Dai-Trang Le

Dr. Dai-Trang Le

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
DLDai-Trang Le
Dai-Trang Le
CDCatherine M. Davis
Catherine M. Davis
KWKevin Wei
Kevin Wei
YZYan Zhao
Yan Zhao
ZCZhiping Cao
Zhiping Cao
SKSanjiv Kaul
Sanjiv Kaul
We hypothesized that ranolazine-induced adenosine release is responsible for its beneficial effects in ischemic heart disease. Sixteen open-chest anesthetized dogs with noncritical coronary stenosis were studied at rest, during dobutamine stress, and during dobutamine stress with ranolazine. Six additional dogs without stenosis were studied only at rest. Regional myocardial function and perfusion were assessed. Coronary venous blood was drawn. Murine endothelial cells and cardiomyocytes were incubated with ranolazine and adenosine metabolic enzyme inhibitors, and adenosine levels were measured. Cardiomyocytes were also exposed to dobutamine and dobutamine with ranolazine. Modeling was employed to determine whether ranolazine can bind to an enzyme that alters adenosine stores. Ranolazine was associated with increased adenosine levels in the absence (21.7 ± 3.0 vs. 9.4 ± 2.1 ng/mL, P < 0.05) and presence of ischemia (43.1 ± 13.2 vs. 23.4 ± 5.3 ng/mL, P < 0.05). Left ventricular end-systolic wall stress decreased (49.85 ± 4.68 vs. 57.42 ± 3.73 dyn/cm2, P < 0.05) and endocardial-to-epicardial myocardial blood flow ratio tended to normalize (0.89 ± 0.08 vs. 0.76 ± 0.10, P = nonsignificant). Adenosine levels increased in cardiac endothelial cells and cardiomyocytes when incubated with ranolazine that was reversed when cytosolic-5′-nucleotidase (cN-II) was inhibited. Point mutation of cN-II aborted an increase in its specific activity by ranolazine. Similarly, adenosine levels did not increase when cardiomyocytes were incubated with dobutamine. Modeling demonstrated plausible binding of ranolazine to cN-II with a docking energy of −11.7 kcal/mol. We conclude that the anti-adrenergic and cardioprotective effects of ranolazine-induced increase in tissue adenosine levels, likely mediated by increasing cN-II activity, may contribute to its beneficial effects in ischemic heart disease. NEW & NOTEWORTHY Ranolazine is a drug used for treatment of angina pectoris in patients with ischemic heart disease. We discovered a novel mechanism by which this drug may exhibit its beneficial effects. It increases coronary venous levels of adenosine both at rest and during dobutamine-induced myocardial ischemia. Ranolazine also increases adenosine levels in endothelial cells and cardiomyocytes in vitro, by principally increasing activity of the enzyme cytosolic-5′-nucleotidase. Adenosine has well-known myocardial protective and anti-adrenergic properties that may explain, in part, ranolazine’s beneficial effect in ischemic heart disease.

24 June 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
DLDai-Trang Le
Dai-Trang Le
YZYan Zhao
Yan Zhao
SKSanjiv Kaul
Sanjiv Kaul
Background: There is persistent coronary vasomotor tone during myocardial ischemia, despite ongoing coronary arteriolar dilatation. The mechanism underlying this vasodilatory tone, which can be unmasked by coronary vasodilators, is unclear. We hypothesized that persistent microvascular resistance during myocardial ischemia occurs at the level of capillaries and may be caused by pericytes. Methods: We studied nine instrumented dogs where coronary blood flow and coronary driving pressure were reduced to half by placement of stenoses. Myocardial blood flow and myocardial blood volume were measured with myocardial contrast echocardiography before and during adenosine administration. In three animals, the heart was perfusion-fixed under these conditions for electron microscopic assessment of capillary and pericyte size. Results: During ischemia, myocardial blood volume decreased and myocardial vascular resistance remained unchanged. Adenosine administration reversed the decline in myocardial blood volume and decreased myocardial vascular resistance. Electron microscopy showed larger capillaries in ischemic beds receiving adenosine than ischemic beds not receiving adenosine. Pericytes in beds receiving adenosine also tended to be larger. Conclusion: Capillaries are the site of persistent vasomotor tone during myocardial ischemia; any other site of vascular regulation (arterioles or venules) cannot explain these myocardial contrast echocardiography findings, which are confirmed on post-mortem electron microscopic examination. The decrease in capillary size is likely caused by pericyte contraction in an attempt to maintain a constant capillary hydrostatic pressure. Adenosine relaxes pericytes, restores myocardial blood volume, reduces myocardial vascular resistance, and improves regional function during ischemia. These findings could have important therapeutic implications.

