Chris Hoi Houng Chan

Dr. Chris Hoi Houng Chan

Texas Heart Institute, Baylor College of Medicine, Houston, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
IPIna Laura Pieper
Ina Laura Pieper
CRChristian R. Robinson
Christian R. Robinson
YFYasmin Friedmann
Yasmin Friedmann
VKVenkateswarlu Kanamarlapudi
Venkateswarlu Kanamarlapudi
CTCatherine A. Thornton
Catherine A. Thornton

28 July 2014 in Artificial Organs
Verified
Journal Article
Open access
PDF file
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
IPIna Laura Pieper
Ina Laura Pieper
RHRebecca Hambly
Rebecca Hambly
GRGemma Radley
Gemma Radley
AJAlyssa Jones
Alyssa Jones
CTCatherine A. Thornton
Catherine A. Thornton
Implantable ventricular assist devices (VADs) have proven efficient in advanced heart failure patients as a bridge‐to‐transplant or destination therapy. However, VAD usage often leads to infection, bleeding, and thrombosis, side effects attributable to the damage to blood cells and plasma proteins. Measuring hemolysis alone does not provide sufficient information to understand total blood damage, and research exploring the impact of currently available pumps on a wider range of blood cell types and plasma proteins such as von Willebrand factor (vWF) is required to further our understanding of safer pump design. The extracorporeal CentriMag (Thoratec Corporation, Pleasanton, CA, USA) has a hemolysis profile within published standards of normalized index of hemolysis levels of less than 0.01 g/100 L at 100 mm Hg but the effect on leukocytes, vWF multimers, and platelets is unknown. Here, the CentriMag was tested using bovine blood (n = 15) under constant hemodynamic conditions in comparison with a static control for total blood cell counts, hemolysis, leukocyte death, vWF multimers, microparticles, platelet activation, and apoptosis. The CentriMag decreased the levels of healthy leukocytes (P < 0.006), induced leukocyte microparticles (P < 10−5), and the level of high molecular weight of vWF multimers was significantly reduced in the CentriMag (P < 10−5) all compared with the static treatment after 6 h in vitro testing. Despite the leukocyte damage, microparticle formation, and cleavage of vWF multimers, these results show that the CentriMag is a hemocompatible pump which could be used as a standard in blood damage assays to inform the design of new implantable blood pumps.

1 January 2022 in Journal of Biomechanics
Verified
Journal Article
Open access
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
MSMichael J. Simmonds
Michael J. Simmonds
KFKatharine H. Fraser
Katharine H. Fraser
KIKosuke Igarashi
Kosuke Igarashi
KKKatrina K. Ki
Katrina K. Ki
NWNobuo Watanabe
Nobuo Watanabe
Despite decades of technological advancements in blood-contacting medical devices, complications related to shear flow-induced blood trauma are still frequently observed in clinic. Blood trauma includes haemolysis, platelet activation, and degradation of High Molecular Weight von Willebrand Factor (HMW vWF) multimers, all of which are dependent on the exposure time and magnitude of shear stress. Specifically, accumulating evidence supports that when blood is exposed to shear stresses above a certain threshold, blood trauma ensues; however, it remains unclear how various constituents of blood are affected by discrete shears experimentally. The aim of this study was to expose blood to discrete shear stresses and evaluate blood trauma indices that reflect red cell, platelet, and vWF structure. Citrated human whole blood (n = 6) was collected and its haematocrit was adjusted to 30 ± 2% by adding either phosphate buffered saline (PBS) or polyvinylpyrrolidone (PVP). Viscosity of whole blood was adjusted to 3.0, 12.5, 22.5 and 37.5 mPa·s to yield stresses of 3, 6, 9, 12, 50, 90 and 150 Pa in a custom-developed shearing system. Blood samples were exposed to shear for 0, 300, 600 and 900 s. Haemolysis was measured using spectrophotometry, platelet activation using flow cytometry, and HMW vWF multimer degradation was quantified with gel electrophoresis and immunoblotting. For tolerance to 300, 600 and 900 s of exposure time, the critical threshold of haemolysis was reached after blood was exposed to 90 Pa for 600 s (P < 0.05), platelet activation and HMW vWF multimer degradation were 50 Pa for 600 s and 12 Pa for 300 s respectively (P < 0.05). Our experimental results provide simultaneous comparison of blood trauma indices and thus also the relation between shear duration and magnitude required to induce damage to red cells, platelets, and vWF. Our results also demonstrate that near-physiological shear stress (<12 Pa) is needed in order to completely avoid any form of blood trauma. Therefore, there is an urgent need to design low shear-flow medical devices in order to avoid blood trauma in this blood-contacting medical device field.

