This paper deals with an analytical model to evaluate the noncharacteristic harmonics that are generated by three-phase three-wire voltage-source converters (VSCs) operating under unbalanced sinusoidal voltage conditions. This model permits the calculation of the oscillating current on the VSC dc side by considering the unbalanced voltages on its ac side. It can be used to prove that the use of dc voltage control techniques to eliminate VSC dc-side double frequency voltage ripple necessarily creates three-phase currents with undesirable low-frequency harmonic components on the VSC ac side. In this paper, the attention is directed to the instantaneous oscillating real power component at twice the line frequency, rather than to other power components. The noncharacteristic current components analyzed in this paper, such as the fundamental negative sequence and third-order harmonic components of positive and negative sequences are calculated using the proposed model in time-domain simulations. A simple model to calculate the dc-side capacitor to mitigate these noncharacteristic harmonic problems is presented.
This paper presents an analytical model of typical three-phase, three-leg, four-wire and two-level PWM controlled voltage-source converters (VSCs) suitable to investigate the harmonic generation at dc- and ac-side of the converter under sinusoidal unbalanced current condition, e.g., positive-sequence third order harmonic voltage in the VSC ac-side. The proposed model, based on instantaneous power theory as well as switching functions concepts, permits to evaluate the oscillating voltage that appears on the VSC dc-side. The effect of the zero- and negative-sequence current components are considered on the dc capacitance calculation which consequently enables to size the dc capacitor accurately in order to keep the dc voltage ripple of each split capacitor under pre-defined limits. The model also shows the exact dc-side voltage ripple due to the VSC ac-side zero- and negative-sequence currents. It shows also how to calculate the non-characteristic harmonics on the VSC ac side.
This work presents compensation algorithm schemes used for shunt active power filters applied to three-phase four-wire systems, allowing harmonic current suppression and reactive power compensation, which results in an effective power factor correction. The strategies used to extract the three-phase reference currents are based on the synchronous reference frame method. Although this method is based on balanced three-phase loads, it can also be used for single-phase loads, allowing independent control of all three phases. Accordingly, a fictitious quadrature current needs to be generated through software implementation, and be orthogonal to the measured load current. This creates the fictitious balanced currents in the two-phase stationary reference frame system, allowing the choice of an adequate compensation strategy which will result in either balanced or unbalanced sinusoidal source currents. Three shunt APF topologies are evaluated under unbalanced load conditions: Split-Capacitor (S-C), Four-Leg (F-L) and Three Full-Bridge (3F-B). The proposed algorithms applied to the three APF topologies are evaluated and discussed. Mathematical analyses of the SRF-based algorithms are presented and simulation results are performed to validate the theoretical development and confirm the performance of the shunt APFs.
About Me
Professor at Federal University of Sao Carlos (UFSCar), Sao Carlos, Brazil.
Professor at Federal University of Sao Carlos (UFSCar), Sao Carlos, Brazil.