Chun-Chieh Yip

Dr. Chun-Chieh Yip

Universiti Tunku Abdul Rahman, Kampar, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Case Studies in Construction Materials
Verified
Journal Article
Open access
SLSu-Shen Lim
Su-Shen Lim
JWJing-Ying Wong
Jing-Ying Wong
CYChun-Chieh Yip
Chun-Chieh Yip
JPJet-Wei Pang
Jet-Wei Pang

6 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
CYChun-Chieh Yip
Chun-Chieh Yip
JWJing Ying Wong
Jing Ying Wong
mugahed amranmugahed amran
mugahed amran
Roman FediukRoman Fediuk
Roman Fediuk
Nikolai Ivanovich VatinNikolai Ivanovich Vatin
Nikolai Ivanovich Vatin
Past historical earthquake events from neighbouring countries have been proven to be disastrous. Building in the aftermath of an earthquake may reduce structural reliability, posing risk upon re-occupation of the building. Shock absorber viscous dampers were installed on a specific structure storey that could reduce the spectral acceleration and storey-drift caused by an earthquake. The research object is a low-rise, three-storey, reinforced concrete (RC) structure. This study aims to identify the dynamic response of the scaled RC structure with and without attached dampers and performs structural reliability of the tested model under the excitation of Peak Ground Acceleration (PGA) of 0.1 g to 1.0 g with a unidirectional shaking table. APIDO viscous dampers were installed parallel to the movement direction of the dynamic load test. The findings show the scaled model with attached viscous dampers reduces spectral acceleration and storey drift by 9.66% and 4.85%, respectively. Findings also show the change of the structural behaviour from single curvature to double curvature due to the increase in seismic structural resistance by viscous dampers. The breakthrough of this research shows that structural reliability analysis performed by the Weibull distribution function has a base shear capacity increment of 1.29% and 6.90% in seismic performance level Life Safety (LS) and Collapse Prevention (CP), respectively. The novelty of this case study building with dampers managed to increase the building’s base shear and roof shear capacity by 6.90% and 16% compared to the building without dampers under dynamic load excitation.

21 October 2015 in Jurnal Teknologi (Sciences & Engineering)
Verified
Journal Article
Closed access
PDF file
CYChun-Chieh Yip
Chun-Chieh Yip
AMAbdul Kadir Marsono
Abdul Kadir Marsono
JWJing-Ying Wong
Jing-Ying Wong
mugahed amranmugahed amran
mugahed amran
Special reinforced lightweight aggregate concrete (SRLWAC) beam is designed as beam component in Industrialised Building System (IBS). It is used to overcome the difficulties during the component installation due to the heavy lifting task. This paper presents the flexural strength and performance of SRLWAC beam under vertical static load. SRLWAC beam was set-up on two columns corbel and tested under monotonic vertical load. Five Linear Variable Displacement Transducers (LVDTs) were instrumented in the model to record displacement. The ultimate flexural capacity of the beam was obtained at the end of experiment where failure occurred. Performance of the beam was evaluated in load-displacement relationship of beam and mode of failure. SRLWAC beam was then modelled and simulated by nonlinear finite element software- Autodesk Simulation Mechanical. Result from finite element analysis was verified by experimental result. Maximum mid-span displacement, Von-Mises stress, concrete maximum principal stress, and yielding strength of reinforcement were discussed in this paper. The beam was behaved elastically up to 90 kN and deformed plastically until ultimate capacity of 250.1 kN in experimental test. The maximum mid span displacement for experimental and simulation were 15.21 mm and 15.36 mm respectively. The major failure of IBS SRLWAC beam was the splitting of the concrete and yielding of main reinforcements at overlay end. Ductility ratio of IBS SRLWAC beam was 14.2, which was higher than pre-stressed concrete beam.

9 April 2020 in Science Proceedings Series
Verified
Journal Article
Open access
PDF file
YGYann Ling Goh
Yann Ling Goh
YGYeh Huann Goh
Yeh Huann Goh
CYChun-Chieh Yip
Chun-Chieh Yip
CTChen Hunt Ting
Chen Hunt Ting
RBRaymond Ling Leh Bin
Raymond Ling Leh Bin
KCKah Pin Chen
Kah Pin Chen
Schooling system must provide high quality learning opportunities to meet the educational needs and ensuring achievement for every student. All teachers monitor their students’ progress throughout the year, includes formative assessment, questioning, providing feedback, etc. This practice helps teachers continually assess students’ academic performance and evaluate the effectiveness of their teaching. In this paper, k-means clustering method with deterministic model is used to analyze the student's overall performance. The results is important for educators to identify students who are at risk academically and areas where teaching strategies may need adjustment to better meet these students' needs.

5 June 2023 in Journal of Building Engineering
Verified
Journal Article
Open access
MSMirza Rayana Sanzana
Mirza Rayana Sanzana
MAMostafa Osama Mostafa Abdulrazic
Mostafa Osama Mostafa Abdulrazic
JWJing Ying Wong
Jing Ying Wong
TMTomas Maul
Tomas Maul
CYChun-Chieh Yip
Chun-Chieh Yip

13 December 2017 in Jurnal Teknologi (Sciences & Engineering)
Verified
Journal Article
Closed access
PDF file
CYChun-Chieh Yip
Chun-Chieh Yip
AMAbdul Kadir Marsono
Abdul Kadir Marsono
JWJing Ying Wong
Jing Ying Wong
SLShu-Chi Lee
Shu-Chi Lee
This paper presents the seismic performance of the down scaled 1:5 model IBS block column with non-linear static analysis. The aim of this research is to access the ultimate capacity and structural behaviour of the IBS block column. This paper demonstrates the theoretical prediction of the full-scale prototype strength based on scaling factors at non-linear state. Besides, this research investigates the ultimate shear capacity, stiffness, bolt strength, inter-storey drift and block separation for prediction of seismic performance levels. Concrete material properties, mix specification and steel reinforcement detailing for scaled model are tabulated in this paper. The methodology of this research begins with full scale prototype design, scaling to the small model and followed by the scaled model fabrication. Theoretical lateral load prediction associated with scaling factors are also performed. The experiment test was carried out on the assembled scaled 1:5 IBS block column with proper displacement measuring equipment on test rig and graphical capture tools. The data of roof top displacement with base shear capacity, inter-storey drift and gap separations were tabulated for discussions. The tested ultimate roof top displacement was 128 mm with 3.1 kN base shear. The calculated elastic stiffness of the IBS block column was 0.137 kN/mm, followed by yielding stiffness of 0.033 kN/mm and 0.014 kN/mm plastic stiffness. The significant inter-storey drift was due to cracking and crushing of column blocks edges. The measured maximum separation gap was 24.4 mm located at 340 mm height due to the rocking of the column. Based on seismic performance levels indicator from FEMA 273 & 356, the column was in the state of immediate occupancy with 21 mm roof top displacement and 1.7 kN base shear. The life safety is limited at 65.27 mm roof top displacement with 2.4 kN of base shear. All scaled down data was then reverted to full scale prototype capacity according with the respective scaling factors. It concluded that the IBS blockwork column is capable of resisting the seismic event without falling of the blocks that endanger the occupant life at the maximum credible earthquakes of 1.3 g horizontal spectral acceleration equivalent to X+ Mercalli’s scale.