8 November 2011 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
DLDai-Trang Le
Dai-Trang Le
TBThanjavur Bragadeesh
Thanjavur Bragadeesh
YZYan Zhao
Yan Zhao
YWYue-Gang Wang
Yue-Gang Wang
DZDaogang Zha
Daogang Zha
SKSanjiv Kaul
Sanjiv Kaul
Aims Regadenoson is comparable to adenosine in pharmacologic radionuclide stress tests but has not been studied with stress myocardial contrast echocardiography. This study assessed the haemodynamic profile and ability of regadenoson, a novel selective A2A receptor agonist, to detect coronary artery stenosis during myocardial contrast echocardiography. Methods and results Myocardial contrast echocardiography was performed to measure myocardial blood volume, myocardial blood flow velocity, and total regional myocardial blood flow before and after administration of regadenoson (5 µg kg−1, 10 s bolus) in 10 open-chest dogs with mild-to-moderate coronary stenosis that was not flow limiting at rest. Regadenoson decreased blood pressure but did not change heart rate. It increased coronary blood flow significantly (P < 0.05) for 30 min, which was attenuated in proportion to coronary stenosis severity. Whereas myocardial blood volume maximally increased by 0.5–0.75-fold in the control region, it did not change in the region supplied by the non-flow limiting stenosis. Perfusion defects were visually and quantitatively detectable for as long as 10 min after administration of regadenoson. No arrhythmias were noted with regadenoson either prior to or during myocardial contrast echocardiography. Conclusion Regadenoson can be used as a vasodilator stress agent with myocardial contrast echocardiography to detect the presence of physiologically significant coronary stenosis. The optimum time for image acquisition was 3–10 min after drug administration.

17 June 2024 in The Journal of Physiology
Verified
Journal Article
Closed access
DLDai-Trang Le
Dai-Trang Le
NANabil Alkayed
Nabil Alkayed
ZCZhiping Cao
Zhiping Cao
NCNatasha N. Chattergoon
Natasha N. Chattergoon
MJManuel Garcia Jaramillo
Manuel Garcia Jaramillo
SKSanjiv Kaul
Sanjiv Kaul

12 June 2025 in Current Cardiology Reports
Verified
Journal Article
Closed access
PDF file
PMPristine Mei
Pristine Mei
DCDelia Cotiga
Delia Cotiga
IMIngy Mahana
Ingy Mahana
NGNimra Gilani
Nimra Gilani
MDMichelle L. Dew
Michelle L. Dew
DLDai-Trang Le
Dai-Trang Le

5 August 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
NNNorth J. Noelck
North J. Noelck
HPHeather A Perry
Heather A Perry
PTPhyllis Talley
Phyllis Talley
DLDai-Trang Le
Dai-Trang Le
Background/Objectives: Historically, echocardiographic imaging of the right heart has been challenging because its abnormal geometry is not conducive to reproducible anatomical and functional assessment. With the development of advanced echocardiographic techniques, it is now possible to complete an integrated assessment of the right heart that has fewer assumptions, resulting in increased accuracy and precision. Echocardiography continues to be the first-line imaging modality for diagnostic analysis and the management of acute and chronic right heart failure because of its portability, versatility, and affordability compared to cardiac computed tomography, magnetic resonance imaging, nuclear scintigraphy, and positron emission tomography. Virtually all echocardiographic parameters have been well-validated and have demonstrated prognostic significance. The goal of this narrative review of the echocardiographic parameters of the right heart chambers and hemodynamic alterations associated with right ventricular dysfunction is to present information that must be acquired during each examination to deliver a comprehensive assessment of the right heart and to discuss their clinical significance in right heart failure. Methods: Using a literature search in the PubMed database from 1985 to 2025 and the Cochrane database, which included but was not limited to terminology that are descriptive of right heart anatomy and function, disease states involving acute and chronic right heart failure and pulmonary hypertension, and the application of conventional and advanced echocardiographic modalities that strive to elucidate the pathophysiology of right heart failure, we reviewed randomized control trials, observational retrospective and prospective cohort studies, societal guidelines, and systematic review articles. Conclusions: In addition to the conventional 2-dimensional echocardiography and color, spectral, and tissue Doppler measurements, a contemporary echocardiographic assessment of a patient with suspected or proven right heart failure must include 3-dimensional echocardiographic-derived measurements, speckle-tracking echocardiography strain analysis, and hemodynamics parameters to not only characterize the right heart anatomy but to also determine the underlying pathophysiology of right heart failure. Complete and point-of-care echocardiography is available in virtually all clinical settings for routine care, but this imaging tool is particularly indispensable in the emergency department, intensive care units, and operating room, where it can provide an immediate assessment of right ventricular function and associated hemodynamic changes to assist with real-time management decisions.