Claudia Ferraris

Dr. Claudia Ferraris

IEIIT, National Research Council, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GMGiulia Masi
Giulia Masi
GAGianluca Amprimo
Gianluca Amprimo
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
LPLorenzo Priano
Lorenzo Priano
In aviation, any detail can have massive consequences. Among the potential sources of failure, human error is still the most troublesome to handle. Therefore, research concerning the management of mental workload, attention, and stress is of special interest in aviation. Recognizing conditions in which a pilot is over-challenged or cannot act lucidly could avoid serious outcomes. Furthermore, knowing in depth a pilot’s neurophysiological and cognitive–behavioral responses could allow for the optimization of equipment and procedures to minimize risk and increase safety. In addition, it could translate into a general enhancement of both the physical and mental well-being of pilots, producing a healthier and more ergonomic work environment. This review brings together literature on the study of stress and workload in the specific case of pilots of both civil and military aircraft. The most common approaches for studying these phenomena in the avionic context are explored in this review, with a focus on objective methodologies (e.g., the collection and analysis of neurophysiological signals). This review aims to identify the pros, cons, and applicability of the various approaches, to enable the design of an optimal protocol for a comprehensive study of these issues.

4 June 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
GAGianluca Amprimo
Gianluca Amprimo
GMGiulia Masi
Giulia Masi
GPGiuseppe Pettiti
Giuseppe Pettiti
Gabriella OlmoGabriella Olmo
Gabriella Olmo
LPLorenzo Priano
Lorenzo Priano
Claudia FerrarisClaudia Ferraris
Claudia Ferraris

5 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
RNRoberto NERINO
Roberto NERINO
ACAntonio Chimienti
Antonio Chimienti
GPGiuseppe Pettiti
Giuseppe Pettiti
NCNicola Cau
Nicola Cau
AMAlessandro Mauro
Alessandro Mauro
A self-managed, home-based system for the automated assessment of a selected set of Parkinson’s disease motor symptoms is presented. The system makes use of an optical RGB-Depth device both to implement its gesture-based human computer interface and for the characterization and the evaluation of posture and motor tasks, which are specified according to the Unified Parkinson’s Disease Rating Scale (UPDRS). Posture, lower limb movements and postural instability are characterized by kinematic parameters of the patient movement. During an experimental campaign, the performances of patients affected by Parkinson’s disease were simultaneously scored by neurologists and analyzed by the system. The sets of parameters which best correlated with the UPDRS scores of subjects’ performances were then used to train supervised classifiers for the automated assessment of new instances of the tasks. Results on the system usability and the assessment accuracy, as compared to clinical evaluations, indicate that the system is feasible for an objective and automated assessment of Parkinson’s disease at home, and it could be the basis for the development of neuromonitoring and neurorehabilitation applications in a telemedicine framework.

21 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Luca VismaraLuca Vismara
Luca Vismara
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
GAGianluca Amprimo
Gianluca Amprimo
GPGiuseppe Pettiti
Giuseppe Pettiti
LPLorenzo Priano
Lorenzo Priano
The accurate and reliable assessment of gait parameters is assuming an important role, especially in the perspective of designing new therapeutic and rehabilitation strategies for the remote follow-up of people affected by disabling neurological diseases, including Parkinson’s disease and post-stroke injuries, in particular considering how gait represents a fundamental motor activity for the autonomy, domestic or otherwise, and the health of neurological patients. To this end, the study presents an easy-to-use and non-invasive solution, based on a single RGB-D sensor, to estimate specific features of gait patterns on a reduced walking path compatible with the available spaces in domestic settings. Traditional spatio-temporal parameters and features linked to dynamic instability during walking are estimated on a cohort of ten parkinsonian and eleven post-stroke subjects using a custom-written software that works on the result of a body-tracking algorithm. Then, they are compared with the “gold standard” 3D instrumented gait analysis system. The statistical analysis confirms no statistical difference between the two systems. Data also indicate that the RGB-D system is able to estimate features of gait patterns in pathological individuals and differences between them in line with other studies. Although they are preliminary, the results suggest that this solution could be clinically helpful in evolutionary disease monitoring, especially in domestic and unsupervised environments where traditional gait analysis is not usable.

18 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
RNRoberto NERINO
Roberto NERINO
ACAntonio Chimienti
Antonio Chimienti
GPGiuseppe Pettiti
Giuseppe Pettiti
NCNicola Cau
Nicola Cau
AMAlessandro Mauro
Alessandro Mauro
A home-based, reliable, objective and automated assessment of motor performance of patients affected by Parkinson’s Disease (PD) is important in disease management, both to monitor therapy efficacy and to reduce costs and discomforts. In this context, we have developed a self-managed system for the automated assessment of the PD upper limb motor tasks as specified by the Unified Parkinson’s Disease Rating Scale (UPDRS). The system is built around a Human Computer Interface (HCI) based on an optical RGB-Depth device and a replicable software. The HCI accuracy and reliability of the hand tracking compares favorably against consumer hand tracking devices as verified by an optoelectronic system as reference. The interface allows gestural interactions with visual feedback, providing a system management suitable for motor impaired users. The system software characterizes hand movements by kinematic parameters of their trajectories. The correlation between selected parameters and clinical UPDRS scores of patient performance is used to assess new task instances by a machine learning approach based on supervised classifiers. The classifiers have been trained by an experimental campaign on cohorts of PD patients. Experimental results show that automated assessments of the system replicate clinical ones, demonstrating its effectiveness in home monitoring of PD.

4 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Claudia FerrarisClaudia Ferraris
Claudia Ferraris
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Luca VismaraLuca Vismara
Luca Vismara
VVValerio Votta
Valerio Votta
GAGianluca Amprimo
Gianluca Amprimo
LPLorenzo Priano
Lorenzo Priano
Stroke is one of the most significant causes of permanent functional impairment and severe motor disability. Hemiplegia or hemiparesis are common consequences of the acute event, which negatively impacts daily life and requires continuous rehabilitation treatments to favor partial or complete recovery and, consequently, to regain autonomy, independence, and safety in daily activities. Gait impairments are frequent in stroke survivors. The accurate assessment of gait anomalies is therefore crucial and a major focus of neurorehabilitation programs to prevent falls or injuries. This study aims to estimate, using a single RGB-D sensor, gait patterns and parameters on a short walkway. This solution may be suitable for monitoring the improvement or worsening of gait disorders, including in domestic and unsupervised scenarios. For this purpose, some of the most relevant spatiotemporal parameters, estimated by the proposed solution on a cohort of post-stroke individuals, were compared with those estimated by a gold standard system for a simultaneous instrumented 3D gait analysis. Preliminary results indicate good agreement, accuracy, and correlation between the gait parameters estimated by the two systems. This suggests that the proposed solution may be employed as an intermediate tool for gait analysis in environments where gold standard systems are impractical, such as home and ecological settings in real-life contexts.