Claudia Frick

Dr. Claudia Frick

Max Planck Institute for Developmental Biology
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2012 in Histochemistry and Cell Biology
Verified
Journal Article
Closed access
HBHeinz Breer
Heinz Breer
JEJ. Eberle
J. Eberle
Claudia FrickClaudia Frick
Claudia Frick
DHD. Haid
D. Haid
PWP. Widmayer
P. Widmayer

1 January 2017 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
Claudia FrickClaudia Frick
Claudia Frick
MMMarcus Müller
Marcus Müller
UWUte Wank
Ute Wank
ATAnke Tropitzsch
Anke Tropitzsch
BKBenedikt Kramer
Benedikt Kramer
HLHubert Löwenheim
Hubert Löwenheim

1 September 2017 in Otology & Neurotology
Verified
Journal Article
Open access
PSPascal Senn
Pascal Senn
MRMarta Roccio
Marta Roccio
SHStefan Hahnewald
Stefan Hahnewald
Claudia FrickClaudia Frick
Claudia Frick
MKMonika Kwiatkowska
Monika Kwiatkowska
HLHubert Löwenheim
Hubert Löwenheim
Cochlear implants (CI) restore functional hearing in the majority of deaf patients. Despite the tremendous success of these devices, some limitations remain. The bottleneck for optimal electrical stimulation with CI is caused by the anatomical gap between the electrode array and the auditory neurons in the inner ear. As a consequence, current devices are limited through 1) low frequency resolution, hence sub-optimal sound quality and 2), large stimulation currents, hence high energy consumption (responsible for significant battery costs and for impeding the development of fully implantable systems). A recently completed, multinational and interdisciplinary project called NANOCI aimed at overcoming current limitations by creating a gapless interface between auditory nerve fibers and the cochlear implant electrode array. This ambitious goal was achieved in vivo by neurotrophin-induced attraction of neurites through an intracochlear gel-nanomatrix onto a modified nanoCI electrode array located in the scala tympani of deafened guinea pigs. Functionally, the gapless interface led to lower stimulation thresholds and a larger dynamic range in vivo, and to reduced stimulation energy requirement (up to fivefold) in an in vitro model using auditory neurons cultured on multi-electrode arrays. In conclusion, the NANOCI project yielded proof of concept that a gapless interface between auditory neurons and cochlear implant electrode arrays is feasible. These findings may be of relevance for the development of future CI systems with better sound quality and performance and lower energy consumption. The present overview/review paper summarizes the NANOCI project history and highlights achievements of the individual work packages.

20 December 2017 in Cell and tissue research
Verified
Journal Article
Open access
PDF file
KLKerstin Lang
Kerstin Lang
HBHeinz Breer
Heinz Breer
Claudia FrickClaudia Frick
Claudia Frick
G cells in the antrum region of the murine stomach produce gastrin, the central hormone for controlling gastric activities. Secretion of gastrin is induced mainly by protein breakdown products but also by distensions of the stomach wall. Although G cells respond to protein fragments via distinct chemosensory receptor types, the mechanism underlying G cell activation upon distention is entirely ambiguous. Mechanosensitive ion channels are considered as potential candidates for such a task. Therefore, we explore the possibility of whether Piezo1, a polymodal sensor for diverse mechanical forces, is expressed in antral G cells. The experimental analyses revealed that the vast majority of G cells indeed expressed Piezo1. Within flask-like G cells at the base of the antral invaginations, the Piezo1 protein was primarily located at the basolateral portion, which is thought to be the release site for the exocytic secretion of gastrin. In the spindle-like G cells, which are oriented parallel to the invaginations, Piezo1 protein was restricted to the cell body where the hormone was also located, whereas the long processes appeared to be devoid of Piezo1 protein. Our results suggest that mechanosensitive channels such as Piezo1, located in close proximity to hormone-release sites, enable G cells to respond directly to antrum distensions with gastrin secretion.

1 October 2015 in Journal of Neuroscience Methods
Verified
Journal Article
Open access
PBPeter Bako
Peter Bako
MBMohamed Bassiouni
Mohamed Bassiouni
AEAndreas Eckhard
Andreas Eckhard
IGImre Gerlinger
Imre Gerlinger
Claudia FrickClaudia Frick
Claudia Frick
MMMarcus Müller
Marcus Müller
Histological analysis of the cochlea is required to understand the physiological and pathological processes in the inner ear. In the past, many embedding techniques have been tested in the cochlea to find an optimal protocol that gives both good morphological and immunohistochemical results. Resins provide high quality cochlear morphology with reduced immunogenicity due to the higher polymerization temperature. We used Technovit 9100 New(®), a low temperature embedding system based on methyl methacrylate, on adult guinea pig and mouse cochleae to evaluate preservation of the morphology and maintenance of the antigenicity. Conventional toluidine blue staining, as well as immunohistochemical staining with a set of commonly used antibodies, showed highly preserved morphology and immunogenicity of decalcified adult guinea pig and mouse cochleae. We demonstrate both, well-preserved morphology and preservation of antigenicity, superior to other embedding techniques. Our results showed that the Technovit 9100 New(®) embedding system provided highly preserved morphology and immunogenicity with our protocol in adult guinea pig and mouse cochleae.

1 December 2015 in Hearing Balance and Communication
Verified
Journal Article
Closed access
PDF file
AHAlexandra Homsy
Alexandra Homsy
ELEdith Laux
Edith Laux
JBJulien Brossard
Julien Brossard
HWHarry J. Whitlow
Harry J. Whitlow
MRMarta Roccio
Marta Roccio
HKHerbert Keppner
Herbert Keppner
Cochlear implants are neuroprostheses that are inserted into the inner ear to directly electrically stimulate the auditory nerve, thus replacing lost cochlear receptors, the hair cells. The reduction of the gap between electrodes and nerve cells will contribute to technological solutions simultaneously increasing the frequency resolution, the sound quality and the amplification of the signal. Recent findings indicate that neurotrophins (NTs) such as brain derived neurotrophic factor (BDNF) stimulate the neurite outgrowth of auditory nerve cells by activating Trk receptors on the cellular surface (1–3). Furthermore, small-size TrkB receptor agonists such as di-hydroxyflavone (DHF) are now available, which activate the TrkB receptor with similar efficiency as BDNF, but are much more stable (4). Experimentally, such molecules are currently used to attract nerve cells towards, for example, the electrodes of cochlear implants. This paper analyses the scenarios of low dose aspects of controlled release of small-size Trk receptor agonists from the coated CI electrode array into the inner ear. The control must first ensure a sufficient dose for the onset of neurite growth. Secondly, a gradient in concentration needs to be maintained to allow directive growth of neurites through the perilymph-filled gap towards the electrodes of the implant. We used fluorescein as a test molecule for its molecular size similarity to DHF and investigated two different transport mechanisms of drug dispensing, which both have the potential to fulfil controlled low-throughput drug-deliverable requirements. The first is based on the release of aqueous fluorescein into water through well-defined 60-μm size holes arrays in a membrane by pure osmosis. The release was both simulated using the software COMSOL and observed experimentally. In the second approach, solid fluorescein crystals were encapsulated in a thin layer of parylene (PPX), hence creating random nanometer-sized pinholes. In this approach, the release occurred due to subsequent water diffusion through the pinholes, dissolution of the fluorescein and then release by out-diffusion. Surprisingly, the release rate of solid fluorescein through the nanoscopic scale holes was found to be in the same order of magnitude as for liquid fluorescein release through microscopic holes.