang
XYXiaohan Ye
Xiaohan Ye
Objective: The literature currently available on the characteristics of patients who require intensive care unit (ICU) admission after correction surgery for adult spinal deformity is lacking; this study aimed to identify risk factors for postoperative ICU admission following correction surgery for adult spinal deformity. Methods: A retrospective review of patients who underwent primary posterior-based spinal fusion from 2015 to 2023 was performed. According to the ward they returned to, patients were further divided into an ICU group and a non-ICU group. Univariate and multivariate analyses were performed to evaluate preoperative and perioperative parameters to identify independent risk factors for postoperative ICU admission in adult spinal deformity patients. Results: A total of 274 patients were included, including 115 males (41.97%) and 159 females (58.03%). The mean age of the patients was 32.00 ± 11.16 years (19–77 years). Following adjusted analysis, the preoperative and perioperative factors that were independently associated with ICU admission were age, body mass index ≥ 28 kg/m2, neuromuscular spinal deformity, respiratory disease, grade III-IV American Society of Anesthesiologists (ASA) classification, a scoliosis Cobb angle ≥ 90°, a kyphosis Cobb angle ≥ 90°, and ≥ 12 fused segments. Compared with the non-ICU group, the ICU group had a higher incidence of complications, a longer hospital stay, and higher medical costs (P < 0.05). Conclusion: This study identified independent risk factors associated with postoperative ICU admission in adult spinal deformity patients; and explored relative measures to decrease or avoid the risk of postoperative ICU admission. Surgeons could use these data to develop and plan appropriate perioperative care processes in advance and provide consultation for family members before surgery.

8 November 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CLChenkai Li
Chenkai Li
TLTao Li
Tao Li
ZZZian Zhang
Zian Zhang
HHHui Huang
Hui Huang
TCtian chen
tian chen
HZHaining Zhang
Haining Zhang
Background: Bearing dislocation is the main complication after mobile bearing unicompartmental knee arthroplasty. The purpose of this study was to analyze the potential risk factors of bearing dislocation after Oxford phase III mobile bearing unicompartmental knee arthroplasty in Chinese patients. Methods: We retrospectively investigated 492 patients (578 knees) who underwent Oxford phase III mobile bearing unicompartmental knee arthroplasty in our institution between February 2009 and June 2019. The patients were divided into two groups based on surgeons’ annual surgical volume. Those with/ without bearing dislocation were compared based on patient, surgeon and implant factors. Results: Among the 492 patients, 21 (4.3%, 4 men and 17 women) experienced bearing dislocation. Of these, 14 (4.0%) were in the high surgical volume group and 7 (5.1%) were in the low surgical volume group. Multivariate analysis revealed that trauma to the operated leg and daily life involving high knee flexion cumulatively predicted bearing dislocation (p < 0.05). Conclusions: Trauma to the operated leg and daily life involving high knee flexion were risk factors for bearing dislocation after Oxford phase III mobile bearing unicompartmental knee arthroplasty.