19 September 2014 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
IPIna Laura Pieper
Ina Laura Pieper
SFScott Fleming
Scott Fleming
YFYasmin Friedmann
Yasmin Friedmann
GFGraham Foster
Graham Foster
VKVenkateswarlu Kanamarlapudi
Venkateswarlu Kanamarlapudi

25 April 2021 in Membranes
Verified
Journal Article
Open access
PDF file
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
KKKatrina K. Ki
Katrina K. Ki
MZMeili Zhang
Meili Zhang
CACooper Asnicar
Cooper Asnicar
HCHwa Jin Cho
Hwa Jin Cho
John Francis FraserJohn Francis Fraser
John Francis Fraser
In vitro hemolysis testing is commonly used to determine hemocompatibility of ExtraCorporeal Membrane Oxygenation (ECMO). However, poor reproducibility remains a challenging problem, due to several unidentified influencing factors. The present study investigated potential factors, such as flow rates, the use of anticoagulants, and gender of blood donors, which could play a role in hemolysis. Fresh human whole blood was anticoagulated with either citrate (n = 6) or heparin (n = 12; 6 female and 6 male blood donors). Blood was then circulated for 360 min at 4 L/min or 1.5 L/min. Regardless of flow rate conditions, hemolysis remained unchanged over time in citrated blood, but significantly increased after 240 min circulation in heparinized blood (p ≤ 0.01). The ratio of the normalized index of hemolysis (NIH) of heparinized blood to citrated blood was 11.7-fold higher at 4 L/min and 16.5–fold higher at 1.5 L/min. The difference in hemolysis between 1.5 L/min and 4 L/min concurred with findings of previous literature. In addition, the ratio of NIH of male heparinized blood to female was 1.7-fold higher at 4 L/min and 2.2-fold higher at 1.5 L/min. Our preliminary results suggested that the choice of anticoagulant and blood donor gender could be critical factors in hemolysis studies, and should be taken into account to improve testing reliability during ECMO.

31 July 2020 in Artificial Organs
Verified
Journal Article
Open access
PDF file
Chris Hoi Houng ChanChris Hoi Houng Chan
Chris Hoi Houng Chan
MIMasataka Inoue
Masataka Inoue
KKKatrina K. Ki
Katrina K. Ki
TMTomotaka Murashige
Tomotaka Murashige
JFJohn F. Fraser
John F. Fraser
NWNobuo Watanabe
Nobuo Watanabe
Nonsurgical bleeding is the most frequent complication of left ventricular assist device (LVAD) support. Supraphysiologic shear rates generated in LVAD causes impaired platelet aggregation, which increases the risk of bleeding. The effect of shear rate on the formation size of platelet aggregates has never been reported experimentally, although platelet aggregation size can be considered to be directly relevant to bleeding complications. Therefore, this study investigated the impact of shear rate and exposure time on the formation size of platelet aggregates, which is vital in predicting bleeding in patients with an LVAD. Human platelet‐poor plasma (containing von Willebrand factor, vWF) and fluorochrome‐labeled platelets were subjected to a range of shear rates (0‐10 000 s−1) for 0, 5, 10, and 15 minutes using a custom‐built blood‐shearing device. Formed sizes of platelet aggregates under a range of shear‐controlled environment were visualized and measured using microscopy. The loss of high molecular weight (HMW) vWF multimers was quantified using gel electrophoresis and immunoblotting. An inhibition study was also performed to investigate the reduction in platelet aggregation size and HMW vWF multimers caused by either mechanical shear or enzymatic (a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13—ADAMTS13, the von Willebrand factor protease) mechanism under low and high shear conditions (360 and 10 000 s−1). We found that the average size of platelet aggregates formed under physiological shear rates of 360‐3000 s−1 (200‐300 μm2) was significantly larger compared to those sheared at >6000 s−1 (50‐100 μm2). Furthermore, HMW vWF multimers were reduced with increased shear rates. The inhibition study revealed that the reduction in platelet aggregation size and HWM vWF multimers were mainly associated with ADAMTS13. In conclusion, the threshold of shear rate must not exceed >6000 s−1 in order to maintain the optimal size of platelet aggregates to “plug off” the injury site and stop bleeding.