Dale R. Wagner

Dr. Dale R. Wagner

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2013 in Journal of Obesity
Verified
Journal Article
Open access
PDF file
Dale R. WagnerDale R. Wagner
Dale R. Wagner
Ultrasound has been used effectively to assess body fat for nearly 5 decades, yet this method is not known as well as many other body composition techniques. The purpose of this review is to explain the technical principles of the ultrasound method, explain the procedures for taking a measurement and interpreting the results, evaluate the reliability and validity of this method for measuring subcutaneous and visceral adipose tissue, highlight the advantages and limitations of ultrasound relative to other body composition methods, consider its utility to clinical populations, and introduce new body composition-specific ultrasound technology. The focus of this review is adipose, although various tissue thicknesses (e.g., muscle and bone) can be measured with ultrasound. Being a portable imaging device that is capable of making fast regional estimates of body composition, ultrasound is an attractive assessment tool in instances when other methods are limited. Furthermore, much of the research suggests that it is reliable, reproducible, and accurate. The biggest limitations appear to be a lack of standardization for the measurement technique and results that are highly dependent on operator proficiency. New ultrasound devices and accompanying software designed specifically for the purpose of body composition assessment might help to minimize these limitations.

1 March 2007 in High Altitude Medicine & Biology
Verified
Journal Article
Closed access
Dale R. WagnerDale R. Wagner
Dale R. Wagner
KTKevin Tatsugawa
Kevin Tatsugawa
DPDaryl Parker
Daryl Parker
TYTroy A. Young
Troy A. Young
Wagner, Dale R., Kevin Tatsugawa, Daryl Parker, and Troy A. Young. Reliability and utility of a visual analog scale for the assessment of acute mountain sickness. High Alt. Med. Biol. 8:27–31, 2007.—Acute mountain sickness (AMS) is a common condition that affects people that ascend too rapidly to high altitude. It is typically assessed with the Lake Louise AMS Self-report Score (LLSelf) that uses a categorical numeric rating scale to answer five questions addressing AMS-related symptoms, such as headache. A 100-mm visual analog scale (VAS) is commonly used to assess subjective phenomena such as pain, but this scale has never been used for the self-assessment of AMS. The purpose of this study was to compare a VAS score to the total LLSelf and to evaluate the test–retest and interrater reliability of the VAS when used as an assessment of AMS. Participants (N = 356) completed both the LLSelf and the VAS on the summit of Mt. Whitney (4419 m). There was a significant relationship (r = 0.65, p < 0.01) between the LLSelf (2.8 ± 2.0, mean ± SD) and the VAS (14.4 ± 14.1 mm). Fifty-seven participants were randomly selected for reliability testing of the VAS. Both test–retest reliability (ICC = 0.996, 95% CI = 0.992 to 0.998) and interrater reliability (ICC = 1.000, 95% CI = 0.999 to 1.000) were high. The mean difference in the VAS score between tests was <1 mm, as was the difference between raters. These results demonstrate excellent reliability for the VAS as an assessment of AMS.

13 April 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Dale R. WagnerDale R. Wagner
Dale R. Wagner
DCDustin L. Cain
Dustin L. Cain
NCNicolas Clark
Nicolas Clark
This study evaluated the validity and reliability of the BodyMetrix™ BX2000 A-mode ultrasound for estimating percent body fat (%BF) in athletes by comparing it to skinfolds and the BOD POD. Forty-five (22 males, 23 females) National Collegiate Athletic Association (NCAA) Division-I athletes volunteered for this study. Subjects were measured once in the BOD POD then twice by two technicians for skinfolds and ultrasound. A one-way repeated-measures ANOVA revealed significant differences between body composition methods (F = 13.24, p < 0.01, η² = 0.24). This difference was further explained by a sex-specific effect such that the mean difference between ultrasound and BOD POD was large for females (~ 5% BF) but small for males (~ 1.5% BF). Linear regression using the %BF estimate from ultrasound to predict %BF from BOD POD resulted in an R2 = 0.849, SEE = 2.6% BF and a TE = 4.4% BF. The inter-rater intraclass correlation (ICC) for skinfold was 0.966 with a large 95% confidence interval (CI) of 0.328 to 0.991. The inter-rater ICC for ultrasound was 0.987 with a much smaller 95% CI of 0.976 to 0.993. Both skinfolds and ultrasound had test-retest ICCs ≥ 0.996. The BX2000 ultrasound device had excellent test-retest reliability, and its inter-rater reliability was superior to the skinfold method. The validity of this method is questionable, particularly for female athletes. However, due to its excellent reliability, coaches and trainers should consider this portable and easy to use A-mode ultrasound to assess body composition changes in athletes.

1 February 2018 in European Journal of Clinical Nutrition
Verified
Journal Article
Closed access
PDF file
Dale R. WagnerDale R. Wagner
Dale R. Wagner
BTBrennan J. Thompson
Brennan J. Thompson
DAD. Andy Anderson
D. Andy Anderson
SSSarah Schwartz
Sarah Schwartz

1 June 2012 in Wilderness & Environmental Medicine
Verified
Journal Article
Closed access
Dale R. WagnerDale R. Wagner
Dale R. Wagner
JKJonathan R. Knott
Jonathan R. Knott
JFJack P. Fry
Jack P. Fry
The purpose of this study was to determine whether arterial oxygen saturation (Spo(2)) and heart rate (HR), as measured by a finger pulse oximeter on rapid arrival to 4260 m, could be predictive of acute mountain sickness (AMS) or summit success on a climb to 5640 m. Climbers (35.0 ± 10.1 years; 51 men, 5 women) were transported from 2650 m to the Piedra Grande hut at 4260 m on Pico de Orizaba within 2 hours. After a median time of 10 hours at the hut, they climbed toward the summit (5640 m) and returned, with a median trip time of 14 hours. The Lake Louise Self-Assessment Scale (LLSS) for AMS, HR, and Spo(2) were collected on arrival at the hut and repeated immediately before and after the climbers' summit attempts. Average Spo(2) for all participants at 4260 m before their departure for the summit was 84.4% ± 3.7%. Thirty-seven of the 56 participants reached the summit, and 59% of all climbers met the criteria for AMS during the ascent. The Spo(2) was not significantly different between those who experienced AMS and those who did not (P = .82); neither was there a difference in Spo(2) between summiteers and nonsummiteers (P = .44). Climbers' HR just before the summit attempt was not related to AMS but was significantly lower for summiteers vs nonsummiteers (P = .04). The Spo(2) does not appear to be predictive of AMS or summit success during rapid ascents.

1 December 2006 in Wilderness & Environmental Medicine
Verified
Journal Article
Closed access
Dale R. WagnerDale R. Wagner
Dale R. Wagner
JFJamison D. Fargo
Jamison D. Fargo
DPDaryl Parker
Daryl Parker
KTKevin Tatsugawa
Kevin Tatsugawa
TYTroy A. Young
Troy A. Young
The interaction of 15 variables representing physical characteristics, previous altitude exposure, and ascent data was analyzed to determine their contribution to acute mountain sickness (AMS). Questionnaires were obtained from 359 volunteers upon reaching the summit of Mt Whitney (4419 m). Heart rate and arterial oxygen saturation were measured with a pulse oximeter, and AMS was identified by Lake Louise Self-Assessment scoring. Multiple logistic regression analysis was used to identify significant protective and risk factors for AMS. Thirty-three percent of the sample met the criteria for AMS. The odds of experiencing AMS were greater for those who reported a previous altitude illness (adjusted odds ratio [OR] = 2.00, P < .01) or who were taking analgesics during the ascent (adjusted OR = 2.09, P < .01). Odds for AMS decreased with increasing age (adjusted OR = 0.82, P < .0001), a greater number of climbs above 3000 m in the past month (adjusted OR = 0.92, P < .05), and use of acetazolamide during the ascent (adjusted OR = 0.33, P < .05). The significant determinants of AMS on the summit of Mt Whitney were age, a history of altitude illness, number of climbs above 3000 m in the past month, and use of acetazolamide and analgesics during ascent.